Comparison of Template-Based Versus CT-Based Attenuation Correction for Hybrid MR/PET Scanners

Elena Rota Kops, Hubertus Hautzel, Hans Herzog, Gerald Antoch, N. Jon ShahIEEE Transactions on Nuclear Science 2015 · DOI

Abstract

Attenuation correction (AC) of cerebral PET data acquired in hybrid MR/PET scanners is still a challenge. To overcome this problem we previously proposed a correction method by obtaining template-based attenuation maps (AM) using MR and ECAT EXACT HR+ transmission scans. In the present study we investigated (a) the basic difference between template-based and CT-based AC methods and (b) their influence on reconstructed PET images. The data of 11 subjects undergoing <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">18</sup> FDG imaging in the Siemens 3T MR-BrainPET scanner were used. Additionally, from all participants a CT scan of the whole head was acquired at the same day. These CT images were transformed to CT-based AMs. They were filtered by a 3D Gaussian kernel with 3 mm (BrainPET resolution) filter width, which was considered as reference. Comparisons between both AMs (CT-based and template-based) were performed by estimating the Dice coefficients D and calculating the numbers of true positive, true negative and false negative voxels. The BrainPET emission data were reconstructed with both AMs ( AMCT3mm and AMTemplate). All reconstructed PET images were scaled to standardized uptake values (SUVs) and normalized to the MNI brain for using the AAL-VOI Atlas analysis. Correlation plots with regression equation, coefficients of determination R <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> and relative differences (RD) between AMCT3mm and the AMTemplate were derived. The fraction of the overall true positive voxels averaged over the 11 subjects was 80.4 ±7.5% for AMTemplate compared to AMCT3mm ( Dbone = 0.63 ±0.08; Dsoft - tissue = 0.85 ±0.08; Dair = 0.79 ±0.04). A misclassification of bone as soft tissue and vice versa was evident in the comparison. The correlation plot of all VOIs considered (1,276 values) showed a mean R <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> of 0.964 and a slope of 1.02. A mean RD of 1.33 ±0.95% ( min = - 0.12%, max = 2.85%) was found. The template-based AC method proposed by our group shows considerable differences in comparison to the higher resolution CT-based AM with respect to the Dice coefficients, in particular in the classification of bone and soft tissue. However, this has no major influence on the reconstructed <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">18</sup> FDG PET data.
BibTeX
@article{kops2015comparison,
  author = {Elena Rota Kops and Hubertus Hautzel and Hans Herzog and Gerald Antoch and N. Jon Shah},
  title = {{Comparison of Template-Based Versus CT-Based Attenuation Correction for Hybrid MR/PET Scanners}},
  journal = {IEEE Transactions on Nuclear Science},
  year = {2015},
  doi = {10.1109/tns.2015.2452574},
}

Loading related content...

Figure