At FullTilt: Real-Time Open-Set 3D Macromolecule Detection Directly from Tilted 2D Projections

Ming-Yang Ho, Alberto BartesaghiNeurIPS 2026

TL;DR

Looking for specific proteins inside frozen cells usually requires reconstructing massive 3D volumes and crawling through them inch by inch with heavy neural networks—a process that takes anywhere from minutes to nearly an hour. FullTilt skips the 3D volume entirely, spotting 3D protein coordinates directly from the raw, tilted 2D microscope images. By ditching redundant 3D computations, it runs hundreds to thousands of times faster (under half a second!) while matching or beating state-of-the-art zero-shot accuracy.

What Problem Does This Paper Address?

To understand the machinery of life, biologists use cryogenic electron tomography (cryo-ET)—essentially a CT scan for flash-frozen cells. A microscope snaps a sequence of 2D images as the sample tilts at various angles (a tilt-series), which algorithms then reconstruct into a 3D volume called a tomogram.

Finding specific macromolecules ("particles") inside these tomograms is tough. Recent open-set detectors let you highlight just one or two example particles (visual prompts) to find all similar ones zero-shot, sparing you from retraining a model for every new protein. However, 3D tomograms are too massive to fit into GPU memory (VRAM) all at once. Existing methods have to chop the 3D volume into tiny overlapping cubes or 2D slices and process them piecemeal, creating a massive I/O bottleneck.

Figure 2: Comparison of detection mechanisms. We show existing architectures and inputs for open-set 3D macromolecule detection in cryo-ET (prompting modules omitted for simplicity). (a) TomoTwin [9] and ProPicker [11] process 3D tomograms using 3D models. Due to strict VRAM limits, they rely on sliding-window subvolume extraction, which requires extensive model I/O and bottlenecks inference speed. (b) CryoSAM [10] applies a 2D SAM model to orthogonal 2D slices of the 3D tomogram, necessitating repeated, costly model I/O operations. (c) Zeng et al. [22] apply a 2D detector to individual 2D tilt images and back-project the results into 3D space. This approach suffers from low single-image visibility and severe back-projection errors. (d) FullTilt is the first framework to process the 2D tilt-series directly into 3D detection results in an end-to-end manner.

The authors ask a deceptively simple question: since the 3D tomogram is built from the 2D tilt-series (which might only be ~41 images compared to 256+ depth slices in a tomogram), all the information is already in the 2D projections. Why not detect 3D particles directly from the 2D tilt-series in one pass?

Methods

Adapting multi-view 3D detectors from self-driving cars (like DETR3D) fails miserably here because cryo-ET images have an atrocious signal-to-noise ratio—a protein is basically invisible in a single 2D frame and only emerges when your brain (or model) integrates across multiple angles.

FullTilt builds on a standard Transformer-based object detection backbone (Swin Transformer + DETR-style 3D decoder) and introduces four specialized components to handle cryo-ET physics:

Overview of the FullTilt end-to-end architecture.
  • Tilt-Series Encoder: Fuses information across all 2D views before decoding. Because the tilt-series is aligned to a vertical axis, a particle stays on the exact same horizontal row across every tilted image. FullTilt exploits this geometry using global row attention, slashing computation compared to full cross-image attention.
  • Multiclass Visual Prompt Encoder: Takes user-supplied 2D bounding boxes (projected from 3D prompts or drawn directly on a $0^\circ$ image) and uses masked attention to distill "class prototypes" for multiple protein types simultaneously.
  • Tilt-Aware Query Initializer: Instead of guessing 3D starting points blindly, it uses the $0^\circ$ tilt image—where 2D $(x, y)$ coordinates perfectly match 3D $(x, y)$ coordinates—to anchor initial queries, setting depth $z$ to the middle plane.
  • Auxiliary Geometric Primitives ($\mathcal{G}$): Physics-based cryo-ET simulations are slow to generate. During training, FullTilt alternates between simulated protein data and on-the-fly synthetic 2D projections of simple 3D shapes (like spheres) complete with simulated occlusion and lighting artifacts, forcing the network to master multi-view 3D geometry.

Datasets

  • Training: 1,138 simulated tomograms and aligned tilt-series built from 119 protein structures using an established TEM simulator, paired with on-the-fly synthetic geometric primitives.
  • Evaluation: Zero-shot performance was tested on three public, real-world cryo-ET datasets—DS-10440 (a 6-class benchmark from the CZII CryoET Object Identification Challenge), EMPIAR-10304 (purified ribosomes), and EMPIAR-10499 (ribosomes in native cellular environments)—plus a simulated test set of 10 unseen proteins.

