This study investigates how CT image reconstruction parameters (convolution kernel and iterative reconstruction strength) impact the diagnostic performance of radiomics and deep learning (DL) for classifying lung adenocarcinoma subtypes. The key finding is that DL models are more sensitive to these parameter variations than radiomics, suggesting that standard convolution kernels are generally preferable for imaging analysis.
What Problem Does This Paper Address?
Lung cancer remains a leading cause of cancer-related deaths, making early and accurate diagnosis crucial. Medical imaging, particularly CT scans, plays a vital role in this process. Radiomics, which extracts quantitative features from medical images, and deep learning (DL), a powerful machine learning technique, are emerging as promising tools for improving diagnostic accuracy. However, the performance of both radiomics and DL can be significantly influenced by variations in CT acquisition and reconstruction parameters. This study aims to systematically evaluate how two specific reconstruction parameters – the convolution kernel (bone vs. standard) and the strength of iterative reconstruction (ASiR) – affect the diagnostic performance of radiomics and DL models in classifying lung adenocarcinoma subtypes. Understanding these influences is critical for ensuring the robustness and reproducibility of these AI-driven diagnostic tools in clinical practice, especially given the potential for variations across different imaging centers.
Methods
The researchers employed a multi-faceted experimental approach to assess the impact of CT reconstruction parameters. They utilized three reconstruction algorithms (ASiR at 0%, 30%, and 60% strength) combined with two convolution kernels (bone and standard), resulting in six distinct image reconstruction groups.
For feature extraction, they used the Pyradiomics toolkit to extract a comprehensive set of 1301 radiomic features, encompassing first-order statistics, shape-based features, and various texture features (GLCM, GLRLM, GLSZM, NGTDM, GLDM). To manage the high dimensionality and prevent overfitting, Principal Component Analysis (PCA) was used for dimension reduction, and logistic regression with L2 regularization was employed for model building.
For the deep learning approach, a DenseNets-based multi-task learning framework was utilized. This framework was designed to simultaneously predict lung adenocarcinoma invasiveness (IAC vs. non-IAC) and segment the nodules, with segmentation acting as an auxiliary task to guide the network. The model processed 3D cubic patches of CT data and employed a binary cross-entropy loss for classification and a dice loss for segmentation.
Three experimental designs were implemented:
- Experiment A (Exp_A): Models were trained and tested on data from the same reconstruction group, allowing for direct comparison of performance within each parameter setting.
- Experiment B (Exp_B): Models were trained on a mixed dataset from all six groups and then tested individually on each of the six groups. This assessed the model's ability to generalize across different reconstruction parameters.
- Experiment C (Exp_C): This involved cross-testing, where models trained on one reconstruction group were tested on data from other groups. This was designed to evaluate the generalization ability of the models more rigorously.
Model performance was evaluated using Receiver Operating Characteristic (ROC) curves and Area Under the Curve (AUC) values, with statistical significance determined by DeLong's method (P < 0.05).
Datasets
The study utilized a dataset of 215 pathologically confirmed lung adenocarcinomas from 183 patients. These nodules were categorized into four subtypes: atypical adenomatous hyperplasia (AAH), adenocarcinomas in situ (AIS), minimally invasive adenocarcinomas (MIA), and invasive adenocarcinomas (IAC).
Due to the imbalanced distribution of these subtypes, the researchers grouped AAH, AIS, and MIA into a single "non-IAC" class for binary classification (IAC vs. non-IAC). The dataset was divided into a training/validation set of 171 nodules and a testing set of 44 nodules. All CT imaging data was acquired using a single GE Discovery CT750 HD scanner.
Key Insights and Ideas
- DL is More Susceptible to Reconstruction Variability: The most striking finding is that deep learning models showed significantly more performance variation across different CT reconstruction parameters compared to radiomics models. This suggests that DL algorithms are more sensitive to the subtle changes introduced by convolution kernels and iterative reconstruction strengths.
- Standard Convolution Kernels Shine: Standard convolution kernels consistently outperformed bone convolution kernels for deep learning models across all ASiR levels. This indicates that smoother image reconstruction, which reduces noise and spatial resolution, is generally more beneficial for DL-based analysis in this context.
- Radiomics Shows Greater Robustness: Radiomics models demonstrated more stable performance across the tested reconstruction parameters, with fewer statistically significant differences observed, particularly in the initial experiments. This implies that radiomics features are less affected by these specific CT reconstruction variations.
- The "Why" Behind DL's Sensitivity: The authors speculate that DL networks, by learning higher-level representations, might be more easily confused or misled by the increased noise and potentially artificial textures introduced by bone convolution kernels. Standard kernels, by reducing noise, may allow DL to learn more discriminative and generalizable features.
- Cross-Testing Reveals Generalization Differences: Experiment C, which involved cross-testing, highlighted the differences in generalization ability. While radiomics models trained on bone kernels sometimes outperformed DL models, standard kernel DL models showed greater stability and generalization, especially when tested on data from different reconstruction groups.
Key Results
- Experiment A & B: In Exp_A, no statistically significant differences were found for radiomics, while DL showed significant differences in two pairs. In Exp_B, radiomics again showed no significant differences, but DL exhibited significant differences in six pairs.
- Experiment C: This experiment revealed more pronounced differences. Radiomics showed significant differences in one model, while DL showed them in four models. Standard convolution kernel data consistently led to better performance in DL models compared to bone convolution kernel data. Specifically, models trained on S60 (standard kernel, 60% ASiR) performed best in the DL method.
- AUC Values: While specific AUC values varied across experiments and models, the general trend indicated that radiomics models often achieved higher AUCs than DL models in Exp_A and Exp_B. However, in Exp_C, DL models trained on standard kernels showed strong and stable performance, sometimes outperforming radiomics. For instance, in Exp_C, DL models trained on S60 achieved AUCs around 0.90-0.91, while radiomics models on S60 achieved AUCs around 0.88-0.90.
Limitations and Future Work
- Sample Size: The authors acknowledge that the sample size, while considered acceptable and larger than some previous studies, might be insufficient for perfectly training the DL models, potentially leading to overfitting and instability. They emphasize the need for larger datasets to improve reproducibility and generality.
- Data Imbalance: The pathological subtypes were imbalanced, which was addressed by grouping less common subtypes. However, this simplification might have masked subtle differences.
- Single Scanner: The study used data from a single scanner manufacturer (GE). Variability across different manufacturers' reconstruction algorithms was not investigated.
- Future Work: The authors suggest further investigation with larger sample sizes and data from multiple manufacturers to confirm their findings and provide a more comprehensive understanding of CT parameter influences on radiomics and DL performance. They also highlight the need for more research to understand the underlying reasons for DL's sensitivity to these parameters.
Summary updated