Assessment of Eye Fatigue Caused by 3D Displays Based on Multimodal Measurements

Jae Won Bang, Hwan Heo, Jong-Suk Choi, Kang Ryoung Park2014

TL;DR

This paper introduces a novel multimodal approach to assess eye fatigue induced by 3D displays, combining EEG, eye blink rate (BR), facial temperature (FT), and subjective evaluation (SE). Their findings suggest that subjective evaluation (SE) is the most reliable indicator of eye fatigue, followed by facial temperature, eye blink rate, and EEG signals.

What Problem Does This Paper Address?

The increasing prevalence of 3D displays has brought user eye fatigue to the forefront as a significant health concern. This fatigue can manifest as eyestrain, dizziness, and general discomfort, often stemming from the visual system's struggle to reconcile accommodation and convergence cues in 3D environments. While previous research has explored various methods for measuring eye fatigue, many rely on single modalities (e.g., just EEG or just eye blinks) or require cumbersome sensor attachments that can introduce noise and discomfort, potentially affecting the accuracy of the measurements. This paper aims to address these limitations by proposing a more comprehensive and user-friendly multimodal approach.

Methods

The researchers developed a system that simultaneously measures four key indicators of eye fatigue:

  • Electroencephalogram (EEG) signals: Specifically, they analyzed the beta band (13-30 Hz) of EEG data, as this band is known to be more active during visual fatigue. EEG data was acquired using a low-cost Emotiv EPOC headset with 16 electrodes.
  • Eye Blink Rate (BR): A high-speed, mega-pixel camera was employed to remotely track eye blinks, allowing for convenient and accurate measurement of both eyes. This method uses sub-block based template matching and ellipse fitting to detect open and closed eyes.
  • Facial Temperature (FT): A remote thermal camera was used to measure subtle changes in facial temperature, which can be indicative of fatigue. To aid in locating the face and nose for temperature measurement, a web-camera with NIR illumination was also used.
  • Subjective Evaluation (SE): Participants completed a questionnaire with six questions, rated on a 10-point scale, to subjectively report their level of eye fatigue before and after viewing the 3D display.

The experimental procedure involved collecting baseline measurements of EEG, BR, and FT before the 3D viewing session, followed by a 30-minute 3D display viewing period. During the last minute of viewing, BR was measured again. Post-viewing, EEG and FT were measured again, and a final subjective evaluation was conducted. Statistical analyses, including T-tests, correlation matrices, and Cohen's d for effect size, were used to evaluate the relationships between these modalities and their effectiveness in measuring eye fatigue.

Datasets

Not discussed in the paper. The study involved 15 human participants.

Key Insights and Ideas

  • Multimodal approach is key: Combining multiple physiological and subjective measures provides a more robust assessment of eye fatigue than any single modality alone.
  • Subjective evaluation is highly correlated: The subjective reports of eye fatigue (SE) showed the strongest correlation with other measured modalities, suggesting it's a highly sensitive indicator.
  • Facial temperature as a fatigue indicator: Changes in facial temperature, particularly a decrease after viewing, were found to be a significant indicator of eye fatigue.
  • EEG noise challenges: While EEG is a valuable tool, the study acknowledges that facial muscle movements can introduce noise, potentially affecting the reliability of EEG signals for fatigue assessment compared to other modalities.
  • Remote sensing for user comfort: The use of remote sensing for eye blinks and facial temperature significantly enhances user comfort and reduces potential artifacts from sensor attachments.

Key Results

  • The average subjective evaluation (SE) score significantly increased after watching the 3D display (p < 0.01), indicating a higher perceived level of fatigue.
  • The amplitude of the beta band in EEG signals was generally stronger after watching the 3D display, suggesting increased brain activity associated with fatigue.
  • Eye blink rate (BR) increased by approximately 21.07% during the last minute of 3D viewing compared to the baseline, though this difference was not statistically significant (p = 0.2876).
  • Facial temperature (FT) amplitude decreased after watching the 3D display, with a highly significant p-value (0.00089), indicating a clear change associated with fatigue.
  • Effect sizes (Cohen's d): SE and FT showed large effect sizes, EEG showed a large effect size, and BR showed a medium effect size, indicating the magnitude of change observed.
  • Correlation analysis: The strongest positive correlation was found between BR and SE (0.6653), and between FT and SE (0.5491). EEG showed negative correlations with BR, FT, and SE, highlighting potential inconsistencies or noise.
  • The order of credibility for measuring eye fatigue, based on correlation with other data, was determined to be: SE > FT > BR > EEG.

Limitations and Future Work

  • System Complexity: The authors acknowledge that their current system is somewhat complicated due to the integration of multiple sensors.
  • EEG Noise: The presence of noise in EEG signals due to facial muscle movements is a noted limitation that can affect its reliability compared to other modalities.
  • Future Work: The researchers plan to simplify their data acquisition system. They also aim to perform more accurate eye fatigue evaluations by combining EEG, BR, FT, and SE using approaches like fuzzy rules or principal component analysis (PCA).