Automatic radiotherapy plan emulation for 3D dose reconstruction to enable big data analysis for historically treated patients

Ziyuan Wang, Tanja Alderliesten, Marco Virgolin, Arjan Bel, Brian V. Balgobind, Peter A. N. Bosman2019

TL;DR

This paper introduces an automated pipeline to recreate radiation therapy plans on surrogate CT scans for historical patient data. This automation is crucial for generating large datasets needed to understand the long-term effects of radiation therapy, ultimately aiming to improve future treatment strategies.

What Problem Does This Paper Address?

Understanding the long-term health consequences (late adverse effects) of radiation therapy (RT) is vital for improving future treatment plans. This requires analyzing large datasets that correlate radiation dose with these effects. However, for patients treated before the late 1990s, detailed 3D dose information is often unavailable because only 2D radiographs were used for planning, and no 3D imaging (like CT scans) was acquired. To reconstruct this missing 3D dose information, researchers emulate the original RT plan onto a surrogate 3D anatomy. This emulation process is currently a manual, labor-intensive task that involves an RT planner visually matching the historical plan's geometry to the surrogate anatomy. This bottleneck severely limits the scale at which dose reconstruction data can be generated, hindering large-scale analysis.

Methods

The authors propose an image-processing pipeline to automate the RT plan emulation process. The pipeline focuses on abdominal RT plans with anterior-to-posterior (AP) and posterior-to-anterior (PA) field setups, commonly used for childhood cancer survivors.

The core steps are:

  1. Automatic Landmark Detection: The pipeline first identifies anatomical landmarks on 2D radiographs (specifically, Digitally Reconstructed Radiographs or DRRs derived from CT scans). This involves a series of image processing techniques, including signal summation along vertical and horizontal directions, thresholding, and peak detection to locate rib cage boundaries, vertebral column estimations, intervertebral discs, and vertebral bone boundaries.
  2. Parameter Derivation: These detected landmarks are then used to derive parameters necessary for plan emulation. This includes calculating rib cage width, vertebral column length, and identifying specific landmark points (e.g., middle-left and middle-right points on vertebrae).
  3. Plan Emulation: The derived parameters are used to calculate the RT parameters (isocenter, collimator angle, jaw positions, and MLC positions) for the emulated plan on the surrogate CT. This involves accounting for differences in vertebral column bending and scaling factors between the reference and surrogate DRRs.

Datasets

The study utilized CT scans from 15 pediatric patients (aged 2-6 years) who received abdominal RT for cancer between 2002 and 2018. For validation, three historical-like Wilms' tumor RT plans were selected as reference plans. The pipeline was tested by applying automatic emulation on surrogate CT scans from four other patients for each reference plan, resulting in a total of 12 automatic emulations.

Key Insights and Ideas

  • Automation is Key for Big Data: The most significant insight is that automating the plan emulation step is critical for enabling large-scale dose reconstruction. This directly addresses the bottleneck that has prevented researchers from generating the vast datasets needed for advanced analysis.
  • Landmarks as Geometric Anchors: The pipeline effectively leverages anatomical landmarks detected on 2D projections (DRRs) as robust geometric anchors to guide the complex process of translating a 2D plan onto a 3D surrogate anatomy.
  • Accounting for Anatomical Variations: The method explicitly accounts for variations in vertebral column bending and scaling between the reference and surrogate anatomies, which is crucial for accurate plan emulation.
  • Potential for Broader Application: While tested on specific abdominal RT plans, the underlying principles of landmark detection and parameter transformation are presented as being extensible to other RT plans and anatomical regions.

Key Results

The automated plan emulation pipeline was validated by an experienced RT planner who visually assessed 12 cases.

  • High Approval Rate: 11 out of 12 automatically emulated plans were approved, with the planner considering them to be of the same quality as manually emulated plans.
  • Quantitative Comparison: On average, the differences in plan parameters between automatically and manually emulated plans were small:
  • Isocenter location: 4.3 mm (standard deviation 3.0 mm)
    • Collimator angle: 1.6° (standard deviation 1.1°)
    • Field size along RL: 2.0 mm (standard deviation 1.7 mm)
    • Field size along FH: 3.6 mm (standard deviation 2.6 mm)
  • Single Failed Case: One case was identified as failed, where the isocenter was off by 8.8 mm and the collimator angle by 3°. This failure was attributed to significant anatomical differences (a curved vertebral column in the surrogate) that the current method struggled to compensate for.

Limitations and Future Work

  • DRR Generation Automation: The current pipeline still relies on an external tool (Oncentra TPS) for DRR generation. Future work aims to automate this step by using pre-delineated organ contours to automatically determine an isocenter.
  • Limited Scope of Current Method: The landmark detection method is currently limited to AP-PA field setups and was specifically tested on Wilms' tumor plans.
  • Robustness to Anatomical Variations: The single failed case highlights that significant anatomical deviations between the reference patient and the surrogate can still pose challenges. The authors suggest that in such cases, the surrogate CT might not be a good representative.
  • Future Improvements: The authors plan to improve the robustness of the pipeline, implement quality control for emulated plans, and validate the method on a larger and more diverse set of CT scans and reference plans (including right-sided flank plans). A quantitative assessment of landmark detection accuracy is also suggested.

Summary updated

Abstract

3D dose reconstruction for radiotherapy (RT) is the estimation of the 3D radiation dose distribution patients received during RT. Big dose reconstruction data is needed to accurately model the relationship between the dose and onset of adverse effects, to ultimately gain insights and improve today’s treatments. Dose reconstruction is often performed by emulating the original RT plan on a surrogate anatomy for dose estimation. This is especially essential for historically treated patients with long-term follow-up, as solely 2D radiographs were used for RT planning, and no 3D imaging was acquired for these patients. Performing dose reconstruction for a large group of patients requires a large amount of manual work, where the geometry of the original RT plan is emulated on the surrogate anatomy, by visually comparing the latter with the original 2D radiograph of the patient. This is a labor-intensive process that for practical use needs to be automated. This work presents an image-processing pipeline to automatically emulate plans on surrogate computational tomography (CT) scans. The pipeline was designed for childhood cancer survivors that historically received abdominal RT with anterior-to-posterior and posterior-to-anterior RT field set-up. First, anatomical landmarks are automatically identified on 2D radiographs. Next, these landmarks are used to derive parameters needed to finally emulate the plan on a surrogate CT. Validation was performed by an experienced RT planner, visually assessing 12 cases of automatic plan emulations. Automatic emulations were approved 11 out of 12 times. This work paves the way to effortless scaling of dose reconstruction data generation.
BibTeX
@misc{wang2019automatic,
  author = {Ziyuan Wang and Tanja Alderliesten and Marco Virgolin and Arjan Bel and Brian V. Balgobind and Peter A. N. Bosman},
  title = {{Automatic radiotherapy plan emulation for 3D dose reconstruction to enable big data analysis for historically treated patients}},
  year = {2019},
  doi = {10.1117/12.2512758},
}
Figure