NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

Consensus, dissensus and synergy between clinicians and specialist foundation models in radiology report generation

Ryutaro Tanno, David Barrett, Andrew Sellergren, Sumedh Ghaisas, Sumanth Dathathri, Abigail See, Johannes Welbl, K. K. Singhal, Shekoofeh Azizi, Tao Tu, Mike Schaekermann, R. May, Roy Lee, SiWai Man, Zahra S. Ahmed, S. Sara Mahdavi, Yossi Matias, Joëlle Barral, Ali Eslami, Danielle Belgrave, Vivek Natarajan, Shravya Shetty, Pushmeet Kohli, Po-Sen Huang, Alan Karthikesalingam, Sofia Ira KtenaResearch Square 2024

Abstract

Radiology reports are an instrumental part of modern medicine, informing key clinical decisions such as diagnosis and treatment. The worldwide shortage of radiologists, however, restricts access to expert care and imposes heavy workloads, contributing to avoidable errors in report delivery. While recent progress in automated report generation with vision-language models offers clear potential to ameliorate this situation, the path toward real-world adoption has been stymied by the challenge of evaluating the clinical quality of AI-generated reports. In this study, we build a state-of-the-art report generation system for chest radiographs, Flamingo-CXR, by fine-tuning a well-known vision-language foundation model on radiology data. To measure the quality of the AI-generated reports, we perform an expert evaluation, that is largest in scale and diversity to date, by engaging a group of 27 certified radiologists in the United States and India to provide detailed assessment of AI-generated and human written reports from an intensive care setting as well as an inpatient setting. We observe a wide distribution of preferences across the panel, ranging from full consensus to dissensus, across clinical settings and regions, with 55.4% of Flamingo-CXR intensive care reports evaluated to be preferable or equivalent to clinician reports, by half or more of the panel, rising to 77.7% for outpatient x-rays overall and to 94% for the subset of cases with no pertinent abnormal findings. For reports that contain errors we develop an assistive setting, the first demonstration of clinician-AI collaboration for radiology report composition, and we observe a synergistic improvement across all clinical settings. Altogether, these nuanced evaluations reveal disparities between the AI system and radiologists, identify areas for potential clinical utility and pave the way toward a collaborative system that enhances clinical accuracy of radiology reporting.

Introduction

Radiology serves as the diagnostic backbone of modern healthcare, yet a global shortage of specialists has created a bottleneck in patient care. While automated report generation using vision-language models (VLMs) presents a promising solution, the field faces two significant hurdles: the inadequacy of standard AI metrics (like BLEU or CIDEr) for clinical accuracy and the "ground truth fallacy," which assumes human-written reports are infallible. This study introduces Flamingo-CXR, a state-of-the-art system designed to bridge these gaps through rigorous expert evaluation and clinician-AI collaboration.

Methodology: Beyond Standard Metrics

Flamingo-CXR was developed by fine-tuning the Flamingo foundation model on extensive radiology datasets, leveraging general-purpose knowledge transfer. To evaluate its clinical utility, the researchers implemented a multi-faceted human evaluation framework involving 27 radiologists from the US and India.

Overview of the three-pronged evaluation framework: pairwise preference, error correction, and clinician-AI collaboration.

The evaluation focused on three primary axes:

  1. Pairwise Preference: Blinded comparison between AI and human reports.
  2. Error Correction: Detailed categorization of clinical errors (e.g., location, severity).
  3. Assistive Collaboration: Testing a workflow where clinicians edit AI-generated drafts.

The model was tested on two diverse datasets: MIMIC-CXR (US intensive care) and IND1 (Indian inpatient setting), ensuring geographical and clinical diversity.

Key Findings: The Reality of Expert Dissensus

A pivotal discovery was the prevalence of "dissensus" among experts. Radiologists often disagreed on report quality, particularly in complex cases. While 76% of normal cases reached consensus in the IND1 dataset, complex findings frequently split the panel.

Furthermore, the study identified complementary error patterns. Humans occasionally miss subtle findings due to "satisfaction of search," whereas AI models like Flamingo-CXR may struggle with precise counting (e.g., pacemaker leads) or complex spatial reasoning.

Results and the Power of Synergy

Flamingo-CXR significantly outperformed previous benchmarks, achieving a 33% improvement in CheXpert F1 scores over R2GenGPT. In human evaluations:

  • 55.4% of AI reports in the US intensive care setting were rated equal to or better than human reports by at least half the panel.
  • This figure rose to 77.7% in the Indian inpatient setting and 94% for normal scans.

The most compelling results emerged from the clinician-AI collaboration experiments.

The clinician-AI collaboration workflow, where an expert edits an AI draft to produce a superior final report.

When clinicians edited AI drafts, the resulting reports were preferred over standalone human reports in 71.2% of cases (up from 51.2% for standalone AI). This synergy suggests that AI's most immediate value is as a "high-quality first drafter," reducing cognitive load and improving final accuracy.

Limitations and Future Outlook

While Flamingo-CXR marks a significant advance, limitations remain. The model's 1-megapixel resolution is lower than the 4-megapixel standard used by radiologists, potentially obscuring fine details. Additionally, the AI currently lacks access to broader patient history and prior scans—context that human radiologists use daily. Future work will focus on integrating multi-modal context and improving the user experience for collaborative reporting tools to ensure AI-assisted workflows feel natural and efficient.

Summary updated

BibTeX
@inproceedings{tanno2024consensus,
  author = {Ryutaro Tanno and David Barrett and Andrew Sellergren and Sumedh Ghaisas and Sumanth Dathathri and Abigail See and Johannes Welbl and K. K. Singhal and Shekoofeh Azizi and Tao Tu and Mike Schaekermann and R. May and Roy Lee and SiWai Man and Zahra S. Ahmed and S. Sara Mahdavi and Yossi Matias and Joëlle Barral and Ali Eslami and Danielle Belgrave and Vivek Natarajan and Shravya Shetty and Pushmeet Kohli and Po-Sen Huang and Alan Karthikesalingam and Sofia Ira Ktena},
  title = {{Consensus, dissensus and synergy between clinicians and specialist foundation models in radiology report generation}},
  booktitle = {Research Square},
  year = {2024},
  doi = {10.21203/rs.3.rs-3940387/v1},
}
Figure