Benchmarking VLM Medical Hallucination across 5 Modalities

Zhixing Cao, Yusen PengarXiv 2026

Imagine you’re a doctor looking at a complex MRI. You’re tired, the coffee is cold, and you ask an AI assistant for a second opinion. It answers with total confidence—but it’s completely wrong. In the world of Vision-Language Models (VLMs), we call this a "hallucination."

A new paper from researchers at the Technical University of Munich and Ohio State University introduces Multi-Med, a benchmark designed to find exactly where these medical AI models trip up across five different types of medical imaging.

TL;DR

Medical AI models are surprisingly easy to "gaslight" into seeing things that aren't there, especially when given a leading question. This paper introduces a balanced benchmark across five modalities (like ECGs and pathology) and reveals that general-purpose AI often outperforms specialized medical models when it comes to staying grounded in reality.

What Problem Does This Paper Address?

We’ve seen VLMs like GPT-4o do incredible things, from writing code to describing photos. Naturally, we want to point them at medical data. However, medicine is a high-stakes environment where "making things up" can be fatal.

The authors identified a major gap: existing tests for medical AI are "X-ray heavy." They focus mostly on chest X-rays and ignore other critical data like heart rhythms (ECGs) or microscopic tissue samples (pathology). Furthermore, these tests don't always try to actively trick the models. If a model is just memorizing patterns rather than "understanding" the image, it might fail when faced with a misleading prompt.

Methods

The researchers built a "Question Curation Pipeline" to move beyond simple "What is this?" questions. They developed four distinct ways to test a model’s grip on reality:

  1. Baseline: Standard medical questions to check basic knowledge.
  2. Modality Mismatch: Showing the model an X-ray but asking it a question about a CT scan. A robust model should say, "Wait, this isn't a CT."
  3. Incorrect Premise: Asking a question that contains a false assumption (e.g., "What's wrong with the kidney?" when the image shows a healthy kidney).
  4. False Suggestion: The ultimate "gaslighting" test. The prompt explicitly tells the model a lie (e.g., "This scan shows pneumonia") and then asks a follow-up question to see if the model blindly agrees.
Fig. 2. Question Curation Pipeline.

Datasets

The authors introduced Multi-Med, a benchmark of 1,000 image-question pairs. Unlike previous datasets, it is meticulously balanced across five modalities:

  • CT (Computed Tomography)
  • MRI (Magnetic Resonance Imaging)
  • CXR (Chest X-ray)
  • ECG (Electrocardiogram) — Newly emphasized
  • Pathology (Microscopic tissue slides) — Newly emphasized

The images were sourced from established public archives (like RadImageNet and PathVQA) but re-curated to ensure the questions were challenging and the distribution was even.

An overview of the five modalities and four question types included in the Multi-Med benchmark.

Key Insights and Ideas

  • The "Illusion of Progress": One of the most striking findings is that general-purpose models (like Qwen3-VL) often beat models specifically fine-tuned on medical data (like LLaVA-Med). Fine-tuning might help a model learn medical jargon, but it often makes the model less robust against hallucinations. It "forgets" how to be skeptical.
  • The Power of Suggestion: Models are incredibly suggestible. When given a "False Suggestion," the average accuracy plummeted to just 15.8%. Most models would rather agree with a lying prompt than trust the pixels in front of them.
  • Architecture > Size: We often think "bigger is better," but the data shows that a well-architected 4-billion parameter model (Qwen3-VL-4B) can significantly outperform a 27-billion parameter model (MedGemma-27B).
  • Modality Gap: AI is much better at interpreting traditional radiology (X-rays, MRIs) than it is at reading ECGs or pathology slides. This suggests our current models haven't "seen" enough of these specific data types during training.

Key Results

  • Top Performers: Qwen3-VL-8B took the crown with 72.9% overall accuracy, slightly edging out GPT-4o (70.2%).
  • Statistical Ties: Interestingly, the performance gap between the top three or four models wasn't statistically significant, suggesting we are hitting a temporary plateau in medical VLM reasoning.
  • The Scaling Curve: While accuracy generally improves with model size, the "return on investment" varies wildly between model families.
Fig. 4. Model size-accuracy tradeoff.

Limitations and Future Work

The authors are upfront about the fact that 1,000 samples is just the tip of the iceberg. Medicine contains thousands of rare diseases and dozens of other modalities (like ultrasound or EEG) not covered here.

Future work will likely focus on "clinical safety" rather than just "accuracy." It’s one thing for a model to get a multiple-choice question right; it’s another for it to provide a safe, reasoned explanation that a doctor can actually use. For now, the takeaway is clear: don't take an AI's medical advice at face value—it might just be telling you what it thinks you want to hear.

Summary updated

Abstract

Hallucinations in Vision-Language Models (VLMs) within the medical domain remain a difficult and not well-understood problem, and it is still unclear where these models break down. Although several benchmarks targeting medical hallucination have been introduced, they often lack broad coverage across different medical imaging modalities. We introduce Multi-Med, a medical hallucination benchmark containing 1,000 image-question pairs spanning five distinct modalities. Using this benchmark, we perform an in-depth experimental study of 10 widely used VLMs across five modalities and four question categories. Our findings indicate that model performance differs substantially depending on the imaging modality and question type, and that the differences among the best-performing models are not statistically significant.