Clinical3D-Bench: Evaluating and Improving Spatial Intelligence of Multimodal LLMs in Hospital Environments

Yang Bai, Yingzhi Xia, Ling Lin, Jun Cheng, Lin Fu, Huazhu FuarXiv 2026

TL;DR

Multimodal LLMs can describe a picture of a hospital room, but ask them whether a 1.2-meter transport bed can squeeze past a bedside monitor or what sits on a supine patient's left, and they largely guess. To test and fix this, researchers built Clinical3D-Bench—a photorealistic, physician-vetted benchmark of hospital walkthroughs—and discovered that simply feeding 3D maps into models doesn't work because the models ignore them. Instead, their new GeoJeV framework forces the model to actively compute with 3D scene memory, narrowing the spatial intelligence gap between AI and human doctors.

What Problem Does This Paper Address?

Picture a nurse walking through an intensive care unit. Without breaking stride, they know which bed a lit call-light belongs to, distinguish identical-looking IV poles across bays, and instinctively flip their mental coordinate system to figure out what lies on a patient's left versus their own. They also eyeball whether a crash cart can clear a narrow gap.

If we want AI assistants to safely help in clinical spaces, Multimodal Large Language Models (MLLMs) need these exact 3D spatial reasoning skills from egocentric (first-person) video. Existing spatial benchmarks focus on living rooms or offices and miss clinical nuances like equipment ownership, patient-centered reference frames, and width-constrained navigation. Meanwhile, collecting real hospital video with exact 3D laser scans is a logistical and privacy nightmare.

Figure 1. Clinical3D-Bench. An MLLM answers questions from a hospital walkthrough (middle), with exact answers computed from the 3D scene (right; numbers mark evidence). Three of eight question types illustrate clinical ownership, patient-centered reference frames, and equipment clearance (Fig. 2). Left: selected examples from the 16 room types.

Methods

The authors tackle both the data bottleneck and the modeling bottleneck:

  1. Sim-to-Real Scene Generation: Rather than filming real wards, the authors wrote procedural generators grounded in official hospital building standards (from the UK, Australia, and US VA). They generated 3D layouts in Blender with exact geometric labels, walked a virtual camera through them, and then passed the synthetic renders through image and video generative models (gpt-image-2 and MiniMax-H3) to make them photorealistic. Crucially, they used feature-matching and Perspective-n-Point (PnP) registration to verify the generative video didn't drift off the true 3D camera path, and had ten physicians screen the clips for clinical realism.
  2. Paired Scene States: To catch models relying on lucky guesses or language priors, layouts are generated in multiple "states" where one clinical fact changes—like moving a lit bed-head light from Bed 01 to Bed 02—testing if the model updates its answer accordingly.
  3. GeoJeV (Computing with 3D): Standard ways of making MLLMs "3D-aware" involve feeding Bird's-Eye-View (BEV) maps or geometry tokens into the model's input. After finding models ignore these inputs, the authors built GeoJeV. GeoJeV reconstructs an explicit 3D scene memory from a video clip and equips a fine-tuned MLLM (VideoJev-4B) with lightweight linear heads. Based on the model's internal question state, these heads select specific 3D primitive operations (object-track queries, free-space analysis, or learned BEV map reads) and their arguments. The resulting geometric evidence is added directly to the MLLM's answer-option scores—no messy program synthesis or second LLM required.

Datasets

The paper introduces two disjoint datasets built from 16 hospital room types (ICUs, operating rooms, X-ray suites, corridors, etc.):

  • Clinical3D-Bench (Evaluation): 3,368 multiple-choice questions across 569 ten-second photorealistic clips (373 layouts). It covers eight question types grouped into Spatial Memory (counting, re-identifying equipment), Ownership & Relations (light ownership, device labels), Frames of Reference (patient's left/right), and Metric Navigation (turn directions, shortest routes, width passability).
  • Clinical3D-45K (Training): 44,750 questions across 5,199 rendered clips from 518 separate layouts, complete with metric depth, poses, and 3D bounding boxes.
Examples of spatial memory and ownership/relation questions in Clinical3D-Bench, including paired states.

