Case Report: Locking Plate for Cubitus Varus Correction in a 7-Year-Old Girl With Osteogenesis Imperfecta

Hong Pan, Ruikang Liu, Saroj Rai, Jin LiFrontiers in Pediatrics 2022 · DOI

TL;DR

This case report documents the first successful surgical correction of cubitus varus (a "gunstock" elbow deformity) in a child with Osteogenesis Imperfecta (OI). By combining a lateral closing wedge osteotomy with a locking compression plate and aggressive pharmacological bone-strengthening, the team achieved stable fixation and excellent functional recovery in extremely fragile, osteoporotic bone.

What Problem Does This Paper Address?

Cubitus varus is a common complication following untreated or poorly healed elbow fractures in children. While the surgical correction (osteotomy) is well-documented in healthy children, it presents a massive challenge in patients with Osteogenesis Imperfecta (OI), also known as "brittle bone disease."

Patients with OI have significantly reduced bone mineral density (BMD) and thin cortices. Standard orthopedic fixation methods—such as Kirschner wires (K-wires) or external fixators—often fail in these patients because the bone is too weak to hold the hardware, leading to screw pullout, hardware migration, or non-union (failure to heal). This paper addresses the lack of established protocols for correcting limb deformities in this high-risk pediatric population.

Methods

The authors employed a multi-modal approach combining surgery with medical optimization:

  1. Pharmacological Intervention: Before and after surgery, the patient received calcium, vitamin D, and bisphosphonates (Alendronate and later Zoledronic acid) to increase bone mass and inhibit bone resorption.
  2. Surgical Technique: The surgeons performed a lateral closing wedge osteotomy. This involves removing a wedge-shaped piece of bone from the side of the humerus to straighten the arm. They also included a slight medial translation of the distal fragment to improve the cosmetic "bump" often left by this procedure.
  3. Fixation: Instead of standard wires, they used a 3.5 mm locking reconstruction plate. In a locking plate system, the screws thread into the plate itself, creating a "fixed-angle construct." This acts like an internal fixator, which is less dependent on the friction between the plate and the bone—a critical advantage when bone quality is poor.

Datasets

As a clinical case report, this study does not use large-scale datasets. It tracks a single 7-year-old female patient. Evaluation metrics included:

  • DXA Scans: Dual-energy X-ray absorptiometry to monitor Bone Mineral Density (BMD) z-scores.
  • MEPS: The Mayo Elbow Performance Score, a standardized clinical tool to assess pain, stability, and range of motion.
  • Radiographic Imaging: X-rays to monitor callus formation and bone healing.

Key Insights and Ideas

  • The "Internal Fixator" Advantage: The core "aha moment" is the application of locking plate technology to OI-related cubitus varus. Because the screws lock to the plate, the stability of the construct is maintained even if the bone-screw interface is weak, effectively bypassing the primary challenge of osteoporotic bone.
  • Biological Optimization: The authors emphasize that surgery alone is insufficient. They postponed the corrective surgery for 8 months while using bisphosphonates to improve the patient's BMD (moving from a severe z-score of -5 to -3 before the elbow surgery).
  • Medial Translation: By shifting the distal bone fragment medially during the wedge closure, the surgeons avoided the "lateral condylar prominence," a common aesthetic failure where the elbow looks unnaturally wide after straightening.

Key Results

  • Functional Recovery: The patient achieved a nearly normal range of motion (ROM) and was able to perform daily activities without pain.
  • Quantitative Success: The patient earned a Mayo Elbow Performance Score (MEPS) of 95 points, categorized as "Excellent."
  • Bone Density Improvement: Over the course of the treatment and follow-up, the patient's BMD z-score improved from a baseline of -5 to -1.8, indicating a significant response to the pharmacological therapy.
  • Long-term Stability: At the 18-month follow-up (after the hardware was removed), the correction remained stable with no signs of recurrence or fracture.

Limitations and Future Work

  • Sample Size: As a single case report (N=1), the results may not be generalizable to all types of OI or all pediatric patients.
  • Hardware Evolution: The authors used a reconstruction locking plate but noted that an anatomic locking plate (specifically shaped for the distal humerus) might provide even better stability if available.
  • Drug Delivery: Intravenous bisphosphonates were only introduced later in the treatment; the authors suggest that starting with IV administration might be more effective for improving bone quality earlier.
  • Economic Analysis: Locking plates are significantly more expensive than K-wires. Future studies should investigate the cost-effectiveness of this approach versus the risk/cost of revision surgeries required by cheaper, less stable methods.

Summary updated

Abstract

<b>Background:</b> Cubitus varus deformity is a common complication of untreated elbow fractures in children. However, cubitus varus in osteogenesis imperfecta (OI) children is a rare but challenging situation. To the author's knowledge, this is the first study discussing the correction of cubitus varus deformity in patient with OI. <b>Case Presentation:</b> Here we report a case of a 7-year-old OI girl with cubitus varus deformity due to a supracondylar fracture of humerus 3 year ago. The patient's parent gave a history of supracondylar fracture of left humerus in 2015. Without medical intervention, the patient was admitted into our institution for corrective surgery with the diagnosis of osteogenesis imperfecta and cubitus varus deformity in the left arm. <b>Result:</b> Medications including calcium, vitamin D and bisphosphonates were administered before the corrective surgery of cubitus varus, and a single locking plate was used to fixate the osteotomy. After the surgery, the appearance and range of motion (ROM) of the left arm was almost normal. Combined with gradual rehabilitation, the ROM of the left arm was normal without pain during daily use within the 1-year follow up. The hardware was removed as the nailing of the forearm fractures was performed at the same time. In the latest follow-up in September 2021, the appearance and ROM of the left arm was normal. <b>Conclusion:</b> Cubitus varus is a common deformity in children with elbow injuries, but it presents a challenging situation in compound fractures in OI patients. Locking plate combined with meticulous pharmacological intervention provides a good option for corrective surgery of cubitus varus in patients with OI.
BibTeX
@inproceedings{pan2022case,
  author = {Hong Pan and Ruikang Liu and Saroj Rai and Jin Li},
  title = {{Case Report: Locking Plate for Cubitus Varus Correction in a 7-Year-Old Girl With Osteogenesis Imperfecta}},
  booktitle = {Frontiers in Pediatrics},
  year = {2022},
  doi = {10.3389/fped.2021.781703},
}
Figure