Biomechanical Load of Neck and Lumbar Joints in Open-Surgery Training

Ce Zhang, Charlotte Christina Roossien, Gijbertus Jacob Verkerke, Han Houdijk, Juha M. Hijmans, Christian Greve2023

TL;DR

This study quantifies the biomechanical loads on the neck and lumbar spine during open-surgery training using inertial measurement units (IMUs) and musculoskeletal modeling. The findings reveal that while loads are lower than in heavy lifting, prolonged static postures contribute to surgeon musculoskeletal symptoms, informing the design of more effective exoskeletons.

What Problem Does This Paper Address?

Surgeons frequently experience musculoskeletal symptoms (MSS), particularly in the neck and lower back. This is often attributed to prolonged static postures and unfavorable working positions during surgery. While exoskeletons show promise in reducing joint and muscle load, existing designs are primarily focused on heavy lifting tasks. There's a need to understand the specific biomechanical demands of open surgery to design tailored exoskeletons that can effectively reduce the risk of MSS for surgeons without hindering their delicate work. This paper aims to fill this gap by quantifying the neck and lumbar joint loads and postures during open-surgery training.

Methods

The researchers employed a multi-faceted approach combining motion capture and biomechanical modeling:

  • Inertial Measurement Units (IMUs): Five Xsens MTw IMU sensors were attached to key points on the head, sternum, spine, and pelvis of surgical trainees. These sensors captured the orientation and acceleration data of these body segments at 100 Hz.
  • Musculoskeletal Modeling (OpenSim): A customized OpenSim musculoskeletal model, adapted from a validated full-body model, was used. This model excluded lower extremity muscles and intercostals to focus on the neck and trunk. It was scaled to each participant using their anthropometric data.
  • Inverse Kinematics: The IMU data was processed using OpenSim's inverse kinematics workflows to estimate the joint angles (kinematics) of the neck and lumbar spine.
  • Inverse Dynamics and Static Optimization: OpenSim's inverse dynamics were used to calculate net joint moments. To manage computational load and focus on muscle activations, the Static Optimization function was employed to estimate muscle forces at 10-second intervals.
  • Joint Reaction Force Analysis: This analysis was performed to determine the compression forces on the neck and lumbar joints.
  • Data Analysis: Kinematic and kinetic data were analyzed to determine mean working postures, range of motion, and the distribution of joint angles, moments, and compression forces over time. Histograms were used to visualize these distributions.

Datasets

The study utilized data collected from eight healthy surgical trainees. This dataset, comprising IMU-based motion capture data during simulated open-surgery training, is a novel contribution for this specific research area. No pre-existing public datasets were used for training or evaluation.

Key Insights and Ideas

  • Surgical Postures are Static but Demanding: While surgeons spend a significant portion of their time in relatively static postures, these postures involve sustained flexion in both the neck and lumbar spine, which are known risk factors for MSS.
  • Lower Loads Than Lifting, But Longer Duration: The peak joint moments and compression forces during open-surgery training are considerably lower than those experienced during heavy lifting tasks. However, the prolonged duration of these loads is a critical factor contributing to surgeon fatigue and potential injury.
  • Neck and Lumbar Flexion Dominates: The neck was predominantly in a flexed position (10-40 degrees) for over 70% of the surgery duration, and the lumbar spine was flexed (10-30 degrees) for nearly 70% of the time.
  • Exoskeleton Design Needs Nuance: Unlike exoskeletons for heavy lifting, those for surgeons require lower support torques but need to accommodate a wider range of combined neck and trunk movements (flexion, lateral bending, and rotation) to be effective and comfortable.
  • Individual Variability is Key: The significant standard deviations observed in joint angles and loads highlight the considerable inter-individual differences in surgical trainees' movements. This underscores the importance of designing customizable and adjustable exoskeletons.

Key Results

  • Neck Flexion: Surgeons spent 71.6% of the time with a neck flexion angle between 10-40 degrees. The normalized neck flexion moment was in the range of 0.04-0.06 Nm/kg for 53.8% of the duration. Neck compression forces were between 2.0-2.5 N/kg for 32.9% of the time.
  • Lumbar Flexion: Lumbar flexion was observed in the range of 10-30 degrees for 68.9% of the duration. The normalized lumbar flexion moment was between 0.4-0.6 Nm/kg for 35.5% of the time. Lumbar compression forces were between 15-20 N/kg for 38.2% of the duration.
  • Range of Motion: The neck joint exhibited a greater range of motion (ROM) than the lumbar joint, with a mean flexion/extension ROM of 102 ± 25.6 degrees.

Limitations and Future Work

The authors acknowledge several limitations:

  • Exclusion of Arm Loads: The reaction forces on the hands and the external moments generated by arm movements were not considered, potentially leading to an underestimation of lumbar joint loads. A validation study indicated this underestimation could be up to 23.8% for moments and 21.1% for compression forces.
  • Limited Sample Size: The study involved only eight participants. A larger sample size would provide more robust data on inter-individual differences and improve the accuracy of biomechanical profile estimations.

Future work should:

  • Incorporate Arm Contributions: Future studies should account for the contribution of arm segments in kinetic analyses to provide a more complete picture of spinal loading.
  • Design Customizable Exoskeletons: The findings suggest that exoskeletons should be designed with adjustable support forces and ranges of motion to cater to individual surgeons' needs and anatomical characteristics.
  • Consider Different Surgical Types: The study focused on open surgery. Future research could investigate biomechanical loads in other surgical modalities, such as laparoscopic surgery, which may involve different postures and workloads.