Introduction
The Muonium-to-Antimuonium Conversion Experiment (MACE) is a proposed high-precision search for the spontaneous conversion of muonium ($e^-\mu^+$) into antimuonium ($e^+\mu^-$). This process violates the Standard Model (SM) by changing lepton flavor by two units ($|\Delta L| = 2$). While neutrino oscillations have confirmed flavor violation in the neutral sector, Charged Lepton Flavor Violation (cLFV) remains unobserved in the charged sector. MACE aims to improve current sensitivity limits by two orders of magnitude, probing new physics at the 10–100 TeV scale.
Physics Motivation
In the Standard Model, lepton flavor is a conserved quantity. However, many "Beyond the Standard Model" (BSM) theories—including those involving heavy Majorana neutrinos, flavored gauge bosons ($Z'$), and doubly charged Higgs bosons—predict $M-\bar{M}$ oscillations.
Unlike $|\Delta L| = 1$ processes such as $\mu \to e\gamma$, muonium conversion is sensitive to a distinct class of effective operators in the Standard Model Effective Field Theory (SMEFT) framework. This makes MACE complementary to other cLFV searches; even if experiments like Mu3e or MEG II yield null results, MACE could still uncover new physics. The current experimental limit was established by the MACS experiment at PSI in 1999. MACE seeks to push the conversion probability sensitivity down to $\mathcal{O}(10^{-13})$.
Experimental Methodology
MACE utilizes high-intensity surface muon beams from upcoming facilities like the China initiative Accelerator Driven System (CiADS). The experimental setup is designed to identify the unique signature of antimuonium decay: a "fast" Michel electron (tens of MeV) and a "slow" positron ($\sim 13.5$ eV).
Key Subsystems
- Muon Production: Muons strike a perforated silica aerogel target, maximizing the diffusion of muonium atoms into a vacuum. Simulations suggest a multi-layer target could increase yield by a factor of 3.45.
- Michel Electron Magnetic Spectrometer (MMS): A cylindrical drift chamber and timing counters within a 0.1 T magnetic field measure the fast decay electron's momentum. This field strength is optimized to balance spectrometer resolution with the suppression of conversion probability.
- Positron Transport System (PTS): A novel "S-shaped" transport solenoid guides slow positrons to a detector. The S-shape acts as a momentum filter, effectively suppressing high-energy background positrons.
- Positron Detection System (PDS): A Microchannel Plate (MCP) detects the positron's position, while an Electromagnetic Calorimeter (ECAL) identifies the characteristic 511 keV annihilation gamma rays.
The entire system is supported by "Mustard," a C++20 and Geant4-based software framework optimized for high-throughput parallel simulation on the Tianhe-2 supercomputer.
Key Results and Discovery Potential
Simulations indicate that MACE can reach a Single Event Sensitivity (SES) of $1.3 \times 10^{-13}$. This represents a significant leap over previous experiments, allowing for the exploration of new physics scales ($\Lambda$) up to 100 TeV.
The total signal selection efficiency is estimated at 6.6%, accounting for geometric acceptance and reconstruction cuts. By requiring a coincidence between the fast electron and the slow positron, physical backgrounds (such as internal conversion $\mu^+ \to e^+e^-e^+\nu\bar{\nu}$) are suppressed to less than one event per year.
Conclusion and Future Outlook
MACE represents a frontier experiment in the search for charged lepton flavor violation. While its success depends on the commissioning of high-intensity muon sources like CiADS or SHINE, the conceptual design provides a robust path toward order-of-magnitude improvements in sensitivity. Future work will focus on refining target engineering and validating detector performance through a Phase-I pilot run, which will search for $M \to \gamma\gamma$ and $\mu \to e\gamma\gamma$ as calibration benchmarks.
Summary updated