Abstract
Fetal motion discernment utilizing spectral images extracted from accelerometric data incident on pregnant mothers' abdomen has gained substantial attention in state-of-the-art research. It is an essential practice to avoid adverse scenarios such as stillbirths and intrauterine growth restrictions. However, this endeavor of ensuring fetus safety has been arduous due to the existence of random noise in medical images. This novel research is an in-depth approach to analyze how the interference of different noise variations affects the retrieval of information in those images. For that, an algorithm employing auto-encoder-based deep learning was modeled and the accuracy of reconstruction of the STFT images mitigating the noise has been measured examining the loss. From the results, it is manifested that even a substantial addition of the Super-Gaussian noises which have a higher correlation of the frequencies possessed by the Fetal movement images can be restored successfully with the slightest error.
Introduction
Monitoring fetal movement is a critical, non-invasive method for tracking health and preventing outcomes like stillbirth or intrauterine growth restriction. While wearable accelerometers offer a safe, low-cost solution, the resulting data is often obscured by noise from maternal breathing, walking, and electronic interference. This high signal-to-noise ratio makes accurate detection difficult. This study addresses the fundamental challenge of denoising these signals to enable reliable monitoring.
Methodology
The researchers developed a multi-stage pipeline to isolate fetal movement signals from background noise. The process begins with converting raw 1D accelerometric data into 2D spectrograms using the Short-Time Fourier Transform (STFT). These images are then processed by a Convolutional Denoising Auto-Encoder (CDAE). The CDAE consists of an encoder that compresses the noisy image into a bottleneck representation and a decoder that reconstructs the clean signal.
The model was rigorously tested against various noise distributions, including Gaussian white noise, colored noise, and non-Gaussian variations (Sub-Gaussian and Super-Gaussian), to simulate complex real-world environments.
Data and Signal Characteristics
The study utilized a dataset of tri-axial accelerometer and gyroscope recordings from 13 pregnant women. Analysis revealed that fetal movement is most prominent in the Z-axis (perpendicular to the abdomen), which provides the clearest signal for denoising.
Focusing on this specific axis allows for a clearer signal-to-noise ratio before the denoising process begins.
Results and Discussion
The CDAE demonstrated exceptional performance in reconstructing clean signals. Key findings include:
- Optimal Performance: The lowest reconstruction loss was achieved at a Noise Factor of 0.3.
- Super-Gaussian Robustness: The model was particularly effective at handling Super-Gaussian noise (e.g., Laplace or Logistic distributions). Since real-world fetal signals often exhibit similar statistical properties, this suggests the model is well-suited for clinical applications.
- Accuracy: Average minimum reconstruction loss remained extremely low (0.0032 to 0.0038), indicating that the denoised images were nearly identical to the ground truth.
Conclusion
This research proves that deep-learning-based auto-encoders can effectively strip complex noise from fetal movement spectrograms. While the current study used a limited dataset and synthetic noise, the results provide a strong foundation for future real-time monitoring systems. The next step involves integrating this denoising stage with automated classifiers to improve the accuracy of fetal health diagnostics in clinical settings.
Summary updated