Beyond Fidelity: Evaluating Synthetic Medical Imaging Data

Seyed Kahaki, Alexander R. Webber, Tahsin Rahman, Elim Thompson, Jana Delfino, Aldo BadanoarXiv 2026

TL;DR

Synthetic medical images might look perfect to the human eye, but "looking real" is a dangerous metric for clinical safety. This paper introduces ScoreCard, an open-source toolkit that moves beyond visual fidelity to evaluate synthetic data across seven critical dimensions—ensuring that AI-generated patients aren't just pretty pictures, but anatomically sound and statistically diverse datasets.

What Problem Does This Paper Address?

In the world of medical AI, data is the new gold, but it’s buried under mountains of privacy regulations and the sheer rarity of certain diseases. To bridge this gap, researchers use Synthetic Medical Imaging Datasets (SMD)—artificially generated images that mimic real patients.

The problem? We’ve been grading these "AI hallucinations" using the wrong rubric. Most evaluations rely on "fidelity" metrics like Fréchet Inception Distance (FID), which essentially ask, "Does this look like a real photo?"

But in medicine, a synthetic mammogram can look visually stunning while being anatomically impossible or systematically biased against a specific demographic. If you train a diagnostic tool on data that "looks right" but lacks the messy, diverse reality of human biology, the resulting AI could fail when it matters most. The authors tackle the lack of a systematic, clinically-minded framework for auditing these synthetic datasets.

Methods

The authors operationalize the "7Cs" framework, a multi-dimensional approach to data quality:

  1. Congruence: How well do the synthetic distributions align with real ones?
  2. Coverage: Does the synthetic data capture the full range of human variation, or just a narrow "safe" slice?
  3. Completeness: Is the necessary metadata (age, sex, scanner type) present?
  4. Consistency: Is the quality stable across different subgroups?
  5. Constraint: Does the image follow the laws of biology (e.g., no floating organs)?
  6. Comprehension: Is the generation process transparently documented?
  7. Compliance: Adherence to legal and ethical standards (noted as a human responsibility).

The ScoreCard Toolkit is a modular Python pipeline that automates this. It takes real and synthetic data, extracts features using everything from classic texture analysis to modern "Foundation Models" (like DINOv2), and spits out a structured report.

Figure 1: Overview of the Synthetic Data ScoreCard Pipeline. The pipeline accepts patient and synthetic data (including PNG images, NIfTI volumes, shape masks in .mat/HDF5 format, and metadata in .csv/JSON/XML format) as inputs. A Feature Extraction Engine processes both patient and synthetic data, producing intermediate feature representations. These features are passed to a Metrics Calculation module that computes scores across the various synthetic data evaluation quality dimensions. Results are stored in JSON format and used to generate the final Scorecard report. Feature extraction strategies may include knowledge-based methods (texture, color, GLCM, Gabor), deep learning models (ResNet-50), and general-purpose foundation models (DINOv2).

Datasets

The toolkit was stress-tested across three very different imaging worlds:

  • Digital Pathology (WSI): Used the MoNuSeg dataset (real) vs. images generated by HistoGen.
  • Digital Mammography: Used the EMBED dataset (real) vs. two synthetic sets: CSAW-syn (Diffusion-based) and VMLO-syn (StyleGAN2-based).
  • Head CT: Used the RSNA Intracranial Aneurysm challenge data (real) vs. synthetic scans generated via the XCIST simulation pipeline.

Key Insights and Ideas

  • Fidelity is a False Friend: A dataset can have high "realism" scores while failing "Coverage." This is known as mode collapse, where the AI gets really good at drawing one type of patient but ignores the rest of the population.
  • The "Anatomical Law" Check: By formalizing a Constraint Violation Rate (CVR), the authors can mathematically flag images that break biological rules—something standard computer vision metrics completely miss.
  • Foundation Models as Evaluators: The paper highlights that general-purpose AI models (like DINOv2) are surprisingly good at spotting subtle distributional shifts in medical data that handcrafted features might overlook.
  • Metadata is Data: A synthetic image without a synthetic patient history is half-useless. ScoreCard explicitly audits the "Completeness" of the accompanying data files.

Key Results

The results revealed "invisible" flaws in popular synthetic datasets:

  • Pathology: Fine-tuning is non-negotiable. A "coarsely" trained model had an Intersection over Union (IoU) of only 0.231 with real data, while a fine-tuned version jumped to 0.650.
  • Mammography: Geography matters. A model trained on Swedish data actually matched a US reference set better than a model trained on Vietnamese data, likely due to regional differences in imaging hardware or patient populations.
  • Head CT: The simulation-based synthetic data showed a massive "Coverage" gap (IoU as low as 0.033). It captured only a tiny fraction of the intensity variation found in real clinical scans, appearing "too clean" compared to the noisy reality of a hospital.
Visual and quantitative comparison across modalities

Limitations and Future Work

The authors are refreshingly honest about the hurdles ahead:

  • The Reference Problem: ScoreCard is only as good as the "Real Data" you compare it to. If your reference set is biased, your evaluation will be too.
  • Human in the Loop: The toolkit provides the numbers, but it doesn't replace expert clinical judgment. It’s a "scorecard," not a "pass/fail" stamp.
  • Closing the Loop: The next big step is proving that a "good" ScoreCard result actually leads to better performance when that synthetic data is used to train a diagnostic AI.

The code is available for the community to poke at: https://github.com/DIDSR/ScoreCard.

Summary updated

Abstract

The growing use of synthetic medical imaging datasets (SMD) in the development and evaluation of machine learning models has motivated interest in systematic methods to assess dataset quality across different imaging modalities. Common evaluation strategies rely heavily on fidelity-oriented metrics developed for general computer vision and may not capture clinically relevant properties such as anatomical plausibility, dataset coverage, metadata completeness, subgroup consistency, or documentation quality. We present the ScoreCard Toolkit that operationalizes six of the seven dimensions found within the 7Cs approach for SMD evaluation across Congruence, Coverage, Completeness, Consistency, Constraint, and Comprehension. The ScoreCard Toolkit provides a modular pipeline for preprocessing, feature extraction, metric computation, visualization, and structured scorecard generation. This approach complements standard fidelity-based evaluation by exposing quality characteristics not captured by those measures alone, including constraint violations, anatomically implausible shape artifacts, and metadata-related consistency issues. The toolkit supports appearance, texture, and shape features and is designed to accommodate additional feature representations, including radiomic features, deep-learning embeddings, and foundation-model representations. We demonstrate the end-to-end workflow across three imaging modalities: synthetic digital pathology whole-slide image patch data, synthetic digital mammography, and synthetic head CT. Across all three modalities, the resulting scorecards reveal dataset-specific quality characteristics, such as distributional biases and coverage gaps that may impact their effectiveness for model development or testing. ScoreCard provides a practical, extensible, and modality-agnostic approach for evaluating and transparently reporting SMD quality.
BibTeX
@misc{kahaki2026beyond,
  author = {Seyed Kahaki and Alexander R. Webber and Tahsin Rahman and Elim Thompson and Jana Delfino and Aldo Badano},
  title = {{Beyond Fidelity: Evaluating Synthetic Medical Imaging Data}},
  year = {2026},
  eprint = {2611.28154},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.28154},
}
Figure