Comparison of Full-Area Simulation Method and Separated Simulation Method of Motor Temperature Field
Abstract
Abstract Permanent magnet motor has become the main research direction of high power density motor, and the heat dissipation capability of the motor has become an important factor restricting the increase of motor power density. High-power density motor generates higher temperature when it works, and high temperature may cause motor insulation burnout, even irreversible demagnetization of permanent magnets. Therefore, thermal analysis and optimal design of cooling structure are very important for high power density motors. In this paper, a 3-D model of thermal simulation of permanent magnet motor is established, and the temperature field is calculated by two methods. 1. The fluid-solid coupling method is used to calculate the global temperature field of the motor and the cooling structure. 2. The fluid-solid coupling method is used to calculate the convective heat transfer coefficient of the cooling structure, then the heat transfer model is used to calculate the temperature field of the motor body. These two methods are introduced and compared in this paper, and the second method is considered to be well suited for optimal design of motor cooling structures.
BibTeX
@article{wang2019comparison,
author = {Wenjie Wang and Shuangfu Suo and Jinshun Hao and Yang Wang},
title = {{Comparison of Full-Area Simulation Method and Separated Simulation Method of Motor Temperature Field}},
journal = {Journal of Physics Conference Series},
year = {2019},
doi = {10.1088/1742-6596/1325/1/012184},
}Ask Althea to put this paper to the test.