Comparing myelin-sensitive markers MWF, ihMTR, and MTsat in healthy and normal-appearing brain tissue and multiple sclerosis lesions
Lists
Only you see this
Abstract
Measurement of myelin concentration could provide valuable information on the integrity of brain tissue. Several myelin-sensitive magnetic resonance imaging methods have been developed. Here, we compared myelin water fraction (MWF), inhomogeneous magnetization transfer ratio (ihMTR) and magnetization transfer saturation (MTsat) in healthy volunteers and patients with multiple sclerosis (MS). We found highest correlation between MWF and ihMTR but all three measures showed clearly reduced values in MS lesions compared to healthy or normal-appearing white matter. However, the measures varied in differentiating between various WM regions and between peri-lesional tissue and more distant normal-appearing WM.
BibTeX
@inproceedings{berg2023comparing,
author = {Ronja Berg and Viola Pongratz and Markus Lauerer and Thomas Amthor and Guillaume Gilbert and Aurore Menegaux and Claus Zimmer and Christian Sorg and Mariya Doneva and Irene M. Vavasour and Mark Mühlau and Christine Preibisch},
title = {{Comparing myelin-sensitive markers MWF, ihMTR, and MTsat in healthy and normal-appearing brain tissue and multiple sclerosis lesions}},
booktitle = {Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition},
year = {2023},
doi = {10.58530/2022/0890},
}Loading related content...