Clinical performance of long-term temporary fixed dental prostheses fabricated from CAD/CAM resin-based composite

Florian Dold, Karolina Müller, Martin V. Butz, Sebastian HahnelClinical 2025 · DOI

TL;DR

This study investigates the clinical performance of long-term temporary fixed dental prostheses (LTFDPs) made from CAD/CAM resin-based composites. The findings suggest that while these materials offer comparable failure rates to older technologies, adhesive luting may significantly reduce the risk of decementation, a common complication.

What Problem Does This Paper Address?

In fixed prosthetic dentistry, temporary restorations are crucial for protecting prepared teeth, guiding gingival healing, and evaluating functional and aesthetic parameters before definitive treatment. For patients requiring extended monitoring or periodontal therapy, long-term temporary fixed dental prostheses (LTFDPs) are employed. Traditionally, these were fabricated using direct techniques with resin-based composites, which could lead to issues like voids, discoloration, and poor marginal adaptation due to suboptimal polymerization. CAD/CAM technology offers a potential solution by enabling the fabrication of prostheses from industrially optimized resin blocks. However, clinical data on the performance of LTFDPs made from these newer CAD/CAM resin-based composites, particularly those with low filler content, has been limited. This paper aims to fill that gap by evaluating the clinical performance, failure rates, and complications of such LTFDPs.

Methods

This study employed a retrospective design, analyzing data from 46 patients who received 73 LTFDPs fabricated from a specific CAD/CAM resin-based composite (Structur CAD, VOCO GmbH) with 27% filler content. The LTFDPs included partial-coverage crowns, crowns, and fixed dental prostheses. Data was collected from the institutional electronic database and through manual screening of clinical datasets. Statistical analyses included mixed-effects Cox regression to assess time-to-failure based on restoration type and generalized estimating equation (GEE) models with binary regression to evaluate decementation probability based on the luting agent.

Datasets

The study utilized retrospective clinical data from 44 patients (with 71 LTFDPs) treated at the Department of Prosthetic Dentistry at Regensburg University Medical Center between April 2022 and January 2024. The datasets included information on partial-coverage crowns (N=12), crowns (N=31), and fixed dental prostheses (N=28). The data was collected from institutional records. No new benchmarks were introduced; the study evaluated existing patient data.

Key Insights and Ideas

  • CAD/CAM resin composites show promise for LTFDPs: The study demonstrates that LTFDPs fabricated from CAD/CAM resin-based composites exhibit clinically acceptable failure rates, comparable to those reported for older materials like polymethyl methacrylate (PMMA).
  • Decementation is a key concern, but luting matters: Decementation emerged as the most frequent complication. Crucially, the study found a significantly higher probability of decementation when restorations were luted temporarily or self-adhesively compared to adhesive luting.
  • Restoration type doesn't significantly impact failure: Contrary to potential assumptions, the type of restoration (partial-coverage crown, crown, or fixed dental prosthesis) did not significantly influence the failure rates.
  • Adhesive luting is recommended for longevity: The findings strongly suggest that for LTFDPs intended for longer service periods (beyond 30 days), adhesive luting with resin-based composites is preferable to temporary or self-adhesive cements to minimize decementation.

Key Results

  • A total of 71 LTFDPs from 44 patients were analyzed, with a median observation time of 362.0 days.
  • Failure due to fracture occurred in 14.1% of LTFDPs.
  • Decementation was the most frequent complication, observed in 18.1% of all LTFDPs.
  • There was no statistically significant difference in failure rates between partial-coverage crowns, crowns, and fixed dental prostheses.
  • The probability of decementation was significantly higher in restorations luted temporarily (OR=20.50) and self-adhesively (OR=12.30) compared to those luted adhesively.
  • Secondary caries was a rare complication, occurring in only one case (1.4%).

Limitations and Future Work

The authors acknowledge several limitations:

  • Periodontal status not standardized: The periodontal status of abutment teeth was not consistently documented, preventing its inclusion as a confounding factor in the analysis. This could be particularly relevant as compromised abutment teeth might be more susceptible to stress.
  • Operator expertise variation: The study included treatments performed by both experienced dentists and supervised undergraduate students, potentially introducing variability.
  • Limited observation time: While the median observation time was over a year, longer-term follow-up would provide more comprehensive data.
  • Retrospective design and potential bias: The retrospective nature of the study and the inclusion of multiple restorations per patient could introduce bias, although statistical methods were employed to address this.
  • Occlusal adjustment impact: The potential for occlusal adjustments during try-in to affect the minimal thickness threshold of the restorations was not controlled for.

Future work should focus on:

  • Further investigating luting protocols for partial-coverage crowns, particularly those fabricated from CAD/CAM resin-based composites, given the high number of decementations observed in this subgroup.
  • Conducting prospective studies with standardized documentation of periodontal status and operator expertise to provide more robust evidence.
  • Exploring the debonding pattern of LTFDPs to gain deeper insights into the interaction between the composite material and the luting agent.

Summary updated

Abstract

LTFDPs fabricated from resin-based composite have similar failure rates as reported for polymethyl methacrylate based LTFPDs. Adhesive luting might help to reduce the probability of decementation.
BibTeX
@inproceedings{dold2025clinical,
  author = {Florian Dold and Karolina Müller and Martin V. Butz and Sebastian Hahnel},
  title = {{Clinical performance of long-term temporary fixed dental prostheses fabricated from CAD/CAM resin-based composite}},
  booktitle = {Clinical},
  year = {2025},
  doi = {10.1007/s00784-025-06259-8},
}
Figure