CHIME: CMOS-hosted in-vivo microelectrodes for massively scalable neuronal recordings

Mihály Köllő, Romeo Rácz, Mina-Elraheb Hanna, Abdulmalik Obaid, Matthew R. Angle, William Wray, Yifan Kong, Andreas Hierlemann, Jan Müller, Nicholas A. Melosh, Andreas T. SchaeferbioRxiv 2019 · DOI

TL;DR

This paper introduces CHIME (CMOS-Hosted In-vivo MicroElectrode) recordings, a novel system that combines flexible, glass-ensheathed microwire bundles with scalable CMOS amplifier arrays. This approach overcomes the limitations of current technologies in recording from large populations of neurons in the brain, enabling high-density, high-temporal resolution recordings with minimal tissue damage.

What Problem Does This Paper Address?

Understanding the mammalian brain, with its billions of neurons operating at millisecond timescales, requires recording from a vast number of neurons simultaneously. Current electrophysiological recording techniques struggle to scale to this level. Existing methods often capture only a tiny fraction of neural activity, and their two-dimensional nature clashes with the brain's three-dimensional structure. This limits neurophysiological research and the development of neural prosthetics. Specifically, silicon probes have limitations in space coverage, inflexible site arrangement, and can cause significant tissue damage, hindering the ability to record from large, distributed neuronal ensembles.

Methods

The core innovation of CHIME lies in its hybrid approach:

  • Microwire Fabrication: Kilometre-long, glass-insulated microwires with conductive metal cores (down to <1 µm) are fabricated using a modified Taylor-Ulitovsky method. These wires are designed to be small, sharp, and smooth to minimize tissue damage. Electrochemical modification of the tips is used to achieve ultra-low access impedance.
  • Bundle Formation: Microwires are bundled (up to 1000 wires per bundle) and embedded in a polymer. The chip-end is polished flat, and the exposed metal cores are enhanced with gold electrodeposition for better electrical contact. The tissue-end is sharpened and prepared to minimize tissue damage. Techniques like splaying or sacrificial spacers are used to control inter-wire spacing.
  • CMOS Integration: The microwire bundles are directly bonded to high-density CMOS amplifier arrays. Two types of CMOS systems were explored:
  • MEA chips: High-density, switch-matrix based chips (like MEA1k) that allow selective recording from connected pixels.
  • IR Camera ROICs: Repurposed CMOS infrared camera readout integrated circuits (like Xenics Cheetah 640CL) offering a massive number of pixels (over 300,000) for potential high-density recording.
  • Direct Contacting: A scalable method for connecting the microwire bundle to the CMOS chip was developed, involving electrochemical gold bumping on the microwire ends and pressing them onto the CMOS pixels.

Datasets

Not discussed in the paper. The paper focuses on a novel hardware system and its performance in vivo.

Key Insights and Ideas

  • Bridging 2D and 3D: The CHIME approach ingeniously "lifts" the 2D CMOS architecture into the 3D space of the brain using microwire bundles, overcoming a fundamental mismatch.
  • Minimally Invasive by Design: The ultrathin microwires (<1 µm core diameter) and smooth, sharp tips significantly reduce blood-brain barrier damage upon insertion, a critical factor for chronic in vivo recordings.
  • Scalability through Modularity: The system leverages the rapid scaling of silicon microfabrication (CMOS) and the inherent scalability of wire bundling, promising a path to recording from millions of neurons.
  • Low Noise, High Signal: The combination of ultrathin conductive cores, low stray capacitance, and optimized electrochemical tip modification leads to high signal-to-noise ratios, crucial for detecting faint neuronal signals.
  • Flexibility in Application: The modular design allows for custom arrangement of recording sites, enabling researchers to tailor the system to specific brain regions and research questions.

