Cell Manipulation and Detection Enhancement Enabled by a Microelectromagnet Integrated with a Digital Microfluidic Device

Lei Chen, Andrew C. Madison, Richard B. Fair, Z Zhu, W Zhang, X Leng, M Zhang, Z Guan, J Lu, T Duncombe, A Tentori, A Herr, N Teranishi, A Kohono, Y Ishihara, E Oda, K Arai, J Song, R Evans, Y Lin, B Hsu, D Dunlop, A Khlystov, T Tailor, V Ivanov, L Malic, T Veres, Maryamtabrizian, L Molnar, M Berhes, L Papp, N Nemeth, B Fulesdi, M Howell, A Davis, G Martin, E Brouzes, M Medkova, N Savenelli, D Marran, M Twardowski, S Arya, B Lim, A Rahman, A Rival, D Jary, C Delattre, Y Fouillet, G Castellan, H Kim, M Bartsch, R Renzi, J He, J Van De Vreugde, O Lazcka, Fjd Campo, F Muoz, H Lee, Y Liu, D Ham, R Westervelt, K Liao, H Chiu, Fan Sy, Y Tseng, P Lu, H Ma, Rwr Wallbank, R Chaji, J Li, Y Suzuki, Cwt Shields, C Reyes, G Lopez, Y Chen, P Li, P Huang, Y Xie, J Mai, M Zborowski, J Chalmers, S Ohk, A Bhunia, V Velusamy, K Arshak, O Korostynska, K Oliwa, C Adley, Q Chen, J Lin, C Gan, Y Wang, D WangBiosensors 2018 · DOI

Abstract

This work demonstrates sparse cell detection in mL samples, using magnetic bead manipulation on an Electrowetting-On-Dielectric (EWD) chip. Sparse sample detection was performed in two steps: cell capture off chip from the starting solution with a microelectromagnet and on-chip fluorescent signal detection on an EWD chip. In the first step, immunological reactions enable the binding between target cells and antibody-coated magnetic beads, which enabled sample capture with high cell survival rates. In the second step, fluorescent detection is achieved on an EWD chip via fluorescent signal measurement and two-dimensional magnetic bead concentration. Magnetic bead concentration is controlled with an integrated microelectromagnet, a planar set of half-circle-shaped current-carrying wires embedded in an actuation electrode of an EWD device. This two-dimensional wire structure serves as a microelectromagnet capable of segregating magnetic beads into an area on the order of 10 m2 with a resulting improvement in Signal-To-Noise Ratio (SNR) of 30 times. Simple device integration ensures that the magnetic bead manipulation and the EWD function can be operated simultaneously without introducing additional steps in the EWD chip fabrication process. Immunological reaction kits were selected in order to ensure the compatibility of target cells, magnetic beads and EWD functions. The magnetic bead choice ensures the binding efficiency and survivability of target cells. The magnetic bead selection and binding mechanism used in this work can be applied to a wide variety of samples with a simple switch of the type of antibody. Sparse cell fluorescent measurements with good SNR are made possible by using fluorescent stains and a method of concentrating cells attached to beads into a small detection area. Theoretical limitation of the entire sparse sample detection system is as low as 1 colony forming unit/mL (CFU/mL).
BibTeX
@inproceedings{chen2018cell,
  author = {Lei Chen and Andrew C. Madison and Richard B. Fair and Z Zhu and W Zhang and X Leng and M Zhang and Z Guan and J Lu and T Duncombe and A Tentori and A Herr and R Fair and N Teranishi and A Kohono and Y Ishihara and E Oda and K Arai and J Song and R Evans and Y Lin and B Hsu and R Fair and D Dunlop and R Fair and A Khlystov and T Tailor and V Ivanov and R Evans and L Malic and T Veres and Maryamtabrizian and L Molnar and M Berhes and L Papp and N Nemeth and B Fulesdi and M Howell and A Davis and G Martin and E Brouzes and M Medkova and N Savenelli and D Marran and M Twardowski and S Arya and B Lim and A Rahman and A Rival and D Jary and C Delattre and Y Fouillet and G Castellan and H Kim and M Bartsch and R Renzi and J He and J Van De Vreugde and O Lazcka and Fjd Campo and F Muoz and H Lee and Y Liu and D Ham and R Westervelt and K Liao and H Chiu and Fan Sy and Y Tseng and P Lu and H Ma and Rwr Wallbank and R Chaji and J Li and Y Suzuki and Cwt Shields and C Reyes and G Lopez and Y Chen and P Li and P Huang and Y Xie and J Mai and M Zborowski and J Chalmers and S Ohk and A Bhunia and V Velusamy and K Arshak and O Korostynska and K Oliwa and C Adley and Q Chen and J Lin and C Gan and Y Wang and D Wang and L Chen and R Fair and Y Wang},
  title = {{Cell Manipulation and Detection Enhancement Enabled by a Microelectromagnet Integrated with a Digital Microfluidic Device}},
  booktitle = {Biosensors},
  year = {2018},
  doi = {10.29011/2577-2260.100045},
}

Loading related content...

Figure