AVI-HT: Adaptive Vision-IMU Fusion for 3D Gloved Hand Tracking

Ziyi Kou, Ankit Kumar, Mia Huang, Taylor Niehues, Vatsal Mehta, Ergys Ristani, Li GuanNeurIPS 2026

TL;DR

When you grab a coffee mug or turn a screwdriver, your fingers curl out of sight of a headset camera, causing standard 3D hand-tracking systems to guess wildly. Researchers at Meta Reality Labs built AVI-HT, a system that fuses headset video with tiny motion sensors on a lightweight glove, dynamically shifting trust to the glove’s "sense of motion" the exact moment a finger disappears from view. It makes dexterous virtual reality and robot teleoperation remarkably resilient to visual blind spots.

Figure 1: 3D hand tracking from egocentric vision and on-glove IMUs. (Left) Our multi-modal data capture setup that consists of an egocentric camera and a data sensing glove with 12 6-DoF IMU sensors. (Right) Qualitative comparison on 4 egocentric frames. For each frame, the top row shows an inset hand diagram. The bottom row shows the corresponding 3D hand pose tracking overlaid for UMETrack and AVI-HT against ground truth. The tracking results by AVI-HT are closely aligned with the ground truth, while the vision-only baseline deviates substantially. The top yellow patches highlight the activated IMU sensors by the adaptive attention module of AVI-HT, indicating the regions with greater reliance on IMU signals over egocentric vision. Best viewed in color.

What Problem Does This Paper Address?

Tracking hands in 3D is crucial for AR/VR and teaching robots to manipulate objects. Doing this solely with headset (egocentric) cameras hits a wall during the moments that matter most: hand-object interactions. The very act of grasping an object hides your fingers from the camera, leaving thousands of kinematically plausible ways your unseen fingers could be bent.

Wearable Inertial Measurement Units (IMUs)—tiny accelerometers and gyroscopes—don't care about line-of-sight. However, 9-DoF IMUs (which include magnetometers) get thrown off by indoor magnetic interference from electronics and furniture, while simpler 6-DoF IMUs lack a global spatial anchor and slowly drift over time. Essentially, cameras know where your hand is in the room, and IMUs know how your hidden fingers are flexing. Until now, fine-grained fusion of these two complementary signals for hands has been bottlenecked by a lack of good hardware and synchronized multi-modal datasets.

Methods

AVI-HT pairs 60 Hz monochrome images from a Meta Quest headset with 200 Hz signals from 12 compact 6-DoF IMUs distributed across the back of a sensing glove.

While the model uses standard vision backbones (ResNet for real-time AR/VR via the UMETrack hand model; ViT-Huge for offline mesh reconstruction via MANO) and a standard Transformer to encode temporal IMU windows, the magic happens in the novel hierarchical cross-sensor attention fusion module:

Figure 2: Overview of AVI-HT. A Vision Encoder converts the egocentric image into a global visual token Fvis. An IMU Encoder embeds a 14 timestamp temporal window from 12 on-glove sensors into per-sensor tokens {sk} via a transformer encoder and signal head. The two token sets are fused through a hierarchical cross-sensor attention module. A kinematic prior mask aggregates attended features based on physical sensor-joint proximity while the attention scores averaged for each IMU sensor represent its adaptive importance. The fused representation is decoded by a regression head into either MANO or UMETrack parameters for hand tracking.
  • Topology-Aware First-Level Attention: A global visual token is combined with 12 per-sensor IMU tokens. Because an IMU on your pinky says very little about your thumb, the authors inject a kinematic prior mask based on shortest-path distances along the hand skeleton. When a finger is occluded in the image, attention naturally shifts toward the physically closest IMU.
  • Balanced Second-Level Attention: Because 12 IMU tokens easily outvote a single visual token in standard softmax attention, a second stage pools the 12 IMU tokens into one summary token. A self-attention layer then cleanly arbitrates between "vision" and "inertia" on equal footing.

Datasets

  • Training: An internal dataset of ~8 million glove images paired with IMU streams and marker-based Motion Capture (MoCap) ground truth.
  • DexGloveHOI (New Benchmark): Because existing hand datasets are mostly vision-only and recorded in low-occlusion studio setups, the authors introduced DexGloveHOI strictly for evaluation (completely disjoint subjects and tasks from training). It features 4 participants performing 17 everyday manipulation tasks—like using scissors, turning screwdrivers, and building with Legos—yielding 100K+ egocentric frames and 2.4M synchronized IMU samples.
Figure 3: Overview of DexGloveHOI dataset. (Left) Sample egocentric images showing diverse activities captured with the data sensing glove. (Top right) Distribution of activity categories in Dex- GloveHOI. (Bottom right) Key statistics of dataset. Each frame is paired with synchronized on-glove IMU signals and ground truth from MoCap system in both MANO and UMETrack representations.

