BICEP Array: a multi-frequency degree-scale CMB polarimeter

H. Hui, P. A. R. Ade, Zeeshan Ahmed, R. Aikin, Kate D. Alexander, D. Barkats, Steve J. Benton, Colin A. Bischoff, James J. Bock, Rachel Bowens-Rubin, Justus A. Brevik, Immanuel Buder, Eric Bullock, V. Buza, Jake Connors, James Cornelison, B. P. Crill, M. Crumrine, M. Dierickx, Lionel Duband, Cora Dvorkin, Jeff P. Filippini, Stefan Fliescher, J. Grayson, Grantland Hall, Mark Halpern, S. Harrison, S. R. Hildebrandt, Gene Hilton, K. D. Irwin, J. Kang, Kirit S. Karkare, E. Karpel, Jonathan Kaufman, Brian Keating, Sinan Kefeli, Sarah A. Kernasovskiy, J. M. Kovac, Chao‐Lin Kuo, Nicole Larson, K. Lau, E. M. Leitch, M. Lueker, K. G. Megerian, Lorenzo Moncelsi, Toshiya Namikawa, C. B. Netterfield, H. T. Nguyen, Roger O'brient, R. W. Ogburn, Stephen Palladino, C. Pryke, B. Racine, S. Richter, A. Schillaci, Robert Schwarz, Chris D. Sheehy, Ahmed Soliman, T. St. Germaine, Z. Staniszewski, Bryan Steinbach, Rashmi Sudiwala, Grant P. Teply, Keith L. Thompson, J. E. Tolan, C. Tucker, Anthony D. Turner, Caterina Umiltà, Abigail G. Vieregg, A. Wandui, Alexis C. Weber, Don Wiebe, Justin Willmert, Chin Lin Wong, Wai Ling K. Wu, E Yang, K. W. Yoon, Cheng Zheng2018 · DOI

TL;DR

The BICEP Array is a new, highly sensitive instrument designed to map the polarization of the Cosmic Microwave Background (CMB) across multiple frequencies. This advanced polarimeter aims to push the limits of our understanding of the early universe, particularly by searching for the faint B-mode polarization signature predicted by inflationary cosmology.

What Problem Does This Paper Address?

The early universe is thought to have undergone a period of rapid expansion called inflation. A key prediction of inflationary theory is the generation of primordial gravitational waves, which would leave a specific imprint on the polarization of the CMB – a faint "B-mode" signal. Detecting and characterizing this B-mode signal is a primary goal in cosmology, as it would provide direct evidence for inflation and allow us to constrain fundamental parameters like the tensor-to-scalar ratio ($r$). However, this B-mode signal is extremely weak and can be easily mimicked by polarized foreground emissions from our own galaxy (dust and synchrotron radiation). To disentangle these signals, cosmologists need highly sensitive instruments that can observe the CMB at multiple frequencies to effectively model and subtract foregrounds. The BICEP/Keck Array program has been at the forefront of this effort, and the BICEP Array represents the next generation, building on the success of its predecessors with increased sensitivity and frequency coverage.

Methods

The BICEP Array is a sophisticated instrument designed for high-sensitivity CMB polarization measurements. Key methodological aspects include:

  • Multi-frequency Observation: The instrument utilizes four refractive telescopes, each optimized for specific atmospheric windows at the South Pole, covering frequencies from 30/40 GHz up to 220/270 GHz. This broad frequency coverage is crucial for foreground subtraction.
  • Modular Receiver Design: Building on the BICEP3 design, the BICEP Array employs a modular approach. Each receiver is a self-contained cryostat housing optics, detectors, and readout electronics. This modularity facilitates upgrades and maintenance.
  • Advanced Optics: The telescopes use simple, diffraction-limited refractive optics with large-diameter alumina lenses. These are cooled to 4 K to minimize thermal loading.
  • Cryogenic System: A multi-stage cryogenic system, including a 4He/3He/3He sorption fridge, cools the focal plane to ultra-low temperatures (250 mK) to minimize detector noise.
  • High-Density Detector Arrays: The focal planes are populated with a large number of antenna-coupled transition-edge sensor (TES) bolometers. A key upgrade is the use of 6-inch silicon wafers, allowing for a higher detector count per module compared to previous generations.
  • Time-Domain Multiplexing (TDM) Readout: A highly multiplexed readout system, similar to BICEP3, is used for the lower frequency receivers. For the higher frequency receivers, advanced technologies like thermal kinetic inductance detectors (TKIDs) and microwave SQUID multiplexing (µMUX) are being developed to handle the even larger detector counts.
  • Magnetic Shielding: Extensive magnetic shielding is implemented at various levels (receiver, module) using superconducting niobium and high-permeability materials to mitigate spurious signals caused by the Earth's magnetic field.

Datasets

Not discussed in the paper. The paper focuses on the instrument design and its projected performance, not on data analysis from existing datasets.