Key Results

  • Low Noise Floor: Achieved RMS noise levels as low as 6.5 ± 2.6 µV in connected MEA1k pixels after correlated noise subtraction.
  • High Signal-to-Noise Ratio (SNR): Demonstrated SNRs up to 25 for single unit spikes (500 µV amplitude) recorded in mouse brain.
  • Minimal Tissue Damage: Histology showed minimal blood-brain barrier damage upon insertion of 20 µm diameter microwire bundles, significantly less than standard silicone probes.
  • Stable Single Unit Recordings: Successfully recorded stable single unit activity in the mouse olfactory bulb using both MEA and IR camera CMOS systems.
  • High Channel Density Potential: The system is designed to scale to hundreds of thousands or millions of channels by leveraging CMOS technology.

Limitations and Future Work

  • Head-Fixed Experiments: The current system is designed for head-fixed experiments, limiting its application in freely moving animals.
  • Data Handling and Analysis: As with any large-scale recording system, data handling and analysis remain significant challenges.
  • Buckling Force: For even smaller wires, the critical buckling force for insertion without support becomes a limiting factor. The authors suggest temporary coating agents or alternative fabrication methods for smaller probes.
  • Tethering: While the low stray capacitance allows for long wire bundles, the current system is tethered. The authors envision future work to abandon tethering by moving active electronics outside the skull for wireless transmission, especially for larger mammals.
  • Alternative Materials: The paper mentions that while glass wires have advantages, other materials like carbon fibers or plastic wires could be explored, each with their own trade-offs in terms of scalability, flexibility, and electrical properties.
  • Tip Impedance: For smaller probes, tip impedance could become too high, impeding signal strength. Future work may involve novel materials to increase surface area and improve coupling.

Summary updated

Abstract

Summary Mammalian brains consist of 10s of millions to 100s of billions of neurons operating at millisecond time scales, of which current recording techniques only capture a tiny fraction. Recording techniques capable of sampling neural activity at such temporal resolution have been difficult to scale: The most intensively studied mammalian neuronal networks, such as the neocortex, show layered architecture, where the optimal recording technology samples densely over large areas. However, the need for application-specific designs as well as the mismatch between the threedimensional architecture of the brain and largely two-dimensional microfabrication techniques profoundly limits both neurophysiological research and neural prosthetics. Here, we propose a novel strategy for scalable neuronal recording by combining bundles of glass-ensheathed microwires with large-scale amplifier arrays derived from commercial CMOS of in-vitro MEA systems or high-speed infrared cameras. High signal-to-noise ratio (&lt;20 μV RMS noise floor, SNR up to 25) is achieved due to the high conductivity of core metals in glass-ensheathed microwires allowing for ultrathin metal cores (down to &lt;1 μm) and negligible stray capacitance. Multi-step electrochemical modification of the tip enables ultra-low access impedance with minimal geometric area and largely independent of core diameter. We show that microwire size can be reduced to virtually eliminate damage to the blood-brain-barrier upon insertion and demonstrate that microwire arrays can stably record single unit activity. Combining microwire bundles and CMOS arrays allows for a highly scalable neuronal recording approach, linking the progress of electrical neuronal recording to the rapid scaling of silicon microfabrication. The modular design of the system allows for custom arrangement of recording sites. Our approach of employing bundles of minimally invasive, highly insulated and functionalized microwires to lift a 2-dimensional CMOS architecture into the 3rd dimension can be translated to other CMOS arrays such as electrical stimulation devices.
BibTeX
@misc{kollo2019chime,
  author = {Mihály Köllő and Romeo Rácz and Mina-Elraheb Hanna and Abdulmalik Obaid and Matthew R. Angle and William Wray and Yifan Kong and Andreas Hierlemann and Jan Müller and Nicholas A. Melosh and Andreas T. Schaefer},
  title = {{CHIME: CMOS-hosted in-vivo microelectrodes for massively scalable neuronal recordings}},
  year = {2019},
  doi = {10.1101/570069},
  howpublished = {bioRxiv},
}
Figure