Comparative Study on Noise Reduction Effect of Fiber Optic Hydrophone Based on LMS and NLMS Algorithm

Zhihua Yu, Yunfei Cai, Daili Mo2020

TL;DR

This paper investigates two adaptive filtering algorithms, LMS and NLMS, for reducing noise in fiber-optic hydrophones. By comparing their performance in terms of total harmonic distortion (THD) and signal-to-noise ratio (SNR), the study finds that the LMS algorithm generally offers superior noise reduction and a smoother signal output, making it a more suitable choice for this application.

What Problem Does This Paper Address?

Fiber-optic hydrophones are crucial for underwater acoustic detection, but their performance is significantly hampered by various noise sources. These include noise from the light source, optical transmission, and environmental factors like vibration and temperature fluctuations. This noise degrades the hydrophone's sensitivity and detection capabilities, limiting its use in large-scale arrays and long-distance applications. While existing noise reduction methods exist, they often rely on traditional signal detection techniques that can be inflexible and struggle with changing environmental conditions. This paper aims to address this by exploring the effectiveness of adaptive filtering, specifically the LMS and NLMS algorithms, in real-time noise cancellation for fiber-optic hydrophones.

Methods

The researchers designed an interferometric fiber-optic hydrophone system using a 3x3 coupler for signal demodulation. To facilitate noise reduction, a reference interferometer with identical parameters to the signal interferometer was introduced. This setup allowed for the generation of a reference signal containing primarily noise, which could then be used by adaptive filters to cancel the noise component in the primary signal.

The core of the study involves comparing two adaptive filtering algorithms:

  • Least Mean Square (LMS) Algorithm: This is a widely used adaptive filtering algorithm known for its simplicity and real-time processing capabilities. The paper implements a version where the step size parameter is variable and automatically adjusted to optimize performance.
  • Normalized Least Mean Square (NLMS) Algorithm: This algorithm is an extension of LMS that normalizes the step size by the energy of the input signal. This normalization aims to improve adaptability, flexibility, and stability, especially in the face of varying input signal energies. The paper uses a fixed step size parameter for NLMS, optimized through preliminary testing.

The performance of these algorithms was evaluated by introducing controlled noise (Gaussian white noise) and valid signals (sine waves) at various frequencies and amplitudes. Key performance metrics included Total Harmonic Distortion (THD) and Signal-to-Noise Ratio (SNR).

Datasets

Not discussed in the paper. The experiments utilized synthetically generated signals (sine waves for valid signals and Gaussian white noise for noise) with controlled parameters (frequency, amplitude, and noise intensity).

Key Insights and Ideas

  • Adaptive Filtering is Effective: Both LMS and NLMS algorithms significantly improve the quality of the demodulated signal from the fiber-optic hydrophone, reducing noise and harmonic distortion.
  • LMS Outperforms NLMS in this Context: Despite NLMS's theoretical advantages in adaptability, the LMS algorithm demonstrated superior performance in reducing THD and improving SNR in this specific hydrophone application.
  • Frequency Dependence: The filtering effectiveness of both algorithms is influenced by signal frequency. While performance is poorer at very low frequencies (below 50 Hz) due to the complexity of filtering harmonics without affecting the signal, it improves significantly for frequencies above 100 Hz.
  • Step Size Parameter is Crucial: The difference in performance between LMS and NLMS is attributed to the step size parameter. LMS's ability to adjust its step size dynamically allows it to better track signal changes and minimize the loss of valid signal information, especially during signal fluctuations. NLMS's step size adjustment, tied to input signal energy, can lead to more abrupt changes and larger errors when the input signal fluctuates significantly.

Key Results

  • Overall Improvement: Both algorithms reduced noise and harmonic distortion, and improved SNR.
  • THD Reduction: The LMS algorithm achieved a better reduction in THD, with an average improvement of about 6 dB over NLMS across different amplitudes.
  • SNR Improvement: LMS also showed a better SNR improvement, approximately 3 dB higher than NLMS, particularly at higher frequencies.
  • Harmonic Reduction: The LMS algorithm provided a smoother signal curve and better reduction of harmonic signals (e.g., triple-frequency harmonics reduced by about 30 dB).
  • Computational Load: The paper suggests LMS has a smaller calculation amount, which is beneficial for real-time applications.

Limitations and Future Work

  • Fixed NLMS Step Size: The study used a fixed, optimized step size for the NLMS algorithm. Further investigation into adaptive step size strategies for NLMS could potentially improve its performance.
  • Specific Noise Type: The experiments primarily used Gaussian white noise. Real-world hydrophone applications might encounter more complex and non-Gaussian noise profiles, which could affect the algorithms' performance.
  • Parameter Optimization: While the paper mentions optimizing parameters, a more exhaustive study on the optimal parameter selection for both algorithms across a wider range of conditions could be beneficial.
  • Future Work: The authors suggest that adaptive filtering schemes are well-suited for noise reduction in interferometric fiber-optic hydrophones and could be integrated into sensor units, arrays, and networks. Further research could explore more advanced adaptive filtering techniques or hybrid approaches.

Summary updated

BibTeX
@misc{yu2020comparative,
  author = {Zhihua Yu and Yunfei Cai and Daili Mo},
  title = {{Comparative Study on Noise Reduction Effect of Fiber Optic Hydrophone Based on LMS and NLMS Algorithm}},
  year = {2020},
  doi = {10.3390/s20010301},
}
Figure