Comparison of local SAR and temperature increase between 1.5T and 3T in fetal MRI across five numerical pregnant body models
Lists
Only you see this
Abstract
3T can improve fetal MRI compared to 1.5T, but concerns over increased RF safety risk for the fetus exist due to higher field nonuniformity. Previous studies comparing fetal SAR between two field strengths used either a single pregnant body model or artificial pregnant body models. In this study, we compare SAR and temperature increase in the fetus and mother at 1.5T and 3T using 5 anatomically realistic and diverse pregnant body models. Across these models, we find similar or lower levels of fetal SAR and temperature increase at 3T compared to 1.5T.
BibTeX
@inproceedings{yetisir2023comparison,
author = {Filiz Yetişir and Esra Abacı Türk and Judy A. Estroff and Carol E. Barnewolt and Elfar Adalsteinsson and P. Ellen Grant and Lawrence L. Wald},
title = {{Comparison of local SAR and temperature increase between 1.5T and 3T in fetal MRI across five numerical pregnant body models}},
booktitle = {Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition},
year = {2023},
doi = {10.58530/2022/0811},
}Loading related content...