Block-Wise Mixed-Order Continuity Constraints for Displacement Estimation in Transcranial Ultrasound Shear Wave Elastography

Yiran Chen, Chaoyang Zhang, Huali Chu, Yichen Yan, Xiao Su, Yueyuan Wang, Lei Jiang, Meiling Liang, Hongmei Zhang, M. X. WanIEEE Trans. Instrumentation & Measurement 2026

Abstract

Transcranial ultrasound shear wave elastography (TSWE) enables noninvasive assessment of brain tissue mechanical properties for diagnosing brain diseases. Accurate shear wave displacement estimation is critical for reliable evaluation of tissue mechanics. However, the thickness and heterogeneous structure of the skull induce strong attenuation and scattering of both ultrasound and shear waves. These effects degrade ultrasound tracking quality, weaken shear wave propagation in the brain, and introduce substantial noise, thereby reducing the accuracy of shear wave displacement estimation. To address this challenge, a block-wise mixed-order continuity constraints (BW-MOUL) method is proposed. This method incorporates first- and second-order regularization to enhance displacement accuracy by improving spatial smoothness and noise suppression, while employing a block-wise matrix strategy to improve computational efficiency. In numerical simulations, cranial phantom experiments, and in <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">vivo</i> goat brain experiments, BW-MOUL demonstrated superior displacement estimation performance, thereby enhancing the accuracy of shear wave speed (SWS) estimation and the reliability of viscoelasticity and fluidity assessment. In simulations, BW-MOUL achieved a normalized root-mean-square error (NRMSE) of 4.03% in displacement estimation relative to the ground truth. In phantom experiments, BW-MOUL improved the particle displacement signal-to-noise ratio (PDSNR) by 5.11 dB and 3.27 dB, and increased the SWS SNR<italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">t</i> of the tumor region by 10.79 and 4.61, compared to normalized cross-correlation (NCC) and global ultrasound elastography (GLUE), respectively. In goat brain experiments, BW-MOUL yielded elasticity, viscosity, and fluidity values of 1452 Pa, 7.077 Pa·s<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">α</sup>, and 0.9291, respectively, which are consistent with reported goat brain tissue properties. Moreover, the block-wise processing strategy achieved approximately a 66-fold speedup over the global method. Overall, the BW-MOUL method demonstrates strong potential in TSWE for noninvasive diagnosis of brain diseases.
BibTeX
@article{chen2026block,
  author = {Yiran Chen and Chaoyang Zhang and Huali CHU and Yichen Yan and Xiao Su and Yueyuan Wang and Lei Jiang and Meiling Liang and Hongmei Zhang and M. X. Wan},
  title = {{Block-Wise Mixed-Order Continuity Constraints for Displacement Estimation in Transcranial Ultrasound Shear Wave Elastography}},
  journal = {IEEE Transactions on Instrumentation and Measurement},
  year = {2026},
  doi = {10.1109/tim.2026.3670595},
}

Loading related content...

Figure