Automatic segmentation of bladder in CT images
Abstract
Segmentation of the bladder in computerized tomography (CT) images is an important step in radiation therapy planning of prostate cancer. We present a new segmentation scheme to automatically delineate the bladder contour in CT images with three major steps. First, we use the mean shift algorithm to obtain a clustered image containing the rough contour of the bladder, which is then extracted in the second step by applying a region-growing algorithm with the initial seed point selected from a line-by-line scanning process. The third step is to refine the bladder contour more accurately using the rolling-ball algorithm. These steps are then extended to segment the bladder volume in a slice-by-slice manner. The obtained results were compared to manual segmentation by radiation oncologists. The average values of sensitivity, specificity, positive predictive value, negative predictive value, and Hausdorff distance are 86.5%, 96.3%, 90.5%, 96.5%, and 2.8 pixels, respectively. The results show that the bladder can be accurately segmented.
BibTeX
@article{shi2009automatic,
author = {Feng Shi and Jie Yang and Yuemin Zhu},
title = {{Automatic segmentation of bladder in CT images}},
journal = {Journal of Zhejiang University. Science A},
year = {2009},
doi = {10.1631/jzus.a0820157},
}Ask Althea to put this paper to the test.
Loading related content...