Contouring lumbosacral plexus nerves with MR neurography and MR/CT deformable registration technique

Xi Cao, Xianshu Gao, Wei Li, Peilin Liu, Shangbin Qin, Yan-Bin Dou, Hongzhen Li, Shiyu Shang, Xiaobin Gu, Mingwei Ma, Xin Qi, Mu Xie, Dian WangFrontiers in Oncology 2022 · DOI

TL;DR

This paper introduces a novel approach using specialized MR neurography (MRN) sequences combined with MR/CT deformable registration to accurately contour the lumbosacral plexus (LSP) nerves. This improved contouring is crucial for precise radiation dose assessment in cancer patients, potentially reducing the risk of treatment-induced neuropathy.

What Problem Does This Paper Address?

Accurately delineating the lumbosacral plexus (LSP) nerves for radiation therapy planning is challenging. Standard CT scans lack the resolution and contrast to clearly distinguish these delicate nerve structures from surrounding soft tissues. While MRI offers better visualization, traditional MRI sequences are also insufficient for precise nerve identification. This difficulty in contouring means that radiation oncologists may struggle to accurately assess the dose delivered to the LSP, potentially leading to an increased risk of radiation-induced lumbosacral plexopathy (RILSP), a debilitating condition causing pain, numbness, and weakness in the lower extremities. The paper aims to address this by identifying an optimal MRN sequence and a robust registration technique to enable precise LSP contouring.

Methods

The study employed a two-pronged approach:

  1. MR Neurography (MRN) Sequence Optimization: Two MRN sequences, Lr_NerveVIEW and Cs_NerveVIEW, were developed by optimizing a published 3D NerveVIEW sequence. The Lr_NerveVIEW sequence is a heavy T2-weighted fast spin-echo sequence with a voxel size of 1.22 mm x 1.25 mm x 2.00 mm, utilizing short tau inversion recovery for fat suppression and motion-sensitized driven-equilibrium for blood flow suppression. The Cs_NerveVIEW sequence further reduced the voxel size to 1.0 mm isotropically, employing spectral attenuated inversion recovery and compressed sensing to maintain signal-to-noise ratio and reduce scan time.
  2. MR/CT Deformable Registration: The best-performing MRN sequence was then fused with simulation CT images using a deformable registration technique. This method accounts for potential positional and shape variations between the CT and MR scans, ensuring accurate alignment. The fused images were used to delineate the LSP nerves.

The nerve visualization ability of the two MRN sequences was initially evaluated in 10 patients using a four-point Nerve Visualization Score (NVS). The sequence with superior visualization was then used for the remaining participants.

Datasets

The study utilized data from:

  • 18 patients diagnosed with prostate cancer who underwent radiation therapy to the pelvis.
  • 1 volunteer with radiation-induced lumbosacral plexopathy (RILSP).

These participants provided simulation CT images, original treatment plans, and MRN images. The study did not introduce a new benchmark dataset but rather evaluated existing imaging modalities and registration techniques on a clinical patient cohort.

Key Insights and Ideas

  • MRN's Superiority for Nerve Visualization: MR neurography, particularly the Lr_NerveVIEW sequence, significantly outperforms traditional MRI sequences in visualizing the complex anatomy of the lumbosacral plexus. This is attributed to its ability to suppress background signals (fat, blood flow) and enhance nerve contrast.
  • Deformable Registration is Key: Combining MRN with MR/CT deformable registration is crucial for accurate LSP contouring. Rigid registration is insufficient due to potential patient positioning shifts between scans. Deformable registration ensures precise alignment, allowing for reliable delineation of the LSP on fused images.
  • Potential for Reduced RILSP: The ability to accurately contour the LSP opens the door to more precise dose assessment and potentially sparing these critical structures during radiation therapy. This could lead to a reduction in the incidence and severity of RILSP.
  • Personalized Contouring: The developed method allows for personalized contouring of the LSP, focusing only on the relevant nerve structures for a specific patient's treatment, rather than requiring contouring of the entire plexus.

Key Results

  • Lr_NerveVIEW Outperforms Cs_NerveVIEW: The Lr_NerveVIEW sequence achieved significantly higher Nerve Visualization Scores (NVS) compared to the Cs_NerveVIEW sequence (p=0.004), indicating superior nerve visualization.
  • Successful LSP Contouring: The MRN/CT deformable registration technique successfully created LSP structures in all 19 participants (18 patients and 1 volunteer), conforming to anatomical distribution.
  • Dosimetric Findings: In the patient cohort, a significant percentage of patients received doses exceeding 50 Gy (68%), 55 Gy (33%), and 60 Gy (17%) to their LSP nerves. When excluding patients who did not receive prophylactic whole-pelvic radiotherapy, these percentages increased to 92%, 46%, and 23%, respectively.
  • Volunteer Case: The volunteer with RILSP received a maximum dose of 69 Gy to their LSP nerves.

Limitations and Future Work

  • Lack of Direct Comparison with Traditional MRI: The study did not include a direct comparison with traditional MRI sequences, relying on clinical experience and impression for superiority claims.
  • Economic Burden: The additional cost of MRN examinations may limit its widespread adoption in routine clinical practice.
  • Resolution Limitations: Even with Lr_NerveVIEW, the resolution may not be sufficient to assess very small nerve branches, and further advanced imaging techniques (e.g., gadolinium contrast agents) might be needed.
  • Small Patient Cohort: The study involved a relatively small number of patients.
  • Hypofractionated Radiation: The enrolled patients received moderately hypofractionated radiation therapy. While the contouring method is applicable to SBRT, further studies with SBRT cases are needed to confirm its superiority in that context.

Future work should focus on incorporating this MRN-based contouring into SBRT protocols and investigating the correlation between LSP dose and clinical outcomes, particularly RILSP development.

Summary updated

Abstract

The Lr_NerveVIEW MRN sequence performed better than the Cs_NerveVIEW sequence in nerve visualization. The dose in the LSP needs to be measured to understand the potential impact on treatment-induced neuropathy.
BibTeX
@inproceedings{cao2022contouring,
  author = {Xi Cao and Xianshu Gao and Wei Li and Peilin Liu and Shangbin Qin and Yan-Bin Dou and Hongzhen Li and Shiyu Shang and Xiaobin Gu and Mingwei Ma and Xin Qi and Mu Xie and Dian Wang},
  title = {{Contouring lumbosacral plexus nerves with MR neurography and MR/CT deformable registration technique}},
  booktitle = {Frontiers in Oncology},
  year = {2022},
  doi = {10.3389/fonc.2022.818953},
}
Figure