Abstract
Animal Assisted Interactions (AAIs) provide significant psychological benefits, yet objective physiological monitoring remains challenging due to the limitations of wearable sensors. This paper presents a non-contact system using standard RGB cameras to simultaneously estimate human heart rate (HR) and canine breathing rate (BR). By employing remote photoplethysmography (rPPG) for humans and motion-based tracking for canines, integrated with an Adaptive Multi-Trace Carving (AMTC) algorithm, the system achieves high accuracy even during active interactions.
Introduction
Animal Assisted Interactions (AAIs), such as therapy dog sessions, are widely recognized for reducing stress and improving well-being. However, quantifying these benefits objectively is difficult. Traditional research relies on subjective surveys or invasive wearable sensors. Wearables are often uncomfortable for humans and often require shaving a dog's fur or using subdermal inserts, which can disrupt the natural flow of interaction. Furthermore, motion artifacts—noise generated by movement—frequently degrade signal quality. This study addresses these challenges by proposing a non-contact, objective monitoring system suitable for naturalistic settings.
Methodology
The proposed system utilizes a dual-pipeline approach powered by consumer-grade RGB cameras to monitor physiological signals without physical contact.
Human Heart Rate Estimation
The system employs remote photoplethysmography (rPPG) to detect subtle, periodic variations in skin color caused by the cardiac cycle. To maintain a lock on the subject during movement, Global Motion Aggregation (GMA), a deep-learning-based optical flow algorithm, tracks skin regions such as the face, hands, or legs across video frames.
Canine Breathing Rate Estimation
Because fur prevents the use of rPPG on dogs, the system instead tracks the physical motion of the dog’s belly. The subtle rise and fall associated with respiration are captured through spatial displacement computation.
Signal Processing and AMTC
Both human and canine signals undergo rigorous preprocessing, including detrending to remove slow drifts and clipping to eliminate sudden spikes from large movements. The core of the frequency extraction is the Adaptive Multi-Trace Carving (AMTC) algorithm. AMTC is uniquely capable of tracking multiple frequency traces simultaneously, allowing it to distinguish between a dog's breathing and external rhythmic motions, such as a human patting the dog.
Experimental Setup
A proof-of-concept study was conducted with two adult humans and two dogs (a Shih-Tzu and a Corgi). Ground truth data were collected using medical-grade wearables: an Empatica E4 wristband and ECG chest patch for humans, and custom 3D-printed electrodes and a sensing vest for dogs. Video data were captured using a standard 0.3-megapixel HD camera situated in a laptop bezel.
Results and Discussion
The vision-based system demonstrated high accuracy compared to the reference devices:
- Canine Breathing Rate: Achieved a Root Mean Squared Error (RMSE) of 2.9 bpm and a Mean Relative Error (MeRate) of 6.4%.
- Human Heart Rate: Achieved an RMSE of 5.2 bpm and a MeRate of 5.1%.
A key insight was the effectiveness of AMTC in separating overlapping signals. For instance, the algorithm successfully "carved" out the canine breathing rate even when a human was actively petting the dog at a different frequency. Additionally, GMA proved superior to other optical flow methods like RAFT for tracking regions of interest during dynamic interactions.
Limitations and Future Work
While successful for canine breathing, the system still struggles with canine heart rate due to the "fur barrier," which currently necessitates shaving for remote HR detection. Environmental factors like lighting and camera angle also impact rPPG accuracy. Future research will focus on larger, more diverse subject groups and multi-camera setups to improve robustness in high-motion scenarios.
Conclusion
This research demonstrates the feasibility of using non-contact, camera-based systems for simultaneous physiological monitoring in AAIs. By eliminating the need for cumbersome wearables, this approach enables more naturalistic and objective studies of the human-animal bond.
Summary updated