Application of Resonant Controller for Vibration Suppression to Magnetic Levitation Pump
Abstract
The problem of the rotor mass imbalance is unavoidable in the process of mechanical manufacturing, which will lead to the vibration of the magnetic levitation pump (MLP) system with the rotational speed co-frequency. The influence of the rotor mass imbalance is first analyzed in detail in this paper by building a dynamic rotor model. The resonant controller can better filter out the rotational co-frequency signal component in the system to achieve the effect of vibration suppression. However, introducing the resonant controller will lead to the instability of the low-frequency operating conditions of MLP and the corresponding compensation scheme must be implemented. An improved resonant controller is proposed to suppress the vibration caused by the rotor mass imbalance of MLP, and the low-frequency instability is solved by reasonable phase compensation, ensuring stable operation in the full-speed domain. Adequate simulations are given to verify the effectiveness of the proposed vibration suppression scheme.