NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

Application of FBG Sensor to Safety Monitoring of Mine Shaft Lining Structure

Kun Hu, Zhishu Yao, Yanshuang Wu, Yongjie Xu, Xiaojian Wang, Chen Wang2022

TL;DR

This paper introduces a Fiber Bragg Grating (FBG) sensor system for long-term safety monitoring of mine shaft lining structures, addressing the limitations of traditional sensors in harsh underground environments. The study validates the FBG sensor's accuracy and reliability through laboratory testing and a three-year field deployment, demonstrating its effectiveness in detecting early signs of structural distress.

What Problem Does This Paper Address?

Mine shafts are critical infrastructure for coal extraction, providing essential access for transport, ventilation, and drainage. The integrity of the shaft lining structure is paramount for operational safety. However, these structures are subjected to significant external loads, including soil and water pressure, and can be further stressed by geological phenomena like stratum consolidation and settlement due to mine drainage. In certain geological conditions, particularly where a water-bearing layer directly overlies bedrock, a decrease in water level can lead to increased effective stress, causing the ground to settle. If the shaft lining, often made of reinforced concrete, cannot settle synchronously with the ground, it experiences a substantial additional vertical force, akin to negative friction on piles. This force can lead to compressive stress exceeding the concrete's limit, potentially causing rupture and severe safety hazards.

Traditional sensors like resistance strain gauges and vibrating wire sensors have been used for monitoring, but they suffer from poor stability, susceptibility to corrosion, and signal interference in the complex, humid, and electromagnetically noisy environments found in mines. This makes long-term, reliable monitoring challenging and creates a significant bottleneck in ensuring mine shaft safety.

Methods

The study proposes and validates the use of Fiber Bragg Grating (FBG) sensors for long-term safety monitoring of mine shaft lining structures. FBG sensors operate by detecting changes in the reflected wavelength of light from a grating inscribed in an optical fiber. These changes are directly related to strain and temperature variations in the fiber.

The methodology involved:

  • Laboratory Simulation: An indoor simulation test was conducted using a C50 concrete column. FBG sensors were installed on the column's surface alongside traditional resistance strain gauges. The column was subjected to graded loading (100 kN increments up to 1500 kN) to compare the strain measurements from both sensor types under transverse and vertical loading.
  • Field Monitoring System Design: Based on the engineering geological conditions of the Zhuxianzhuang coal mine's auxiliary shaft, three monitoring levels were established at different depths within water-bearing and water-resisting layers. At each level, four measuring points were set up, with both vertical and circumferential FBG strain sensors installed at each point.
  • Early Warning Value Determination: Early warning thresholds (yellow, orange, and red alerts) for vertical strain were calculated based on relevant Chinese codes for coal mine shaft design and concrete structures, considering the specific geological conditions and shaft lining properties.
  • Long-Term Data Collection and Analysis: The FBG monitoring system was deployed in the auxiliary shaft, and data was collected over more than three years (from July 2018 to December 2021). The collected strain data was analyzed to assess the shaft lining's safety status and identify trends.

Datasets

The study utilized data collected from:

  • Laboratory Concrete Column Test: Strain data from FBG sensors and resistance strain gauges under controlled loading conditions.
  • Zhuxianzhuang Coal Mine Auxiliary Shaft: Over three years of real-time vertical strain data from FBG sensors installed at three different monitoring levels.

No new benchmark datasets were introduced; the focus was on applying existing sensor technology to a real-world engineering problem.

Key Insights and Ideas

  • FBG Sensor Superiority in Harsh Environments: FBG sensors offer significant advantages over traditional strain gauges due to their immunity to electromagnetic interference, corrosion resistance, small size, and high accuracy, making them ideal for long-term monitoring in challenging mine environments.
  • High Correlation with Traditional Sensors: Laboratory tests demonstrated a very high coefficient of determination (r² > 0.998) between FBG sensor readings and resistance strain gauges, validating the FBG sensor's accuracy and reliability for concrete strain measurement.
  • Seasonal Strain Fluctuations: The monitoring data revealed that vertical strain in the shaft lining exhibits periodic fluctuations correlating with seasonal temperature changes, with an estimated strain of approximately 160 με due to temperature differences.
  • Accumulating Vertical Additional Force: Despite seasonal variations, a consistent trend of increasing vertical strain increment (approximately 0.0752 με/d) was observed, attributed to the ongoing drainage and subsequent ground settlement. This indicates a growing threat to the shaft lining's long-term stability.
  • Proactive Damage Prevention: The study highlights the importance of establishing early warning thresholds and proposes a practical preventative measure: the construction of pressure-relief grooves in the shaft lining to mitigate the impact of accumulating vertical forces.

Key Results

  • Accuracy Validation: Laboratory tests showed FBG sensors and resistance strain gauges provided very close measurements, with minimal error. The coefficient of determination (r²) for transverse strain was 0.9982, and for vertical strain, it was 0.9985.
  • Field Monitoring Performance: Over three years of monitoring, the maximum vertical tensile strain recorded was 28.73 με, and the maximum vertical compressive strain was -220.53 με at the first monitoring level. These values were consistently below the established warning thresholds across all three levels.
  • Strain Increment Rate: The vertical strain increment caused by the additional vertical force was quantified at approximately 0.0752 με/d.
  • Safety Assessment: Based on the collected data and warning values, the shaft lining structure at all monitored levels was deemed to be in a safe state during the monitoring period.

Limitations and Future Work

  • Temperature Compensation: While FBG sensors are less affected by temperature than some traditional sensors, their readings can still be influenced by temperature changes. The paper notes that adding an optical fiber thermometer adjacent to the FBG sensor could enable temperature compensation for more precise strain analysis.
  • Informatization and Intelligence: The authors suggest future work should focus on enhancing the informatization of the monitoring system. This includes integrating FBG sensors with base stations for wireless data transmission and leveraging Big Data processing for more sophisticated structural health monitoring. The concept of "intelligent FBG sensors" is proposed, capable of more advanced analysis and prediction.
  • Predictive Maintenance: While the current system provides real-time safety status, future developments could focus on more advanced predictive maintenance capabilities, anticipating potential failures before they occur.
  • Broader Application: The study demonstrates the applicability of FBG sensors for mine shaft lining, providing a foundation for their wider adoption in similar monitoring applications within the mining industry.

Summary updated

BibTeX
@misc{hu2022application,
  author = {Kun Hu and Zhishu Yao and Yanshuang Wu and Yongjie Xu and Xiaojian Wang and Chen Wang},
  title = {{Application of FBG Sensor to Safety Monitoring of Mine Shaft Lining Structure}},
  year = {2022},
  doi = {10.3390/s22134838},
}
Figure