Clinically viable myocardial CCTA segmentation for measuring vessel-specific myocardial blood flow from dynamic PET/CCTA hybrid fusion

Marina Piccinelli, Navdeep Dahiya, Jonathon A. Nye, Russell D. Folks, C. David Cooke, Daya Manatunga, Doyeon Hwang, Jin Chul Paeng, Sang‐Geon Cho, Joo Myung Lee, Hee‐Seung Bom, Bon‐Kwon Koo, Anthony Yezzi, Ernest GarciaEuropean 2022

TL;DR

Researchers have demonstrated that automated AI-driven segmentation of heart anatomy from CT scans is "good enough" to guide complex blood flow measurements previously requiring hours of manual labor. By reducing processing time from two hours to just a few minutes without sacrificing accuracy, this approach moves vessel-specific myocardial blood flow (MBF) analysis from a research curiosity into a viable clinical tool for diagnosing heart disease.

What Problem Does This Paper Address?

Diagnosing Coronary Artery Disease (CAD) often involves measuring Myocardial Blood Flow (MBF). Traditionally, Positron Emission Tomography (PET) measures this flow across broad anatomical territories. However, this "averaging" can hide localized issues—a small area of restricted flow might be masked by healthy tissue nearby.

To solve this, researchers developed "vessel-specific" MBF (MBFvs), which measures blood flow precisely along the 3D path of individual coronary arteries. The catch? This requires a perfect 3D anatomical map (segmentation) of the heart from a Coronary CT Angiography (CCTA) scan to "fuse" with the PET data. Manually creating these maps takes a trained expert about two hours per patient—a massive bottleneck that prevents the technique from being used in busy hospitals. This paper investigates whether automated AI segmentation can replace the expert without compromising the diagnostic result.

Methods

The study compared three different anatomical modeling approaches across 43 patients:

  1. Manual (M): The gold standard; expert-delineated borders (1.5–2 hours).
  2. Fully Automated (FA): Generated by an AI algorithm in seconds.
  3. Corrected (C): The AI version with brief (2–3 minute) "sanity check" edits by an expert to fix major errors.

The researchers fused these CCTA models with dynamic $^{13}NH_3$ PET data. They then calculated the blood flow at points along the vessels and classified them as "normal" or "abnormal" based on established limits. The primary metric for success was the Dice Coefficient (DC), used here to measure how well the automated flow classifications overlapped with the manual gold standard.

Datasets

The study utilized multimodality datasets from the DEMYSTIFY study, a multisite trial.

  • Participants: 43 patients with varying degrees of CAD.
  • Data Types: $^{13}NH_3$ dynamic PET, CCTA, and invasive Fractional Flow Reserve (FFR) measurements (used as a clinical reference).
  • Sources: Data was contributed by three major medical centers in South Korea (SNUH, SMC, and CNUH).

Key Insights and Ideas

  • The "Resolution Shield": A fascinating "aha moment" in the paper is the realization that pixel-perfect anatomical segmentation isn't strictly necessary. Because PET imaging has a coarser resolution than CT, and because the flow is averaged into small 4mm cubic volumes (ROIs), the final blood flow calculation is remarkably resilient to minor errors in the CT mask borders.
  • The 100% Success Strategy: While the fully automated (FA) masks were fast, they occasionally failed to provide enough coverage for the fusion algorithm to work. However, the "Corrected" (C) model—requiring only a 2-3 minute human intervention—achieved a 100% success rate in extracting flow data.
  • Clinical Viability: The total processing time for the automated/corrected workflow (including fusion and flow calculation) averaged 5–7 minutes. This represents a nearly 20x speedup over the manual process, crossing the threshold into "clinically acceptable" territory.

Key Results

  • High Accuracy: The agreement between the manual and automated/corrected models was excellent, with all Dice Coefficients $\ge$ 0.93.
  • No Statistical Difference: There was no statistically significant difference in the clinical classification (normal vs. abnormal flow) between the manual gold standard and the time-efficient automated/corrected methods.
  • Speed: Manual segmentation took ~120 minutes; automated segmentation took ~15 seconds. Even with manual corrections (2–3 mins) and vessel centerline drawing (2–5 mins), the entire process fits within a standard clinical workflow.

Limitations and Future Work

  • Manual Centerlines: While the heart walls were segmented automatically, the paths of the vessels (centerlines) were still drawn manually. The authors note that automating this step is a logical next goal.
  • Specific AI Weaknesses: The automated tools still struggle with myocardial thickness at the very tip of the heart (the apex) and parts of the septum. Future algorithm iterations will need to focus on these high-curvature areas.
  • Sample Size: While 43 patients provided thousands of data points for flow analysis, larger cohorts will be needed to further validate the tool across more diverse heart morphologies.

Summary updated

Abstract

Fully automated and manually corrected myocardial CCTA segmentation provides anatomical masks in clinically acceptable times for vessel-specific myocardial blood flow measurements using dynamic PET/CCTA image fusion which are not significantly different in flow accuracy and within clinically acceptable processing times compared to fully manually segmented CCTA myocardial masks.
BibTeX
@inproceedings{piccinelli2022clinically,
  author = {Marina Piccinelli and Navdeep Dahiya and Jonathon A. Nye and Russell D. Folks and C. David Cooke and Daya Manatunga and Doyeon Hwang and Jin Chul Paeng and Sang‐Geon Cho and Joo Myung Lee and Hee‐Seung Bom and Bon‐Kwon Koo and Anthony Yezzi and Ernest Garcia},
  title = {{Clinically viable myocardial CCTA segmentation for measuring vessel-specific myocardial blood flow from dynamic PET/CCTA hybrid fusion}},
  booktitle = {European},
  year = {2022},
  doi = {10.1186/s41824-021-00122-1},
}
Figure