Key Insights and Ideas

  • 3D tomograms are computationally bloated: Reconstructed tomograms contain massive redundancy. Going straight from 2D projections to 3D boxes eliminates sliding-window patching, turning an hour-long job into a sub-second interactive click.
  • Geometry is a superpower in attention: Knowing the physical constraint of the microscope's tilt axis lets FullTilt restrict cross-view attention to corresponding rows across 40+ images, making holistic multi-view fusion affordable on a single GPU.
  • Autonomous driving models can't see through quantum noise: Off-the-shelf multi-view models (DETR3D, PETR) score near-zero on cryo-ET data unless equipped with early cross-tilt feature fusion and tilt-aware initialization.
  • One 2D box is enough: Even though a 3D prompt projects onto 40+ tilt images, ablations show you can give FullTilt a 2D bounding box on just the single $0^\circ$ tilt image with almost no drop in 3D detection accuracy.

Key Results

Runtime vs. F1 performance across three real-world cryo-ET datasets.

Figure 1: Runtime and performance comparison. FullTilt achieves inference speeds hundreds to thousands of times faster than current state-of-the-art open-set macromolecule detection methods, while delivering comparable or superior zero-shot performance across three real-world cryo-ET datasets. The exact acceleration multiplier varies based on the tilt-series and tomogram dimensions.
  • Blistering Speed & Low Memory: FullTilt runs in 0.23 to 0.51 seconds per instance using just 2.4–3.4 GB of VRAM. Compared to top open-set baselines, it is >150x–210x faster than ProPicker (~50–80s, ~12.7 GB VRAM) and >5,800x–7,490x faster than TomoTwin (~1,720–2,960s, ~20.8 GB VRAM).
  • Superior Zero-Shot Accuracy: On the challenging native-cell EMPIAR-10499 dataset (4 prompts), FullTilt hits an F1 of 0.441 and [email protected] of 0.173, handily beating TomoTwin (0.354 F1 / 0.078 mAP) and ProPicker (0.235 F1). On DS-10440, FullTilt reaches 0.221 F1, more than doubling TomoTwin (0.102 F1).
  • Effortless Multiclass Scaling: Detecting 6 protein classes at once on DS-10440 takes 0.51s—virtually identical in runtime and memory to detecting just 1 class (0.50s).

Limitations and Future Work

  • Tiny Proteins: Like many DETR-style architectures, FullTilt struggles with very small objects, scoring near-zero AP on macromolecules smaller than 100 kDa.
  • Sim-to-Real & Overfitting: Zero-shot accuracy still trails behind closed-set, fully supervised models trained directly on target datasets, largely due to the domain gap between simulated training data and messy real-world biology. Interestingly, FullTilt also underperformed baselines on simulated test data, likely because 2D and 3D models overfit to different simulation quirks (like noise statistics or placement patterns).
  • Next Steps: The authors plan to explore broader training data coverage, fine-tuning on real-world cryo-ET data, and plugging FullTilt directly into downstream subtomogram averaging pipelines to resolve high-resolution 3D protein structures.

Summary updated

Abstract

Open-set 3D macromolecule detection in cryogenic electron tomography eliminates the need for target-specific model retraining. However, strict VRAM constraints prohibit processing an entire 3D tomogram, forcing current methods to rely on slow sliding-window inference over extracted subvolumes. To overcome this, we propose FullTilt, an end-to-end framework that redefines 3D detection by operating directly on aligned 2D tilt-series. Because a tilt-series contains significantly fewer images than slices in a reconstructed tomogram, FullTilt eliminates redundant volumetric computation, accelerating inference by orders of magnitude. To process the entire tilt-series simultaneously, we introduce a tilt-series encoder to efficiently fuse cross-view information. We further propose a multiclass visual prompt encoder for flexible prompting, a tilt-aware query initializer to effectively anchor 3D queries, and an auxiliary geometric primitives module to enhance the model's understanding of multi-view geometry while improving robustness to adverse imaging artifacts. Extensive evaluations on three real-world datasets demonstrate that FullTilt achieves state-of-the-art zero-shot performance while drastically reducing runtime and VRAM requirements, paving the way for rapid, large-scale visual proteomics analysis. Code and data are available at https://github.com/Kaminyou/FullTilt.
BibTeX
@inproceedings{ho2026at,
  author = {Ming-Yang Ho and Alberto Bartesaghi},
  title = {{At FullTilt: Real-Time Open-Set 3D Macromolecule Detection Directly from Tilted 2D Projections}},
  booktitle = {Advances in Neural Information Processing Systems},
  year = {2026},
  url = {https://openreview.net/forum?id=Eirt5wZqH3},
}
Figure