Chemical fingerprinting and quantitative analysis of a Panax notoginseng preparation using HPLC-UV and HPLC-MS

Hong Yao, Peiying Shi, Qing Shao, Xiaohui FanChinese 2011 · DOI

TL;DR

This paper presents a robust method for the quality control of Xuesaitong (XST) injection, a traditional Chinese medicine derived from Panax notoginseng. By employing a combination of HPLC-UV and HPLC-MS, the researchers developed a chemical fingerprinting technique that can identify and quantify the key active saponin components, ensuring product consistency and efficacy.

What Problem Does This Paper Address?

Panax notoginseng (Sanqi) is a widely used herb in traditional Chinese medicine, particularly in the form of Xuesaitong (XST) injection, for treating cardiovascular and cerebrovascular diseases. The efficacy of XST injection relies on its total saponin content, which includes a complex mixture of ginsenosides and notoginsenosides. However, existing quality control methods often struggle to comprehensively analyze these saponins due to the sheer number of compounds, limited availability of reference standards, and challenges in achieving adequate chromatographic separation. This lack of a thorough evaluation method poses a risk to the safety, efficacy, and stability of the XST injection. The study aims to address this by developing a more comprehensive and systematic quality evaluation method.

Methods

The researchers employed a two-pronged analytical approach:

  • HPLC-UV Fingerprinting: High-performance liquid chromatography with ultraviolet detection (HPLC-UV) was used to generate "chemical fingerprints" of the XST injection. This involves separating the various saponin components and creating a unique chromatographic profile for each sample. The method was optimized for column type, mobile phase composition, detection wavelength (203 nm, chosen due to low UV absorption of most saponins), and column temperature (30°C). A gradient elution program was developed to achieve good separation of the complex mixture within a reasonable timeframe (85 minutes total run time).
  • HPLC-PDA/ESI-MS Identification: To identify the characteristic peaks observed in the HPLC-UV fingerprints, a more advanced technique, HPLC with photo diode array detection and electrospray ionization tandem mass spectrometry (HPLC-PDA/ESI-MS), was utilized. This allowed for the determination of the molecular weight of each separated component, aiding in their identification by comparing with known saponin reference standards and literature data.

For quantitative analysis, ten specific saponin reference standards were available. These were used to create calibration curves for accurate quantification. For the remaining 17 saponins that lacked reference standards, a semi-quantification approach was employed, leveraging the observed correlation between molecular weights and chromatographic behavior of similar compounds.

Datasets

The study utilized ten batches of XST injection samples obtained from various Chinese pharmaceutical companies. Additionally, ten specific saponin reference compounds were used for identification and quantification. No new benchmark datasets were introduced; rather, existing reference standards and literature data were leveraged.

Key Insights and Ideas

  • The Power of Fingerprinting for Complex Mixtures: The study demonstrates the effectiveness of chemical fingerprinting as a holistic approach to quality control for complex herbal medicines like XST injection. Instead of focusing on a few isolated markers, it captures the overall chemical profile, providing a more comprehensive assessment.
  • HPLC-UV as a Workhorse for Initial Screening: The optimized HPLC-UV method proved capable of separating a significant number of saponin peaks (27 identified as "common saponins") with good resolution, making it a practical tool for routine quality control.
  • HPLC-MS for Definitive Identification: The combination with HPLC-PDA/ESI-MS was crucial for confidently identifying the characteristic peaks, bridging the gap between observed chromatograms and known chemical entities.
  • Semi-Quantification as a Practical Solution: The paper highlights a pragmatic approach to dealing with the lack of reference standards for all active compounds. By using established correlations, they could still estimate the contribution of these less characterized saponins to the overall composition.
  • Low UV Absorption of Saponins: The finding that most saponins exhibit low UV absorption above 203 nm is important for method development, guiding the selection of the optimal detection wavelength.

Key Results

  • A representative chemical fingerprint for XST injection was established, revealing 27 "common saponins" present across ten analyzed batches.
  • Using HPLC-PDA/ESI-MS and reference standards, 10 specific saponins were identified and quantitatively determined.
  • The remaining 17 saponins were semi-quantified using substitutive standard references.
  • The developed method allowed for the examination of 81.81% to 95.71% of the total saponin components in the XST injection.
  • Among the quantified saponins, ginsenoside Rb₁ was found to be the most abundant (26.17%-29.60%), followed by ginsenoside Rg₁ (20.50%-25.43%), Rd (6.82%-8.10%), notoginsenoside R₁ (5.29%-6.89%), and ginsenoside Re (2.91%-4.92%).

Limitations and Future Work

  • Limited Reference Standards: The primary limitation acknowledged is the difficulty in obtaining reference standards for all 27 identified saponins. While semi-quantification was employed, it inherently carries more uncertainty than direct quantification.
  • Method Validation: While the paper mentions validation in the additional materials, a detailed discussion of the validation parameters (e.g., linearity, accuracy, precision, robustness) for the simultaneous determination of all 27 saponins would strengthen the findings.
  • Future Work: The authors suggest that this fingerprinting and quantitative analysis method could be applicable to other Panax notoginseng products and potentially other herbal medicines, indicating a broader potential for their developed approach. Further research could focus on obtaining more reference standards to improve the accuracy of the semi-quantified saponins.

Summary updated

Abstract

Chemical fingerprinting and quantitative analysis identified most of the common saponins for the quality control of P. notoginseng products such as the XST injection.
BibTeX
@inproceedings{yao2011chemical,
  author = {Hong Yao and Peiying Shi and Qing Shao and Xiaohui Fan},
  title = {{Chemical fingerprinting and quantitative analysis of a Panax notoginseng preparation using HPLC-UV and HPLC-MS}},
  booktitle = {Chinese},
  year = {2011},
  doi = {10.1186/1749-8546-6-9},
}
Figure