Key Insights and Ideas

  • Naive fusion can actually hurt: Simply concatenating vision and IMU features barely improves over vision alone. When a hand is clearly visible, vision is crisp, and indiscriminately mixing in noisy IMU data muddies the waters. Adaptive attention works because it learns to ignore the IMUs until visual evidence drops out.
  • Biology shows up in the attention weights: Ablating sensors one finger at a time shows each IMU helps its own finger most, with noticeable spillover to neighboring fingers—mirroring real-world biomechanical coupling where adjacent fingers share tendons and move together.
  • The wrist anchors the fingers: Even during heavy tool use, the wrist almost always stays visible to the headset camera. Vision locks down global 3D position and rotation at the wrist, completely curing the drift problem of the 6-DoF finger IMUs.

Key Results

  • Real-time Tracking (UMETrack): AVI-HT reduces overall mean keypoint error by 16.1% (to 10.36 mm) and fingertip error by 24.2% over the vision-only baseline, easily beating a traditional Extended Kalman Filter fusion baseline.
  • Offline Mesh Recovery (MANO): Compared to the state-of-the-art vision transformer HaMeR, AVI-HT cuts Procrustes-aligned joint error by 23.5% and vertex error by 27.3%.
  • Scaling with Occlusion: When fewer than 5 keypoints are hidden, AVI-HT beats vision-only fingertip tracking by ~3.5 mm. When 15–20 keypoints are hidden, that lead doubles to 6.20 mm (and 7.48 mm when wrist-aligned).
  • Physical Contact: Evaluated on wooden-block manipulation, AVI-HT maintains steadier finger-object contact, reducing surface displacement by 0.95 mm and cutting momentary contact losses by 8.5% (and 29.7% at a 10 mm threshold).

Limitations and Future Work

Wearing a sensor-studded black glove changes how the hand looks, creating a visual domain gap for downstream apps expecting bare skin—though the authors note photorealistic hand-avatar rendering could paint a bare hand back over the tracked pose. Furthermore, AVI-HT was trained and tested on a single glove design; developing "glove-agnostic" fusion that generalizes across different sensor layouts and hardware specs is the next frontier.

Summary updated

Abstract

We present AVI-HT, an adaptive visual-IMU fusion approach for tracking 3D hand poses by jointly modeling the egocentric images with on-glove 6-DoF IMU signals. AVI-HT significantly improved accuracy and availability, particularly in hand-object interaction (HOI) scenarios involving heavy visual occlusion. Two complementary ingredients underpin its success: (1) synchronized multi-modal training data pairing on-body vision-IMU sensor streams with ground-truth 3D hand poses from a motion-capture system, and (2) a cross-sensor deep attention mechanism that adaptively modulates the trust assigned to the vision and individual IMU sensors. To evaluate AVI-HT in real-world settings, we conduct extensive experiments on our DexGloveHOI dataset that consists of 100K+ pairwise vision-IMU samples with synchronized 3D annotated poses, in which users manipulate a variety of objects during daily tasks. We compare against multiple single- and multi-modal tracking approaches under two hand models (UmeTrack, MANO). The results show that AVI-HT reduces mean keypoint error by 16.1% and its wrist-aligned variant by 24.2% over the baselines. A hand-object contact evaluation shows that AVI-HT keeps finger contacts with the manipulated object more accurately and consistently over time, reducing contact losses by 8.5%. Ablation studies further show that our fusion design outperforms simpler schemes and that the gains grow with occlusion and hold across subjects.
BibTeX
@inproceedings{kou2026avi,
  author = {Ziyi Kou and Ankit Kumar and Mia Huang and Taylor Niehues and Vatsal Mehta and Ergys Ristani and Li Guan},
  title = {{AVI-HT: Adaptive Vision-IMU Fusion for 3D Gloved Hand Tracking}},
  booktitle = {Advances in Neural Information Processing Systems},
  year = {2026},
  url = {https://openreview.net/forum?id=CzwKVs3kov},
}
Figure