Key Insights and Ideas

  • Zero-shot MLLMs fail at perspective-taking: On two-way "patient's left or right?" questions where random chance is 50%, 27 out of 32 open-source models scored below 40%. They systematically confuse their own camera view with the patient's perspective.
  • Models stubbornly repeat themselves: On paired scene states where the ground-truth answer changes, zero-shot models keep giving the exact same answer far more often than their baseline preferences predict, proving they aren't actually looking at the changing visual evidence.
  • Giving 3D maps as input is an illusion: When the authors fine-tuned an MLLM and fed it explicit BEV map tokens—even ground-truth maps—overall accuracy barely budged. The smoking gun? Swapping a video's 3D map with a completely different room's map caused almost zero drop in accuracy. The MLLM simply learned to ignore the 3D tokens. Forcing explicit 3D computation via GeoJeV fixed this: swapping GeoJeV's scene memory drops accuracy by over 5 points, proving it genuinely uses the geometry.

Key Results

  • Zero-shot vs. Humans: Across 35 evaluated MLLMs, the best open models (InternVL3-14B / 3.5-14B) hit 45.7% macro accuracy—barely beating a blind, test-fitted answer prior (40.8%). Top proprietary models (Gemini 3.6 Flash, GPT-5.5, Claude Sonnet 5.5) reached 51.3%–53.6%, whereas five human physicians scored 79.0% on a 400-question subset (and 94.0% on patient perspective).
  • Fine-tuning & GeoJeV: Fine-tuning VideoJev-4B on Clinical3D-45K vaulted its accuracy from 45.5% to 73.9% (and lifted patient-frame accuracy from 17.0% to 93.7%). Adding GeoJeV pushed macro accuracy to 75.7%—the highest of all tested models—with notable gains in counting, re-identification, direction, and passability (69.8%).

Limitations and Future Work

  • Route planning remains a wall: Even after domain fine-tuning and adding GeoJeV, multi-turn walking route accuracy only crept up from 58.3% to 59.5% (incidentally, Route and Passability were also the hardest tasks for human doctors from video alone, at 60.0% and 64.0%).
  • Unverified small objects in transfer: The PnP pose gate verifies that the photorealistic video transfer preserves the camera path, and doctors screened out visual artifacts, but it does not mathematically guarantee every tiny piece of visual evidence survived the style transfer intact.
  • Benchmark refinement bias: Because Qwen3-VL-8B and -32B were used during creation to filter out overly easy question formulations, their evaluated scores on the benchmark may be biased downward compared to other models. ( Note: pages beyond page 6 were not included in the provided document, so concluding discussions of future work are not available.)

Summary updated

Abstract

Spatial reasoning in hospitals requires tracking look-alike equipment, interpreting patient-relative directions, and judging passage widths, yet existing benchmarks provide limited coverage of these abilities. We introduce Clinical3D-Bench, a simulated benchmark with 3,368 questions of eight types on egocentric walkthroughs of 373 hospital-room layouts. Layouts follow hospital design guidelines, answers are computed from the 3D scenes, and paired scene states test whether models change their answers when relevant evidence changes. Videos are photorealistic, and ten physicians screened the layouts. Among 35 multimodal large language models (MLLMs), the best open and proprietary models reach 45.7% and 53.6% macro accuracy, against 40.8% for an answer prior and 79.0% for physicians on a subset, and 27 of 32 open models score below 40% on two-way patient-relative directions. Fine-tuning on Clinical3D-45K, our 44,750-question training set, lifts two MLLMs 16-20 points above the best proprietary model. 3D maps given to the fine-tuned MLLM as input go largely unused: replacing them with another video's, even when they are ground truth, barely changes its accuracy. The proposed GeoJeV instead lets the MLLM compute with 3D: it reconstructs a scene memory from each video, selects 3D operations and their arguments from the MLLM's question state, and adds their evidence to its option scores. It achieves the highest accuracy of all evaluated models, narrowing the gap to physicians.
BibTeX
@misc{bai2026clinical,
  author = {Yang Bai and Yingzhi Xia and Ling Lin and Jun Cheng and Lin Fu and Huazhu Fu},
  title = {{Clinical3D-Bench: Evaluating and Improving Spatial Intelligence of Multimodal LLMs in Hospital Environments}},
  year = {2026},
  eprint = {2611.32094},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.32094},
}
Figure