Automated tooth crown design with optimized shape and biomechanics properties

Xiaoxian Jin, Shengfa Wang, Jiangbei Hu, Xiaowei Xu, Yongji Shi, Haishi Yu, Jinwu Wang, Kang Li, Xiaomin Cheng, Moyu Shao, Hongkai WangFrontiers in Bioengineering and Biotechnology 2023 · DOI

Abstract

Despite the large demand for dental restoration each year, the design of crown restorations is mainly performed via manual software operation, which is tedious and subjective. Moreover, the current design process lacks biomechanics optimization, leading to localized stress concentration and reduced working life. To tackle these challenges, we develop a fully automated algorithm for crown restoration based on deformable model fitting and biomechanical optimization. From a library of dental oral scans, a conditional shape model (CSM) is constructed to represent the inter-teeth shape correlation. By matching the CSM to the patient's oral scan, the optimal crown shape is estimated to coincide with the surrounding teeth. Next, the crown is seamlessly integrated into the finish line of preparation via a surface warping step. Finally, porous internal supporting structures of the crown are generated to avoid excessive localized stresses. This algorithm is validated on clinical oral scan data and achieved less than 2 mm mean surface distance as compared to the manual designs of experienced human operators. The mechanical simulation was conducted to prove that the internal supporting structures lead to uniform stress distribution all over the model.

Introduction: The Bottleneck in Digital Dentistry

While digital dentistry (CAD/CAM) has largely replaced traditional physical molds, the design phase remains a significant bottleneck. Currently, dental technicians must manually adjust digital templates to fit a patient's unique anatomy—a process that is both time-consuming and highly subjective.

Furthermore, most existing CAD tools focus exclusively on external aesthetics. They typically produce solid crowns that can suffer from localized stress concentrations during mastication, potentially leading to premature failure.

Clinical dental scan data showing (A) the oral scan model with a missing tooth and (B) the cropped local adjacent teeth and preparation model.

This research addresses these two challenges simultaneously: automating the labor-intensive design process and engineering the internal structure of the crown to enhance its mechanical longevity.

Methods: A Multi-Stage Automated Pipeline

The proposed algorithm utilizes a multi-stage approach to automate crown design while optimizing for biomechanics.

The technical process of the automated crown design, including CSM fitting, automatic design, preparation fitting, and internal structure optimization.

1. Conditional Shape Model (CSM)

Rather than relying on generic tooth templates, the researchers developed a Statistical Shape Model (SSM) from a library of clinical scans. By defining neighboring teeth as a "father model" and the missing tooth as a "son model," the algorithm analyzes the mathematical correlation between them. This allows the system to predict a personalized crown shape that fits the specific geometry of the surrounding teeth.

2. SDF-Based Preparation Fitting

To ensure a perfect fit onto the "finish line" (the margin of the prepared natural tooth), the team employed a Signed Distance Function (SDF). This technique allows the base of the crown to "warp" and transition smoothly to the patient's preparation site without distorting the critical chewing surface.

3. Biomechanical Optimization

The researchers integrated Triply Periodic Minimal Surfaces (TPMS) to create a porous internal architecture. A two-step optimization process—adjusting period and wall thickness—ensures that biting forces are distributed uniformly across the crown, preventing stress concentrations in specific areas like the cusps.

Key Results and Validation

The algorithm was validated using 20 randomly selected oral scan cases, comparing automated designs against those created by experienced human operators.

  • High Geometric Accuracy: The automated designs achieved a Chamfer Distance (CD) of 0.26 ± 0.08 mm for maxillary molars and 0.28 ± 0.07 mm for mandibular molars. These results are well within the 0.5 mm threshold accepted by the American Board of Orthodontics.
  • Improved Stress Distribution: Finite element simulations confirmed that the optimized porous internal structures led to a significantly more uniform stress distribution compared to traditional solid models, which showed high stress concentrations in the cusp regions.
  • Material Efficiency: The optimized designs maintained approximately 70% porosity, reducing material usage for additive manufacturing (3D printing) without compromising structural integrity.

Conclusion and Future Directions

The "father-son" relationship established in this study demonstrates that tooth shape is mathematically correlated with its neighbors, allowing for a level of personalization unattainable with generic templates. Furthermore, the shift from purely aesthetic design to internal biomechanical engineering suggests that porosity can be a functional feature to extend restoration life.

While the current method requires manual initialization for tooth location, future work aims to automate identification. Additionally, expanding the data library and conducting real-world mechanical fatigue tests on 3D-printed crowns will be essential to validate long-term durability across diverse patient populations.

Summary updated

Abstract

Despite the large demand for dental restoration each year, the design of crown restorations is mainly performed via manual software operation, which is tedious and subjective. Moreover, the current design process lacks biomechanics optimization, leading to localized stress concentration and reduced working life. To tackle these challenges, we develop a fully automated algorithm for crown restoration based on deformable model fitting and biomechanical optimization. From a library of dental oral scans, a conditional shape model (CSM) is constructed to represent the inter-teeth shape correlation. By matching the CSM to the patient's oral scan, the optimal crown shape is estimated to coincide with the surrounding teeth. Next, the crown is seamlessly integrated into the finish line of preparation via a surface warping step. Finally, porous internal supporting structures of the crown are generated to avoid excessive localized stresses. This algorithm is validated on clinical oral scan data and achieved less than 2 mm mean surface distance as compared to the manual designs of experienced human operators. The mechanical simulation was conducted to prove that the internal supporting structures lead to uniform stress distribution all over the model.
BibTeX
@inproceedings{jin2023automated,
  author = {Xiaoxian Jin and Shengfa Wang and Jiangbei Hu and Xiaowei Xu and Yongji Shi and Haishi Yu and Jinwu Wang and Kang Li and Xiaomin Cheng and Moyu Shao and Hongkai Wang},
  title = {{Automated tooth crown design with optimized shape and biomechanics properties}},
  booktitle = {Frontiers in Bioengineering and Biotechnology},
  year = {2023},
  doi = {10.3389/fbioe.2023.1216651},
}
Figure