Key Insights and Ideas

  • The Power of Multi-Frequency: The paper strongly emphasizes that multi-frequency observations are not just beneficial but essential for accurately measuring the faint CMB B-mode signal. By observing at 30/40, 95, 150, and 220/270 GHz, the BICEP Array can effectively differentiate between the CMB signal and polarized Galactic dust and synchrotron emission.
  • Scaling Up Detector Technology: The move to 6-inch silicon wafers for detector fabrication is a significant step. This allows for a much higher density of detectors on the focal plane, directly translating to increased sensitivity and mapping speed.
  • Sophisticated Cryogenics for Extreme Sensitivity: Achieving the required sensitivity necessitates pushing the boundaries of cryogenic engineering. The multi-stage sorption fridge and careful thermal design are critical for keeping detector noise to an absolute minimum.
  • The Importance of Magnetic Shielding: The paper highlights the often-overlooked challenge of external magnetic fields affecting sensitive SQUID readout electronics. The detailed magnetic shielding strategy is a testament to the meticulous engineering required for these experiments.
  • Incremental but Significant Progress: The BICEP Array represents a clear evolutionary step from BICEP2 and BICEP3, incorporating lessons learned and leveraging advancements in detector technology and cryogenic systems to achieve a substantial leap in sensitivity.

Key Results

  • Projected Sensitivity: The BICEP Array is projected to reach a sensitivity to the tensor-to-scalar ratio ($r$) of $\sigma(r) \sim 0.003$ by the end of its planned observing program. This is a significant improvement over previous experiments.
  • Detector Count: The instrument will house over 30,000 detectors across its four receivers.
  • Frequency Coverage: The BICEP Array covers a broad range of frequencies from 30/40 GHz to 220/270 GHz, enabling robust foreground mitigation.
  • Improved Fabrication: The use of 6" wafers allows for higher detector counts per module, with the 95 GHz receiver housing ~3500 detectors compared to 2560 in BICEP3.

Limitations and Future Work

  • Delensing Dependence: The ultimate sensitivity to $r$ is dependent on the level of "delensing" that can be achieved. This involves using higher-resolution maps (potentially from the South Pole Telescope) to subtract the B-mode signal caused by gravitational lensing, allowing for a cleaner measurement of primordial B-modes.
  • Foreground Modeling: While the multi-frequency approach aids in foreground subtraction, the accuracy of the final $r$ measurement will still be influenced by the precision of Galactic foreground models.
  • Future Development for High Frequencies: The 220/270 GHz receiver, with its very large number of detector channels, requires new readout technologies (TKIDs, µMUX) that are still under development.
  • Observing Strategy: The paper outlines the planned observing strategy, which is similar to BICEP3, suggesting a continuation of established sky scanning techniques. Future work will involve optimizing these strategies for the increased sensitivity of the BICEP Array.

Summary updated

Abstract

Bicep Array is the newest multi-frequency instrument in the Bicep/Keck Array program. It is comprised of four 550mm aperture refractive telescopes observing the polarization of the cosmic microwave background (CMB) at 30/40, 95, 150 and 220/270 GHz with over 30,000 detectors. We present an overview of the receiver, detailing the optics, thermal, mechanical, and magnetic shielding design. Bicep Array follows Bicep3's modular focal plane concept, and upgrades to 6" wafer to reduce fabrication with higher detector count per module. The first receiver at 30/40GHz is expected to start observing at the South Pole during the 2019-20 season. By the end of the planned Bicep Array program, we project 0.002 &lap; &sigma;(<i>r</i>) &lap; 0.006, assuming current modeling of polarized Galactic foreground and depending on the level of delensing that can be achieved with higher resolution maps from the South Pole Telescope.
BibTeX
@misc{hui2018bicep,
  author = {H. Hui and P. A. R. Ade and Zeeshan Ahmed and R. Aikin and Kate D. Alexander and D. Barkats and Steve J. Benton and Colin A. Bischoff and James J. Bock and Rachel Bowens-Rubin and Justus A. Brevik and Immanuel Buder and Eric Bullock and V. Buza and Jake Connors and James Cornelison and B. P. Crill and M. Crumrine and M. Dierickx and Lionel Duband and Cora Dvorkin and Jeff P. Filippini and Stefan Fliescher and J. Grayson and Grantland Hall and Mark Halpern and S. Harrison and S. R. Hildebrandt and Gene Hilton and K. D. Irwin and J. Kang and Kirit S. Karkare and E. Karpel and Jonathan Kaufman and Brian Keating and Sinan Kefeli and Sarah A. Kernasovskiy and J. M. Kovac and Chao‐Lin Kuo and Nicole Larson and K. Lau and E. M. Leitch and M. Lueker and K. G. Megerian and Lorenzo Moncelsi and Toshiya Namikawa and C. B. Netterfield and H. T. Nguyen and Roger O'brient and R. W. Ogburn and Stephen Palladino and C. Pryke and B. Racine and S. Richter and A. Schillaci and Robert Schwarz and Chris D. Sheehy and Ahmed Soliman and T. St. Germaine and Z. Staniszewski and Bryan Steinbach and Rashmi Sudiwala and Grant P. Teply and Keith L. Thompson and J. E. Tolan and C. Tucker and Anthony D. Turner and Caterina Umiltà and Abigail G. Vieregg and A. Wandui and Alexis C. Weber and Don Wiebe and Justin Willmert and Chin Lin Wong and Wai Ling K. Wu and E Yang and K. W. Yoon and Cheng Zheng},
  title = {{BICEP Array: a multi-frequency degree-scale CMB polarimeter}},
  year = {2018},
  doi = {10.1117/12.2311725},
}
Figure