Chronic wound assessment and infection detection method

Jui-Tse Hsu, Yung-Wei Chen, Te-Wei Ho, Hao-Chih Tai, Jin-Ming Wu, Hsin-Yun Sun, Chi-Sheng Hung, Yi-Chong Zeng, Sy-Yen Kuo, Feipei LaiBMC Medical Informatics Decis. Mak 2019 · DOI · OpenReview

Introduction

Monitoring chronic wounds, such as diabetic ulcers or post-surgical incisions, is a critical yet manual and subjective process that places a significant burden on the healthcare system. Existing automated tools often require specialized hardware like 3D scanners or infrared cameras, which are impractical for routine remote monitoring. This paper, published in BMC Medical Informatics and Decision Making, proposes a software-based framework for automated wound assessment using standard smartphone imagery. By integrating computer vision with machine learning, the researchers aim to provide a reliable path for remote clinical monitoring.

Methodology

The proposed system consists of two primary modules: robust segmentation and infection assessment.

Robust Segmentation

The first challenge in automated assessment is isolating the wound from healthy skin and background noise. The authors developed a multi-step segmentation pipeline:

  • Edge Enforcement: Canny edge detection is enhanced with a custom "mending" step using a 3x3 grid to connect broken edges.
  • Wrinkle Suppression: To prevent standard edge detectors from mistaking skin wrinkles for wound boundaries, the team implemented an "Optimized Threshold" algorithm. This iterative process adjusts sensitivity based on line density and slope, filtering out fine skin textures while preserving the wound's primary structure.
  • Color Filtering: Non-skin pixels are excluded using the HSV (Hue, Saturation, Value) color space.
Original wound image and the edge detected result after applying the CED

Infection Assessment

Following segmentation, the system evaluates the wound for clinical symptoms including swelling, granulation, infection, and tissue necrosis.

  • Feature Extraction: Rather than using generic SIFT features, the authors utilized morphological cross-shaped features. This approach leverages the geometric property that surgical sutures are typically perpendicular to the main incision.
  • Automated Clustering: Hierarchical Clustering (HCM) groups these features into Regions of Interest (ROIs). The number of clusters is automatically determined using a unimodal Rosin threshold applied to the iVar metric (inverse of silhouette score variance).
  • Classification: A Support Vector Machine (SVM) with a third-degree polynomial kernel classifies these ROIs to provide a diagnostic assessment.

Results and Performance

The study utilized a dataset of 293 wound images from the National Taiwan University Hospital (NTUH), with 159 used for training and 134 for testing. Ground truth was established by three professional physicians.

The system demonstrated strong performance across several metrics:

  • Segmentation: Achieved a 76.44% true positive rate and an overall accuracy of 89.04%.
  • Anomaly Detection: Distinguished between normal and abnormal (infected/necrotic) wounds with 87.31% accuracy.
  • Symptom Classification: Identified specific clinical symptoms with 83.58% accuracy.
  • Efficiency: Optimization of the SVM kernel reduced hyperparameter tuning time from 1,200 minutes to just 32 minutes.

Discussion and Future Directions

A key insight from this work is the superiority of domain-specific feature engineering over general-purpose computer vision techniques. By targeting the specific geometry of sutures and treating skin wrinkles as a complex noise source, the system achieves high reliability in "wild" photographic conditions.

However, limitations remain. Future work will address color calibration issues across different smartphone sensors using physical calibration cards. Additionally, incorporating texture analysis (e.g., entropy or skewness) may improve the detection of early-stage necrosis. As the dataset expands, the authors anticipate transitioning to Deep Convolutional Neural Networks (CNNs) to further enhance diagnostic precision while maintaining a mobile-first approach.

Summary updated

Abstract

Background Numerous patients suffer from chronic wounds and wound infections nowadays. Until now, the care for wounds after surgery still remain a tedious and challenging work for the medical personnel and patients. As a result, with the help of the hand-held mobile devices, there is high demand for the development of a series of algorithms and related methods for wound infection early detection and wound self monitoring. Methods This research proposed an automated way to perform (1) wound image segmentation and (2) wound infection assessment after surgical operations. The first part describes an edge-based self-adaptive threshold detection image segmentation method to exclude nonwounded areas from the original images. The second part describes a wound infection assessment method based on machine learning approach. In this method, the extraction of feature points from the suture area and an optimal clustering method based on unimodal Rosin threshold algorithm that divides feature points into clusters are introduced. These clusters are then merged into several regions of interest (ROIs), each of which is regarded as a suture site. Notably, a support vector machine (SVM) can automatically interpret infections on these detected suture site. Results For (1) wound image segmentation, boundary-based evaluation were applied on 100 images with gold standard set up by three physicians. Overall, it achieves 76.44% true positive rate and 89.04% accuracy value. For (2) wound infection assessment, the results from a retrospective study using confirmed wound pictures from three physicians for the following four symptoms are presented: (1) Swelling, (2) Granulation, (3) Infection, and (4) Tissue Necrosis. Through cross-validation of 134 wound images, for anomaly detection, our classifiers achieved 87.31% accuracy value; for symptom assessment, our classifiers achieved 83.58% accuracy value. Conclusions This augmentation mechanism has been demonstrated reliable enough to reduce the need for face-to-face diagnoses. To facilitate the use of this method and analytical framework, an automatic wound interpretation app and an accompanying website were developed. Trial registration 201505164RIND , 201803108RSB .
BibTeX
@article{hsu2019chronic,
  author = {Jui-Tse Hsu and Yung-Wei Chen and Te-Wei Ho and Hao-Chih Tai and Jin-Ming Wu and Hsin-Yun Sun and Chi-Sheng Hung and Yi-Chong Zeng and Sy-Yen Kuo and Feipei Lai},
  title = {{Chronic wound assessment and infection detection method}},
  journal = {BMC Medical Informatics Decis. Mak.},
  year = {2019},
  doi = {10.1186/s12911-019-0813-0},
}
Figure