Abstract
The oxidation resistance is one of the most important properties of refractory materials. China national standard GB/T 32329-2015, which title is "Test method for oxidation resistance of oxynitride materials-non-isothermal oxidation", provide a standard characterizing method for oxidation resistance. In our work we validate this standard and test the oxidation resistance of six SiAlON samples using this method. The oxidation resistance property of oxynitride materials could be well described with these indicators: the oxidation weight gain per unit area, the initial oxidation temperatures and the maximum oxidation rate temperatures. From the experimental results we conclude that this standard is scientific and feasible.
Introduction
SiAlON (Silicon Aluminum Oxynitride) ceramics are high-performance refractory materials valued for their hardness, low density, and resistance to corrosion by molten metals. However, their primary weakness is oxidation at high temperatures, which can lead to structural degradation. To ensure the safe application of these materials in industrial furnaces, precise characterization of their thermal limits is essential. This paper validates the China national standard GB/T 32329-2015, a non-isothermal testing method designed to provide a reproducible framework for determining the oxidation resistance of oxynitride ceramics.
Methods
The researchers employed non-isothermal Thermogravimetric Analysis (TGA) using a TGA-16 analyzer. Six SiAlON samples were synthesized and cut into rectangular blocks (approx. 25x15x15 mm) to ensure consistent surface-area-to-volume ratios. The core of the method involves ramping the temperature in air (1 L/min flow rate) through specific stages:
- Room Temp to 800°C: 10°C/min
- 800°C to 1100°C: 8°C/min
- 1100°C to 1500°C: 4°C/min
- Isothermal Dwell: 120 minutes at 1500°C.
To interpret the resulting data, the standard utilizes two key mathematical markers derived from the weight gain curve ($R_m$) and its first derivative ($dR_m/dT$):
- $T_2$ (Maximum Oxidation Rate Temperature): The peak of the $dR_m/dT$ curve, representing the point of fastest oxidation.
- $T_1$ (Initial Oxidation Temperature): Defined by the intersection of the baseline and a tangent line drawn at $T_2$.
Key Results
The experimental validation yielded consistent performance metrics across the synthesized samples, proving the standard's robustness. The average values identified were:
- Initial Oxidation Temperature ($T_1$): ~1036°C, suggesting a safe operating limit near 1000°C.
- Maximum Oxidation Rate Temperature ($T_2$): ~1171°C, identifying the critical "danger zone" for material degradation.
- Oxidation Weight Gain ($G$): 0.25 mg/mm² after the full cycle.
The tangent method for determining $T_1$ provides a mathematically consistent way to define the onset of oxidation, effectively removing human bias from the analysis.
Discussion and Limitations
While the GB/T 32329-2015 standard proved highly operable and scientific, several factors warrant further investigation:
- Material Scope: The study focused on a specific SiAlON type. Testing a broader range of oxynitrides, such as Silicon Nitride, would further validate the standard's universality.
- Atmospheric Variables: Industrial environments often contain moisture or combustion gases that differ from the controlled air used in TGA, potentially altering oxidation profiles.
- Long-term Correlation: Future work should correlate these short-term non-isothermal results with long-term isothermal "soak" tests to confirm if $T_1$ accurately predicts multi-year lifespans in operational furnaces.
Summary updated