Characteristics for Machine Learning Detection of Large Vessel Occlusion on Computed Tomography Angiography

Lingam Amara Swapna, Lucas W. Remedios, Samuel W. Remedios, Bennett A. Landman, L. Taylor Davis, Stephen W. ClarkmedRxiv 2023 · DOI

Abstract

Automated detection of large vessel occlusion (LVO) using machine learning on computed tomography angiography (CTA) is a promising tool for stroke triage. However, the influence of varied patient and image characteristics on model performance remains under-examined. This study evaluates a convolutional neural network (CNN) trained to identify LVOs in the internal carotid artery (ICA), M1, or M2 segments. Using a retrospective cohort of 300 patients, the model achieved an area under the receiver operating characteristic curve (ROC-AUC) of 0.920 in cross-validation and 0.852 in external validation. Error analysis revealed that lower window settings (image contrast) were significantly associated with misclassifications. Additionally, smoking history was prevalent in all false negative cases, and many false positives represented clinically significant distal occlusions. These findings highlight the importance of image quality and the potential for AI to detect vascular pathology beyond its primary training targets.

Introduction

In the treatment of acute ischemic stroke caused by a Large Vessel Occlusion (LVO), time is the most critical factor. Rapid identification of blockages in major brain arteries allows for timely intervention, such as mechanical thrombectomy. While automated machine learning tools have been developed to assist in triage by flagging occlusions on CTA scans, many operate as "black boxes." There is a lack of clarity regarding how clinical variables—such as patient demographics, risk factors, or technical image settings—impact the reliability of these algorithms. This study aims to perform a deep-dive error analysis of a CNN-based LVO detection tool to identify the specific characteristics that drive diagnostic success or failure.

Methods

Data Preparation and Preprocessing

The study utilized a retrospective cohort of 677 stroke-alerted patients from a comprehensive stroke center, narrowed to a balanced dataset of 300 patients (150 with LVO; 150 without). To optimize the data for a CNN, 3D CTA scans were converted into 2D Maximum Intensity Projection (MIP) images. This process preserves the high-intensity signal of blood vessels while reducing computational complexity. A critical step in the pipeline involved manual "windowing"—adjusting the brightness and contrast settings to ensure optimal vessel visibility, as the model struggled to learn from unadjusted raw data.

Model Development

Five different architectures were evaluated: PhiNet, EfficientNet-B0, DenseNet-121, ResNet-50, and an Inception V1-based module. The Inception-based network was selected as the top performer for the binary classification of LVO presence. Performance was validated using 10-fold cross-validation and a separate external validation set.

Statistical Analysis

To understand the drivers of error, the researchers compared "True Positive" (TP) cases against "False Negative" (FN) cases and "True Negative" (TN) against "False Positive" (FP) across a wide array of variables, including demographics, medical history (e.g., smoking, hypertension), and technical image parameters.

Results

The Inception-based model demonstrated high diagnostic accuracy and robustness across various occlusion locations:

  • Performance Metrics: The model achieved a cross-validation ROC-AUC of 0.920 (Sensitivity 94.3%) and an external validation ROC-AUC of 0.852 (Sensitivity 96.7%).
  • Location Consistency: Detection rates were consistently high across different sites: 100% for the ICA, 95% for M1, and 97% for M2 segments.
  • Clinical Utility: Notably, the model identified the LVO in all but one patient who eventually required a thrombectomy, suggesting high reliability for surgical triage.

Discussion: Analyzing the Errors

The study’s primary contribution is the identification of specific factors that lead to AI misclassification:

The Image Quality Bottleneck

A significant finding was that misclassified cases (both FP and FN) were associated with lower window settings. This indicates that poor contrast enhancement or a low signal-to-noise ratio in the CTA scan directly impairs the AI's ability to accurately segment and identify occlusions. This mirrors the challenges faced by human radiologists when interpreting suboptimal scans.

Clinical Confounders

Smoking history emerged as a significant factor in model failure; 100% of False Negative cases involved patients with a history of smoking, compared to only 33% of True Positives (P=0.005). Chronic vascular changes associated with smoking may alter the vessel morphology in ways that mask acute occlusions from the CNN. Additionally, tissue plasminogen activator (tPA) treatment was more frequent in False Positive cases (41%) than in True Negatives (20%), potentially due to the drug's effect on clot density or vessel appearance during the scan.

The Value of "False" Positives

Interestingly, many cases labeled as False Positives were not entirely "wrong." The model frequently flagged distal occlusions (such as the M3 segment) or severe arterial stenosis. While these did not meet the study's strict definition of LVO (ICA, M1, M2), they are clinically significant findings that warrant medical attention, suggesting the model has a broader sensitivity to vascular pathology than initially intended.

Conclusion

The LVO detection tool evaluated in this study shows high performance comparable to commercial platforms. However, the reliance on manual image windowing and the impact of image quality on accuracy highlight the need for standardized imaging protocols or more advanced, automated preprocessing techniques. Future research should focus on training models on larger, more diverse datasets to improve generalizability and to develop 3D architectures capable of handling raw CTA data without human intervention.

Summary updated

Abstract

Abstract Detection of large vessel occlusion (LVO) using machine learning on computed tomography angiography (CTA) may help stroke triage, yet applicability across varied patient and image characteristics has not been examined. The study will examine which characteristics are important when using a convolutional neural network to identify LVO on CTA. A retrospective cohort study (November 2017–May 2019) at a comprehensive stroke center evaluated 677 stroke-alerted patients with an LVO of the internal carotid artery, M1, or M2 (n=150) and a matching number without LVO were included. An Inception module-based network was trained for binary classification of LVO presence. Results were examined by LVO location, window settings, non-LVO findings, demographics, risk factors, presentation status and times, interventions, and outcomes. Three hundred patients were included (48% women; median age 65). Mean±95% CI for cross-validation test and external validation, respectively, are area under precision-recall curve 0.871±0.094 and 0.742±0.018 and area under receiver operating characteristic curve 0.920±0.051 and 0.852±0.004. 145 true positive (TP), 5 false negative (FN), 39 false positive (FP), and 111 true negative (TN) patients were identified. Significant comparisons (P<0.05) identified: lower window settings for misclassifications, smoking history for all FN versus 33% TP (P=0.005), and tissue plasminogen activator treatment for 41% FP versus 20% TN (P=0.017). Our LVO detection tool had high performance across patient characteristics with few exceptions. FP had pathology warranting detection, including distal occlusions. Lower window settings among misclassifications highlight the need for image quality when using machine learning for decision support.