Automatic body region localization in 3D-CT images based on the improved YOLO model

Linghao Du, Rui Wang, Lin Cui, Xiaolin Min, Qingyi Liu, Yande Ren, Kai Huang, Peirui BaiMATEC 2022

Abstract

Automatic body region localization in medical three-dimensional (3D)-CT images is a critical step of computerized body-wide Automatic Anatomy Recognition (AAR) system, which can be applied for radiotherapy planning and interest slices retrieving. Currently, the complex internal structure of human body and time consuming computation are the main challenges for the localization. Therefore, this paper introduces and improves the YOLO-v3 model into the body region localization for these problems. First, seven categories of body regions in a CT volume image I are defined based on the modification version of our previous work. Second, an improved YOLO-v3 model is trained to classify each axial slice into one of the seven categories. Then, the effectiveness of the proposed method is evaluated on 3D-CT images that collected from 220 subjects. The experimental results demonstrate that the slice localizing error is less than 3 NoS (Number of slices), which is competitive to the state-of-the-art methods. Beyond this, our method is simple and computationally efficient owing to its less training time, and the average computational time for localizing a volume CT images is about 3 second, which shows potential for a further application.

Introduction

In clinical workflows such as radiotherapy planning and medical database retrieval, identifying specific anatomical regions within a 3D-CT scan is a foundational requirement. A single volumetric scan can contain hundreds of individual axial slices, making manual localization tedious and metadata-dependent methods (such as relying on DICOM headers) notoriously unreliable. This process, known as Automatic Anatomy Recognition (AAR), faces significant challenges due to the low contrast of soft tissues and the high structural complexity of the internal human body.

Researchers have recently adapted the YOLO-v3 (You Only Look Once) object detection framework to solve this localization problem. By treating anatomical region identification as a classification task per axial slice, the proposed method achieves high precision with remarkable computational efficiency, processing entire volumes in just a few seconds.

Anatomical Boundary Definitions

To train the model effectively, the human body is divided into seven categories based on specific anatomical landmarks. Six primary axial boundaries are defined to delineate major regions such as the Thorax, Abdomen, and Pelvis.

Table 1: Definitions of the six primary axial boundaries (TS, TI, AS, AI, PS, PI) and their corresponding anatomical landmarks.

These boundaries provide the ground truth for the classification model. For instance, the Abdominal Inferior (AI) boundary is defined at the bifurcation of the abdominal aorta into the common iliac arteries—a region known for its structural complexity and importance in vascular imaging.

Methodology: Improving YOLO-v3

The authors utilized the YOLO-v3 architecture because it considers the entire image context during prediction, which helps reduce false positives in anatomically similar slices. To better handle the fine-grained features of medical images, the underlying Darknet-53 backbone was enhanced to 60 layers. This was achieved by doubling the number of residual blocks in the final stages of the network (from 4× to 8×).

Figure 1: Representative axial CT slices showing localized anatomical regions and landmarks with yellow boundary outlines.

Key implementation details include:

  • High-Resolution Input: The model accepts raw 512×512 CT slices without resizing, preserving critical spatial information of the tissues.
  • Fault-Tolerant Training: To assist network convergence, slices immediately adjacent to a true boundary were also labeled as ground truth during the training phase, providing a margin of error for the learning process.

Results and Discussion

The model was validated on a dataset of 220 3D-CT images. The results demonstrate an average localization error of less than 3 slices (NoS). Notably, the improved architecture outperformed the standard YOLO-v3 baseline, particularly at difficult boundaries like the abdominal bifurcation, where the error dropped from 4.1 to 2.7 slices.

The system's speed is its most significant clinical advantage; it localizes a full 3D volume in approximately 3 seconds. This efficiency makes it superior to more complex hybrid models (like CNN-RNN combinations) that often require significantly more computational time and training data.

Conclusion

The improved YOLO-v3 model provides a robust and efficient solution for body region localization in 3D-CT imaging. By balancing architectural depth with global context, the system meets the precision requirements of clinical AAR while maintaining the speed necessary for real-time application. Future research will explore feature fusion techniques and the application of this model to other modalities, such as MRI and PET scans.