Comparative analysis of the ten Tusscher and Tomek human ventricular cell models at cellular, tissue, and organ levels: Implications for post‐infarct ventricular tachycardia simulation

Ruiqing Dong, Zhenyin Fu, Chuxin Zhang, Yumeng Liu, Yiming Wang, Nan Zhang, Zefeng Wang, Jun Hou, Ling Xia, Yongquan Wu, Shijie Zhou, Dongdong DengPhysiological 2025

TL;DR

This paper systematically compares two popular human ventricular cell models, the ten Tusscher (TT2) and Tomek models, across cellular, tissue, and organ levels to assess their suitability for simulating post-infarct ventricular tachycardia (VT). While both models show distinct behaviors at lower dimensions, their 3D simulations of VT mechanisms are remarkably similar, suggesting both are viable tools for this application.

What Problem Does This Paper Address?

Computational cardiac modeling is crucial for understanding and simulating heart arrhythmias like ventricular tachycardia (VT). The accuracy of these simulations heavily relies on the underlying single-cell models that represent the electrical behavior of heart cells. The ten Tusscher (TT2) model has been a workhorse for simulating arrhythmias due to its balance of efficiency and physiological relevance. However, it's based on older experimental data. The more recent Tomek model aims to improve accuracy by incorporating newer experimental data, particularly for ion channel kinetics and calcium dynamics. Despite the Tomek model's potential advantages, a comprehensive comparison with the widely used TT2 model across different scales (single cell, tissue, and whole organ) was lacking. This study aims to fill that gap, providing guidance on model selection for simulating post-infarct VT.

Methods

The researchers employed a multi-scale simulation approach, evaluating both the TT2 and Tomek models at:

  • 0D (Single Cell): Action potential morphology, ion currents, action potential duration (APD) restitution, and conduction velocity (CV) restitution were analyzed.
  • 1D (Cable): CV restitution was investigated in a linear cable model.
  • 2D (Tissue): Reentrant behaviors and their stability were simulated in a 2D tissue model, including scenarios mimicking scar-related tissue.
  • 3D (Organ): Patient-specific human ventricular models were used to simulate induced reentries, mimicking post-infarct VT.

They also explored the impact of different time steps (5-30 µs) on simulation results and modified ion currents to represent scar-like tissue properties. The simulations were performed using the openCARP software.

Datasets

Not explicitly detailed as "datasets" in the traditional machine learning sense. The models themselves (TT2 and Tomek) are based on existing experimental data and literature. The study utilizes a patient-specific human ventricular anatomical model for the 3D simulations, which is described as being previously detailed in other work.

Key Insights and Ideas

  • Model Differences Emerge Early: The TT2 and Tomek models exhibit distinct electrophysiological properties at the single-cell level, particularly in ion current magnitudes and APD/CV restitution curves. This suggests that for purely cellular-level investigations, the choice of model can significantly impact results.
  • Calcium Dynamics Matter for Reentry: The Tomek model's more detailed representation of intracellular calcium ([Ca²⁺]i) dynamics, while enhancing cellular realism, appears to contribute to more chaotic reentry behavior and wave breaks in 2D tissue simulations. This highlights a potential trade-off between cellular fidelity and tissue-level stability.
  • 3D Behavior Converges: Despite their differences at lower dimensions, the TT2 and Tomek models demonstrate highly comparable 3D reentrant properties, including reentry locations and critical conduction channels, when simulating post-infarct VT. This is a crucial finding for the application of these models.
  • Time Step Sensitivity: The Tomek model shows greater sensitivity to simulation time steps, particularly in 2D simulations, where larger steps can lead to instability or non-clinical "pseudo-reentries." The TT2 model appears more robust in this regard.
  • Computational Cost: The Tomek model, with its more detailed formulations, requires approximately 1.5-1.7 times more computational time than the TT2 model.

Key Results

  • Single Cell: The TT2 model generally showed a higher peak action potential and longer APD, while the Tomek model had a more negative resting potential due to differences in IK1 currents. Significant differences were observed in the magnitudes of various ion currents (e.g., IKs, IK1, INaK).
  • Tissue (2D): The TT2 model produced more stable reentry patterns, whereas the Tomek model exhibited more chaotic reentries and wave breaks, likely due to spatial heterogeneity in [Ca²⁺]i.
  • Organ (3D): Both models successfully reproduced key features of post-infarct VT, including unidirectional block and reentry within scar-like tissue. They generated qualitatively similar reentrant morphologies, with slight differences in cycle lengths and the number of extra-stimuli required to induce VT.
  • Computational Efficiency: Tomek simulations were significantly slower than TT2 simulations.

Limitations and Future Work

  • 3D Simulation Scope: The 3D organ-level simulations were based on a single patient-specific model and a limited number of stimulation sites for the Tomek model. Further validation with a larger cohort and broader clinical data is needed.
  • Mesh Size: For the Tomek model in 2D simulations, the mesh size was sometimes insufficient to prevent boundary-related reentry termination, suggesting larger meshes might be required.
  • Time Step Calibration: The Tomek model's sensitivity to time steps may necessitate smaller steps or additional calibration for large-scale simulations.
  • Hybrid Models: Future work could explore hybrid approaches, such as integrating Tomek's detailed ionic formulations into the TT2 model's more efficient structure.
  • Simplification: Simplifying redundant Ca²⁺-signaling components in the Tomek model could potentially reduce computational burden without compromising fidelity.
  • Clinical Validation: While the models align with realistic protocols, a clinical case-series retrospective study involving both models would be beneficial.

Summary updated

Abstract

Computational modeling is a tool for exploring both normal electrical propagation in healthy hearts and cardiac arrhythmias in patients. While numerous human ventricular cell models exist, the ten Tusscher (TT2) model is one of the most used for simulating ventricular arrhythmia. Recently, the Tomek model has been proposed, offering improved accuracy by better reproducing key depolarization, repolarization, and calcium dynamics in healthy ventricular cardiomyocytes. However, a quantitatively comprehensive comparison of these models at the single-cell, tissue, and organ levels has not been conducted. This study systematically compared the TT2 and Tomek models by evaluating electrophysiological parameters and reentrant properties in 0-dimensional(0D), 1-dimensional(1D), 2-dimensional (2D), and 3-dimensional (3D) simulations. Additionally, the effects of ion currents modifications to simulate ischemic scar-related tissue were analyzed. These results reveal that although the TT2 and Tomek models demonstrate distinct 0D, 1D, and 2D characteristics, their 3D reentrant properties-specifically in terms of reentry locations and critical conduction channels-are highly comparable. Therefore, both models are suitable for simulating post-infarct ventricular tachycardia (VT), as their shared 3D features effectively capture the essential mechanisms underlying this arrhythmia.
BibTeX
@inproceedings{dong2025comparative,
  author = {Ruiqing Dong and Zhenyin Fu and Chuxin Zhang and Yumeng Liu and Yiming Wang and Nan Zhang and Zefeng Wang and Jun Hou and Ling Xia and Yongquan Wu and Shijie Zhou and Dongdong Deng},
  title = {{Comparative analysis of the ten Tusscher and Tomek human ventricular cell models at cellular, tissue, and organ levels: Implications for post‐infarct ventricular tachycardia simulation}},
  booktitle = {Physiological},
  year = {2025},
  doi = {10.14814/phy2.70435},
}
Figure