Abstract: The brightness and large dynamic range of BRAC should facilitate high-sensitive Ca(2+) imaging not only in single live cells but also in small living subjects.
Introduction
Real-time imaging of calcium (Ca2+) dynamics is essential for understanding cellular signaling. While fluorescence-based indicators are widely used, they are limited by phototoxicity, background autofluorescence, and signal instability. Bioluminescence Resonance Energy Transfer (BRET) offers an alternative by generating light chemically, thereby avoiding the need for external excitation. However, low signal intensity has historically limited BRET sensors to population-level measurements. In this study, Saito et al. introduce BRAC, a bioluminescent ratiometric indicator optimized for single-cell imaging.
Methods
BRAC was engineered using RLuc8 as a bioluminescent donor and Venus as a fluorescent acceptor, with a Ca2+-sensing domain (calmodulin and M13) inserted between them. To maximize the dynamic range, the researchers employed circular permutation of the Venus protein. By testing 12 different structural variants, they identified a configuration that optimized the dipole orientation of the chromophore, leading to a significant increase in BRET efficiency upon Ca2+ binding.
Results
The optimized BRAC sensor exhibited a 60% dynamic range, the largest reported for this class of indicator at the time of publication. In vitro assays determined a dissociation constant ($K_d$) of 1.9 μM, suitable for physiological monitoring. In HeLa cells, BRAC successfully captured histamine-induced Ca2+ oscillations at a temporal resolution of 1 Hz.
Furthermore, the sensor's ratiometric output (the ratio of 530 nm to 480 nm emission) provided stable, quantitative data independent of sensor concentration or cell movement. BRAC was also applied to Arabidopsis thaliana, where it successfully visualized immune-related Ca2+ bursts in leaf tissue, overcoming the significant autofluorescence challenges typical of plant imaging.
Discussion
BRAC represents a significant advancement in auto-luminescent sensor technology. Although it requires the exogenous addition of the substrate coelenterazine-h and remains dimmer than some fluorescent counterparts, its high signal-to-noise ratio and lack of phototoxicity make it ideal for sensitive or long-term imaging. Future developments focusing on the circular permutation of the luciferase donor may further enhance the brightness and utility of this platform.
Summary updated