Categorisation of EEG suppression using enhanced feature extraction for SUDEP risk assessment

Juan C. Mier, Yejin Kim, Xiaoqian Jiang, Guo-Qiang Zhang, Samden D. LhatooBMC Medical Informatics Decis. Mak 2020 · OpenReview

TL;DR

This paper tackles the critical challenge of automatically identifying the end of postictal generalized EEG suppression (PGES) in epilepsy patients, a key indicator for Sudden Unexpected Death in Epilepsy (SUDEP) risk. By employing advanced feature extraction and machine learning models like Random Forests, they achieve promising results in accurately marking this crucial time point, paving the way for better SUDEP risk assessment.

What Problem Does This Paper Address?

Sudden Unexpected Death in Epilepsy (SUDEP) is a significant and concerning issue in the epilepsy community, yet its underlying causes remain largely unknown. Researchers are actively seeking reliable bio-markers to identify individuals at higher risk. One promising candidate is the duration of postictal generalized EEG suppression (PGES), a period of reduced brain activity following a seizure. The longer the PGES, the higher the potential SUDEP risk. However, accurately and consistently determining the end of PGES from EEG data is a complex and manual process, prone to variability among clinicians. This paper aims to automate this detection process, reducing subjectivity and improving efficiency.

Methods

The researchers developed a machine learning pipeline to automatically detect the end of PGES. Their approach involved:

  • Data Preparation: EEG data from clinically supervised seizures was segmented into various window sizes (3s, 7s, 10s, and random 1-12s) to account for temporal variations. Each snippet was labeled as containing the end of PGES (1) or not (0).
  • Feature Extraction: A rich set of 10 distinct features, rooted in fundamental EEG signal characteristics, were extracted using the pyEEG library. These features span signal processing (e.g., Power Spectral Intensity), computational geometry (e.g., Fractal Dimensions), and information theory (e.g., Entropy measures).
  • Machine Learning Models: Two classification algorithms were employed: Gradient Boosted Decision Trees (XGBOOST) and Random Forest. These models were trained on the extracted features to distinguish between snippets with and without the end of PGES.
  • Hyperparameter Tuning: A coordinate descent algorithm was used to tune the hyperparameters of the XGBOOST model to optimize its performance.

Datasets

The study utilized EEG data from 134 patients who underwent clinically supervised seizures. The data was processed into approximately 12.6 million EEG snippets across 10 channels. No new benchmark datasets were introduced; the focus was on applying machine learning to existing clinical EEG data.

Key Insights and Ideas

  • Feature Engineering is Crucial: The study highlights that the choice and extraction of relevant features from raw EEG data are paramount for successful classification. Features capturing signal complexity and irregularity proved particularly informative.
  • Random Forest's Strength: The Random Forest classifier, when trained on a comprehensive feature set, demonstrated superior performance compared to XGBOOST in this specific task.
  • Window Size Matters: The temporal aspect of EEG data is critical. While a constant 10-second window size yielded good results, exploring various window sizes and random snippets helped to capture different temporal dynamics.
  • SUDEP Risk Link: The ability to accurately mark the end of PGES is a significant step towards developing tools that can predict SUDEP risk, a crucial unmet need in epilepsy care.

Key Results

The machine learning architecture achieved a maximum Area Under the ROC Curve (AUC) of 76.02% using the Random Forest classifier trained on all extracted features with a constant 10-second EEG snippet length. The most influential features for predicting the end of PGES were SVD Entropy, Petrosan Fractal Dimension, and Power Spectral Intensity. Conversely, Higuchi Fractal Dimension, Hjorth Mobility and Complexity, and Fisher Information showed minimal contribution.

Limitations and Future Work

The authors acknowledge several limitations:

  • Data Splitting Bias: The model's performance was sensitive to how patients were split into training and testing sets, suggesting a potential source of bias.
  • Limited Feature Space: While 10 features were extracted, the authors suggest that expanding this to include more EEG features could further improve performance.
  • Hyperparameter Sensitivity: The XGBOOST model showed low sensitivity to hyperparameter tuning, with minimal improvements observed.

Future work should focus on:

  • Clinical Integration: Integrating these automated detection methods into real-time clinical settings.
  • SUDEP Risk Prediction: Utilizing the PGES duration information to develop predictive models for SUDEP risk.
  • Ensemble Methods: Exploring bagging or ensemble approaches to combine this method with other detection techniques or manual clinical assessments to create a more robust system.

Summary updated

Abstract

Sudden Unexpected Death in Epilepsy (SUDEP) has increased in awareness considerably over the last two decades and is acknowledged as a serious problem in epilepsy. However, the scientific community remains unclear on the reason or possible bio markers that can discern potentially fatal seizures from other non-fatal seizures. The duration of postictal generalized EEG suppression (PGES) is a promising candidate to aid in identifying SUDEP risk. The length of time a patient experiences PGES after a seizure may be used to infer the risk a patient may have of SUDEP later in life. However, the problem becomes identifying the duration, or marking the end, of PGES (Tomson et al. in Lancet Neurol 7(11):1021–1031, 2008; Nashef in Epilepsia 38:6–8, 1997). This work addresses the problem of marking the end to PGES in EEG data, extracted from patients during a clinically supervised seizure. This work proposes a sensitivity analysis on EEG window size/delay, feature extraction and classifiers along with associated hyperparameters. The resulting sensitivity analysis includes the Gradient Boosted Decision Trees and Random Forest classifiers trained on 10 extracted features rooted in fundamental EEG behavior using an EEG specific feature extraction process (pyEEG) and 5 different window sizes or delays (Bao et al. in Comput Intell Neurosci 2011:1687–5265, 2011). The machine learning architecture described above scored a maximum AUC score of 76.02% with the Random Forest classifier trained on all extracted features. The highest performing features included SVD Entropy, Petrosan Fractal Dimension and Power Spectral Intensity. The methods described are effective in automatically marking the end to PGES. Future work should include integration of these methods into the clinical setting and using the results to be able to predict a patient’s SUDEP risk.
BibTeX
@inproceedings{mier2020categorisation,
  author = {Juan C. Mier and Yejin Kim and Xiaoqian Jiang and Guo-Qiang Zhang and Samden D. Lhatoo},
  title = {{Categorisation of EEG suppression using enhanced feature extraction for SUDEP risk assessment}},
  booktitle = {BMC Medical Informatics Decis. Mak},
  year = {2020},
  url = {https://openreview.net/forum?id=CQNkeiJDnH},
}
Figure