NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

BandFocusNet: A Lightweight Model for Motor Imagery Classification of a Supernumerary Thumb in Virtual Reality

Haneen Alsuradi, Joseph Hong, Alireza Sarmadi, Robert Volcic, Hanan Salam, S. Farokh Atashzar, Farshad Khorrami, Mohamad EidIEEE Open Journal of Engineering in Medicine and Biology 2025

TL;DR

This paper introduces BandFocusNet, a novel, lightweight deep learning model that can distinguish between motor imagery (MI) of a natural thumb and a supernumerary thumb with 70.9% accuracy. This advancement is crucial for enabling more intuitive control of human augmentation technologies by differentiating neural signals associated with artificial limbs from those of natural ones.

What Problem Does This Paper Address?

Human movement augmentation, the field of enhancing human capabilities with robotic limbs or "supernumerary effectors," is rapidly advancing. However, a key challenge is enabling seamless and intuitive control. Electroencephalography (EEG) offers a promising avenue for brain-computer interfaces (BCIs) to control these augmentations via motor imagery (MI) – the mental rehearsal of a movement. Yet, a critical hurdle is reliably differentiating the neural signals associated with imagining the movement of a supernumerary effector from that of a natural limb. This distinction is vital for avoiding control conflicts and ensuring the user feels a sense of agency over the augmented limb. Previous research often compared MI to a resting state, which doesn't fully address the concurrency issue. This paper aims to bridge this gap by developing a model that can specifically differentiate MI of a supernumerary thumb from that of a natural thumb.

Methods

The researchers propose BandFocusNet, a lightweight deep learning model designed to process EEG data. Its architecture is built to capture the temporal, spectral, and spatial characteristics of EEG signals. Key components include:

  • Multiband Temporal Convolution: The model processes EEG data across three specific frequency bands: delta (1-4 Hz), theta (4-8 Hz), and alpha (8-13 Hz). This is motivated by prior research suggesting these bands are relevant for MI.
  • Channel Attention (Squeeze-and-Excitation Block): This mechanism dynamically weighs the importance of different EEG channels, allowing the model to focus on the most informative ones for classification.
  • Layer Normalization: Used instead of batch normalization, which the authors suggest can improve generalization in leave-one-subject-out scenarios.

The model's performance was evaluated using a leave-one-subject-out cross-validation strategy, which is a more rigorous test of generalizability than standard k-fold cross-validation, especially for BCI applications where individual variability is high. To ensure the model's findings are trustworthy, they employed explainability analysis (Shapley values) to identify influential brain regions and event-related spectral perturbation (ERSP) analysis to validate these findings.

Datasets

The study utilized an EEG dataset collected from twenty human subjects. These subjects participated in a virtual reality (VR) experiment where they:

  1. Observed movements of their virtual natural thumb and a virtual supernumerary thumb.
  2. Engaged in motor imagery (MI) of these observed movements.

This dataset was used for both training and evaluating BandFocusNet and baseline models. No new benchmark dataset was introduced; rather, an existing experimental paradigm was used.

Key Insights and Ideas

  • Differentiating Supernumerary vs. Natural MI is Possible: The core finding is that distinct neural signatures exist for imagining the movement of a supernumerary thumb compared to a natural one, and these can be reliably classified.
  • Frontal Lobe Dominance: Explainability analysis revealed that the frontal regions of the brain (both left and right) are particularly influential in distinguishing between the two types of MI.
  • Absence of Embodiment: ERSP analysis showed increased delta and theta power in the frontal regions during natural thumb MI, but not during supernumerary thumb MI. This suggests a potential lack of "embodiment" – the feeling of the supernumerary limb being part of one's own body – for the artificial limb.
  • Lightweight and Effective: BandFocusNet achieves competitive accuracy with significantly fewer parameters than other state-of-the-art models, making it more practical for real-time BCI applications.
  • Frequency Band Importance: While all tested frequency bands (delta, theta, alpha) contribute, removing any single band only slightly reduced accuracy, indicating their combined effect is crucial. Incorporating higher bands (beta, gamma) did not improve performance and slightly decreased it.

Key Results

  • Classification Accuracy: BandFocusNet achieved an average classification accuracy of 70.9% using leave-one-subject-out cross-validation. This outperformed baseline models like EEGConformer (67.42%), CapsuleNet (67.51%), and ATCNet (68.90%).
  • Model Efficiency: BandFocusNet uses approximately 47,908 parameters, which is at least 3.5 times fewer than the next most complex model (ATCNet).
  • Neural Validation: ERSP analysis confirmed significant differences in delta/theta power between natural and supernumerary thumb MI in the frontal ROIs (p < 0.013 for left, p < 0.001 for right).

Limitations and Future Work

  • Limited MI Types: The study focused on distinguishing MI of the supernumerary thumb from the natural thumb but did not extensively investigate the classification of specific movements (flexion/extension) of the supernumerary thumb, where accuracy was lower.
  • Dataset Size: The dataset comprised only 20 subjects, which limits the generalizability and rigor of the findings. A larger dataset could improve classification accuracy and validation.
  • Virtual Reality vs. Real World: The experiment was conducted in a VR environment. The absence of sensory feedback (e.g., weight, physical attachment) in VR might influence how MI signals translate to real-world control of physical supernumerary limbs.
  • Future Directions:
    • Investigate more complex MI tasks for directional control of the supernumerary thumb, potentially requiring longitudinal training.
  • Expand the dataset size to enhance generalizability.
  • Compare neural signatures of MI for supernumerary effectors in both virtual and real environments to understand transferability.
  • Explore the impact of physical attributes and individual MI skill on classification accuracy.

Summary updated

Abstract

<i>Objective:</i> Human movement augmentation through supernumerary effectors is an emerging field of research. However, controlling these effectors remains challenging due to issues with agency, control, and synchronizing movements with natural limbs. A promising control strategy for supernumerary effectors involves utilizing electroencephalography (EEG) through motor imagery (MI) functions. In this work, we investigate whether MI activity associated with a supernumerary effector could be reliably differentiated from that of a natural one, thus addressing the concern of concurrency. Twenty subjects were recruited to participate in a two-fold experiment in which they observed movements of natural and supernumerary thumbs, then engaged in MI of the observed movements, conducted in a virtual reality setting. <i>Results:</i> A lightweight deep-learning model that accounts for the temporal, spatial and spectral nature of the EEG data is proposed and called BandFocusNet, achieving an average classification accuracy of 70.9% using the leave-one-subject-out cross validation method. The trustworthiness of the model is examined through explainability analysis, and influential regions-of-interests are cross-validated through event-related-spectral-perturbation (ERSPs) analysis. Explainability results showed the importance of the right and left frontal cortical regions, and ERSPs analysis showed an increase in the delta and theta powers in these regions during the MI of the natural thumb but not during the MI of the supernumerary thumb. <i>Conclusion:</i> Evidence in the literature indicates that such activation is observed during the MI of natural effectors, and its absence could be interpreted as a lack of embodiment of the supernumerary thumb.
BibTeX
@article{alsuradi2025bandfocusnet,
  author = {Haneen Alsuradi and Joseph Hong and Alireza Sarmadi and Robert Volcic and Hanan Salam and S. Farokh Atashzar and Farshad Khorrami and Mohamad Eid},
  title = {{BandFocusNet: A Lightweight Model for Motor Imagery Classification of a Supernumerary Thumb in Virtual Reality}},
  journal = {IEEE Open Journal of Engineering in Medicine and Biology},
  year = {2025},
  doi = {10.1109/ojemb.2025.3537760},
}
Figure