Attenuation of Sound in Lined Air Ducts
Abstract
Theoretical predictions of the performance of silencers are apt to be difficult and unreliable, so experimental results are often very valuable. A previous paper contained curves giving the attenuation of sound with frequency in lined ducts of various widths and thicknesses of lining of rock wool. Subsequent experience has shown the need for an extension of these curves to cover thicker linings and splitters, and advantage has been taken of an opportunity to obtain further data on 16-in. splitters and air channels. New curves including these data are given for a 50% space factor, together with an extrapolation to 32-in. splitters. Thicknesses greater than 16 in. are unlikely to be used unless frequencies lower than 100 cps are important. For covering very wide frequency bands two-stage filters are recommended.
BibTeX
@article{king1958attenuation,
author = {Andrew J. King},
title = {{Attenuation of Sound in Lined Air Ducts}},
journal = {The Journal of the Acoustical Society of America},
year = {1958},
doi = {10.1121/1.1909664},