Comparison between Deep-Learning-Based Ultra-Wide-Field Fundus Imaging and True-Colour Confocal Scanning for Diagnosing Glaucoma

Younji Shin, Hyunsoo Cho, Yong Un Shin, Mincheol Seong, Jun Won Choi, Won June LeeJournal of Clinical Medicine 2022

TL;DR

This study investigates the diagnostic capabilities of two advanced fundus imaging techniques, ultra-wide-field (UWF) and true-colour confocal scanning, for glaucoma detection using deep learning (DL). The findings suggest that both imaging modalities, when analyzed with DL, offer comparable and effective diagnostic performance, rivaling traditional OCT-based methods.

What Problem Does This Paper Address?

Glaucoma is a chronic, progressive optic nerve disease that can lead to irreversible vision loss. Early diagnosis is crucial for preventing severe visual impairment, but it's challenging because symptoms often appear late. Detecting subtle changes in the retinal nerve fiber layer (RNFL) is a key indicator for early glaucoma detection. While various imaging methods exist, integrating them for diagnosis can be complex. This paper addresses the need for more efficient and accurate glaucoma diagnosis by evaluating two relatively new, high-resolution fundus imaging techniques – UWF and true-colour confocal scanning – and assessing their performance when augmented with deep learning. The goal is to determine if these modern imaging systems, powered by AI, can provide reliable diagnostic capabilities comparable to established methods.

Methods

The researchers employed a retrospective, comparative study design. They utilized a Convolutional Neural Network (CNN), specifically the VGG-19 architecture, for image recognition tasks. This network was chosen for its popularity and computational efficiency. The VGG-19 model was trained to classify images as either indicative of glaucoma or normal.

Two distinct imaging modalities were used as input for the DL models:

  1. Ultra-Wide-Field (UWF) Fundus Imaging: This technique captures a broad view of the retina using red and green lasers, allowing for rapid imaging of peripheral areas without pupil dilation.
  2. True-Colour Confocal Scanning: This method uses a white light-emitting diode (LED) to acquire high-resolution images of the retina.

The DL models were trained on a dataset of 545 images and tested on 232 images. The diagnostic performance was evaluated using standard metrics: Area Under the Receiver Operating Characteristic Curve (AUC) and accuracy. The study also compared the performance of these DL-based methods against traditional glaucoma diagnostic parameters derived from Optical Coherence Tomography (OCT), such as RNFL, ganglion cell-inner plexiform layer (GCIPL), and ganglion cell complex (GCC) thickness.

Datasets

The study utilized a dataset comprising 777 eyes, consisting of 273 normal control eyes and 504 glaucomatous eyes. This dataset was split into a training set of 545 images and a test set of 232 images at a 7:3 ratio. The data was collected retrospectively from patients who visited the glaucoma clinic at Hanyang University Hospital between August 2019 and August 2021.

Key Insights and Ideas

  • DL Bridges the Gap: Deep learning appears to be a powerful tool for extracting diagnostic information from advanced fundus imaging, potentially overcoming limitations of manual interpretation.
  • UWF vs. Confocal: A DL Perspective: While previous studies suggested differences in manual interpretation between UWF and true-colour confocal imaging for RNFL defects, this study shows that with DL, both modalities achieve comparable diagnostic performance.
  • High-Resolution Imaging is Key: Both UWF and true-colour confocal scanning, with their ability to capture detailed retinal structures, show promise when combined with DL for glaucoma screening.
  • AI as a Diagnostic Aid: The study reinforces the idea that AI-powered analysis of fundus images can be a valuable adjunct to traditional diagnostic methods, potentially improving efficiency and accuracy in clinical settings.

Key Results

  • UWF Fundus Imaging (DL-based): Achieved an accuracy of 83.62% and an AUC of 0.904 (95% CI: 0.861–0.937).
  • True-Colour Confocal Scanning (DL-based): Achieved an accuracy of 81.46% and an AUC of 0.868 (95% CI: 0.824–0.912).
  • Comparison: The study found no significant difference in the diagnostic ability between DL-based UWF fundus imaging and DL-based true-colour confocal scanning (p = 0.135).
  • Comparison to OCT: Both DL-based imaging modalities showed comparable diagnostic performance to traditional OCT parameter-based methods (RNFL, GCIPL, GCC), with no significant differences observed (all p > 0.05).

Limitations and Future Work

The authors acknowledge several limitations:

  • No Direct Physician Comparison: The study did not directly compare the DL algorithm's performance with that of human glaucoma specialists. Instead, it compared DL with established OCT parameters.
  • Limited Image Modalities: Conventional fundus images or red-free images were not available for direct comparison, which could be a disadvantage as red-free images are often considered a gold standard for RNFL defect assessment.
  • Age Differences: A statistically significant age difference was observed between the glaucoma and normal groups, which could potentially influence results, although the authors note that the DL analysis and the lack of significant difference between training and test datasets mitigate this concern.
  • Data Size: While cross-validation was performed to address potential overfitting due to sample size, the authors suggest that using data augmentation techniques in future studies could further improve detection accuracy, especially for UWF fundus imaging, which showed a slightly lower AUC than a previous study using a larger dataset.

Future work could involve direct comparisons with expert ophthalmologists, incorporating more diverse imaging modalities, and exploring data augmentation strategies to enhance model performance.

Summary updated

BibTeX
@article{shin2022comparison,
  author = {Younji Shin and Hyunsoo Cho and Yong Un Shin and Mincheol Seong and Jun Won Choi and Won June Lee},
  title = {{Comparison between Deep-Learning-Based Ultra-Wide-Field Fundus Imaging and True-Colour Confocal Scanning for Diagnosing Glaucoma}},
  journal = {Journal of Clinical Medicine},
  year = {2022},
  doi = {10.3390/jcm11113168},
}
Figure