Calibration of the Instrumental Response of Insight-HXMT/HE CsI Detectors for Gamma-Ray Monitoring

Qi Luo, J. Y. Liao, Xufang Li, Gang Li, Juan Zhang, Congzhan Liu, Xiao‐Bo Li, Yue Zhu, Cheng-Kui Li, Yue Huang, Mingyu Ge, Y. P. Xu, Zhengwei Li, Ce Cai, Shuo Xiao, Qi-Bin Yi, Yifei Zhang, S. L. Xiong, Shu ZhangarXiv 2020 · DOI · arXiv

Abstract

The CsI detectors of the High Energy X-ray Telescope of the Hard X-ray Modulation Telescope (HXMT/CsI) can be used for gamma-ray all-sky monitoring and searching for the electromagnetic counterparts of gravitational wave sources. The instrumental responses are primarily obtained via Monte Carlo simulations using the Geant4 tool and a detailed mass model of both the satellite and its payloads. This model is updated and validated using Crab pulse emissions from various incident directions. Both the Energy-Channel (E-C) relationship and energy resolution are calibrated across two working modes (Normal-Gain and Low-Gain) covering different energy ranges. Simulative spectral analyses indicate that HXMT/CsI constrains spectral parameters significantly better in high-energy bands. Joint spectral analyses of ten bright Gamma-Ray Bursts (GRBs) observed simultaneously with Fermi/GBM, Swift/BAT, and Konus-Wind show that the GRB flux measured by HXMT/CsI is systematically higher by $7.0\pm8.8\%$ than other instruments, while providing superior constraints on high-energy spectral parameters.

Introduction

In space-based high-energy astronomy, a detector's utility is defined by its "response matrix"—the mathematical translation of raw electronic signals (channels) into actual photon energies. For the Insight-HXMT (Hard X-ray Modulation Telescope), this is a complex task because the Cesium Iodide (CsI) detectors are embedded within a sophisticated satellite structure.

The Insight-HXMT satellite layout showing the High Energy (HE), Medium Energy (ME), and Low Energy (LE) detector arrays.

Before a gamma-ray photon reaches a detector, it may interact with the satellite's hull, solar panels, or other instruments, leading to scattering or absorption. To account for these effects, researchers must develop a precise "mass model" of the entire spacecraft. Furthermore, on-board electronics drift over time due to temperature fluctuations and aging, meaning the E-C relationship requires constant monitoring to ensure reliable data for multi-messenger astronomy.

Methodology

The researchers employed a multi-pronged approach to calibrate the instrumental response:

  1. Monte Carlo Simulation (Geant4): Transport of millions of particles was simulated through a detailed virtual model of the Insight-HXMT satellite.
  2. Mass Model Refinement: Using the Crab pulse emission as a "standard candle," researchers compared observed count rates from different directions to simulations. They iteratively refined the mass model until the intrinsic scatter ($S_u$) was reduced to 0.26, well below the target threshold of 0.3.
  3. Dual-Mode Calibration: The detectors operate in Normal-Gain (NG) for 80–800 keV and Low-Gain (LG) for 200–3000 keV. Background emission lines identified during blank-sky and Earth-occultation periods served as fixed energy markers for E-C calibration.
  4. Cross-Calibration: Joint spectral analyses were performed on ten bright GRBs observed simultaneously by Insight-HXMT and other major missions like Fermi/GBM and Swift/BAT.
Flowchart of the calibration process for the Insight-HXMT/HE response matrix, incorporating mass model refinement and Crab calibration.

Key Results and Insights

  • Mass Model Impact: The study highlights that for gamma-ray monitoring, the satellite itself acts as part of the detector system. The updated model successfully accounts for the complex "footprints" left by photons as they penetrate the spacecraft.
  • Electronic Drift: While energy resolution remains stable, the E-C relationship evolves significantly over months, particularly in Low-Gain mode. This necessitates a monthly calibration update strategy to maintain precision.
  • Flux Consistency: The GRB flux measured by Insight-HXMT/CsI is systematically higher by $7.0 \pm 8.8\%$ compared to other instruments. While a slight offset exists, it remains within acceptable statistical margins for cross-mission calibration.
  • Spectral Constraints: In joint fittings with Fermi/GBM, the inclusion of HXMT data significantly improved the precision of the high-energy spectral index ($\beta$). For certain bursts, the error bars on $eta$ were reduced by nearly half, demonstrating HXMT's vital role in the MeV range.

Conclusion

The rigorous calibration of the Insight-HXMT/HE CsI detectors has enabled high-fidelity monitoring of the most violent explosions in the universe. By combining sophisticated simulations with in-orbit observations, the mission provides a powerful tool for all-sky gamma-ray monitoring and gravitational wave counterpart searches. Future work will focus on improving the response for incident angles greater than $90^\circ$ and potentially automating the tracking of electronic drifts.

Reference: Luo, Q., et al. (2020). Calibration of the Instrumental Response of Insight-HXMT/HE CsI Detectors for Gamma-Ray Monitoring. arXiv:2005.01367v1 [astro-ph.IM].

Summary updated

Abstract

The CsI detectors of the High Energy X-ray Telescope of the Hard X-ray Modulation Telescope (HXMT/CsI) can be used for gamma-ray all sky monitoring and searching for the electromagnetic counterpart of gravitational wave source. The instrumental responses are mainly obtained by Monte Carlo simulation with the Geant4 tool and the mass model of both the satellite and all the payloads, which is updated and tested with the Crab pulse emission in various incident directions. Both the Energy-Channel relationship and the energy resolution are calibrated in two working modes (Normal-Gain mode & Low-Gain Mode) with the different detection energy ranges. The simulative spectral analyses show that HXMT/CsI can constrain the spectral parameters much better in the high energy band than that in the low energy band. The joint spectral analyses are performed to ten bright GRBs observed simultaneously with HXMT/CsI and other instruments (Fermi/GBM, Swift/BAT, Konus-Wind), and the results show that the GRB flux given by HXMT/CsI is systematically higher by $7.0\pm8.8\%$ than those given by the other instruments. The HXMT/CsI-Fermi/GBM joint fittings also show that the high energy spectral parameter can be constrained much better as the HXMT/CsI data are used in the joint fittings.
BibTeX
@misc{luo2020calibration,
  author = {Qi Luo and J. Y. Liao and Xufang Li and Gang Li and Juan Zhang and Congzhan Liu and Xiao‐Bo Li and Yue Zhu and Cheng-Kui Li and Yue Huang and Mingyu Ge and Y. P. Xu and Zhengwei Li and Ce Cai and Shuo Xiao and Qi-Bin Yi and Yifei Zhang and S. L. Xiong and Shu Zhang and Shuang‐Nan Zhang},
  title = {{Calibration of the Instrumental Response of Insight-HXMT/HE CsI Detectors for Gamma-Ray Monitoring}},
  year = {2020},
  eprint = {2005.01367},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2005.01367},
}
Figure