Assessing informatics students' satisfaction with a web-based courseware system

Todd R. Johnson, Jiajie Zhang, Zhihua Tang, Constance M. Johnson, James P. TurleyInt. J. Medical Informatics 2004 · DOI

TL;DR

This study evaluated the usability of Prometheus, a web-based courseware system, by surveying health informatics students. While overall satisfaction remained stable across two versions, the study highlights the critical role of user satisfaction surveys in identifying and improving the usability of educational technology, especially in demanding fields like health informatics.

What Problem Does This Paper Address?

The increasing adoption of web-based learning environments and courseware systems in higher education, particularly in specialized fields like health informatics, presents a challenge. While many studies confirm the effectiveness of distance learning, there's a notable lack of systematic research analyzing the usability of these systems from the perspective of both instructors and students. Poor usability can distract from learning objectives, negatively impact learning outcomes, and is especially critical in high-stakes environments like healthcare where clinicians need "just-in-time knowledge." This paper addresses this gap by assessing student satisfaction with a specific courseware system, Prometheus, and evaluating the impact of usability enhancements.

Methods

The study employed a user interface satisfaction survey as a core component of a comprehensive usability evaluation. The primary instrument used was the Questionnaire for User Interaction Satisfaction (QUIS) version 7.0, a well-established tool for assessing user satisfaction with computer interfaces.

The QUIS was administered to health informatics students at the University of Texas Health Science Center at Houston. The survey was configured to measure overall satisfaction and seven specific interface factors relevant to Prometheus: screen, terminology and system information, learning, system capabilities, manuals and online help, multimedia, and teleconferencing. Each interface factor was assessed through multiple sub-questions, and participants rated their satisfaction on a 9-point scale.

The study involved two administrations of the survey:

  1. Fall semester 2001: Students used Prometheus version 4.
  2. Spring semester 2002: Students used the improved Prometheus version 5.

This design allowed for a comparison of user satisfaction between the two versions, aiming to determine if the implemented usability enhancements had a measurable effect. The researchers also conducted heuristic evaluations and user tests on both versions, but this paper specifically focuses on the results from the user satisfaction surveys.

Datasets

The study did not introduce new datasets or benchmarks. Instead, it utilized data collected from health informatics students at the University of Texas Health Science Center at Houston. The participants were students officially enrolled in health informatics classes who had used the Prometheus courseware system.

Key Insights and Ideas

  • Usability is paramount, especially in demanding fields: The paper strongly emphasizes that as web-based education becomes more prevalent, particularly for clinicians needing "just-in-time knowledge," the usability of courseware systems becomes critically important. Users should focus on learning, not struggling with the technology.
  • User satisfaction surveys are valuable tools: The study demonstrates the utility of tools like the QUIS for assessing and improving courseware systems, providing a benchmark for comparison with other systems.
  • Incremental improvements don't always yield significant satisfaction gains: Despite implementing usability enhancements in version 5, the study found no statistically significant difference in overall student satisfaction compared to version 4. This suggests that major overhauls might be needed, or that new problems can be introduced when fixing old ones.
  • Specific areas of weakness persist: Even with improvements, the "Manuals and Online Help" section consistently received the lowest satisfaction ratings, indicating a persistent challenge in providing adequate support resources.
  • Conceptual issues can remain unaddressed: The paper points out that fundamental conceptual problems, such as the system's inability to distinguish between assignments and student solutions, were not resolved between versions, highlighting the need for deeper design considerations beyond surface-level interface changes.

Key Results

  • Overall Satisfaction Stable: Students generally had favorable judgments of Prometheus, and their satisfaction levels remained relatively stable across both versions.
  • Version 4 vs. Version 5:
    • The average rating for version 4 was 6.23 (S.D. = 1.43).
  • The average rating for version 5 was 6.17 (S.D. = 1.36).
  • The difference between the two versions was not statistically significant (t(79) = 0.167, P = 0.87).
  • Interface Factor Strengths and Weaknesses:
    • Version 4: Users were most satisfied with "learning complex system tasks" (average rating = 6.51) and least satisfied with "manuals and online help" (average rating = 5.37).
  • Version 5: Users gave the "multimedia feature" the most favorable judgment (average rating = 6.87) but still considered "manuals and online help" the least favorable (average rating = 5.48).
  • No Significant Differences in Factors: While ratings for individual dimensions fluctuated, none of the differences between versions reached statistical significance.
  • Matched Pairs Analysis: Analysis of the 20 participants who took both surveys showed that while ratings on the first five dimensions remained stable, their ratings for "Manuals and Online Help," "Multimedia," and "Teleconferencing" fluctuated, though not significantly.

Limitations and Future Work

Limitations:

  • Small Sample Size: The study acknowledges that the small sample size (a total of 81 participants across both surveys) limited their ability to detect small changes in satisfaction.
  • Moderate Response Rates: Response rates of 42.8% and 45% were considered moderate. The length of the survey (102 questions) was identified as a likely factor contributing to this.
  • Potential for New Problems: The authors suggest that while version 5 addressed some issues from version 4, it may have introduced new problems, such as confusing icons for file status, which could have offset perceived improvements.
  • Conceptual Design Flaws: Fundamental issues with how assignments and student submissions were handled were not resolved, indicating a need for deeper conceptual design.

Future Work:

  • Expand Studies: The authors suggest that studies like this need to be expanded to understand how clinicians learn new knowledge and techniques in the clinical arena, especially with the rise of "just-in-time education."
  • Integrate Learning and Clinical Environments: The merging of educational and clinical environments necessitates integrating learning processes into traditional clinical informatics.
  • Further Usability Research: Continued application of user-centered design methods and usability surveys is crucial for building effective courseware systems.

Summary updated

BibTeX
@article{johnson2004assessing,
  author = {Todd R. Johnson and Jiajie Zhang and Zhihua Tang and Constance M. Johnson and James P. Turley},
  title = {{Assessing informatics students' satisfaction with a web-based courseware system}},
  journal = {Int. J. Medical Informatics},
  year = {2004},
  doi = {10.1016/j.ijmedinf.2003.12.006},
}
Figure