Application of Ag/AgCl Sensor for Chloride Monitoring of Mortar under Dry-Wet Cycles

Yupeng Tian, Peng Zhang, Kaiyue Zhao, Zhenxing Du, Tiejun Zhao2020 · DOI

TL;DR

This paper investigates the performance of Ag/AgCl electrodes as chloride sensors in mortar under simulated marine environments (dry-wet cycles). The study demonstrates that these sensors can effectively monitor chloride ingress, offering a more sensitive alternative to traditional anode ladder monitoring systems, though their accuracy is influenced by environmental fluctuations.

What Problem Does This Paper Address?

Reinforced concrete (RC) structures, particularly those in coastal environments like bridges and offshore platforms, are susceptible to degradation due to chloride-induced steel corrosion. Effectively monitoring chloride ion concentration in situ is crucial for predicting and preventing this corrosion. While Ag/AgCl electrodes show promise as chloride-selective sensors due to their sensitivity, their performance under the harsh and fluctuating conditions of dry-wet cycles, common in real-world environments, has not been fully established. This paper aims to bridge this gap by evaluating the reliability and sensitivity of Ag/AgCl electrodes in mortar subjected to simulated dry-wet cycles.

Methods

The researchers prepared simple Ag/AgCl electrodes using electrochemical anodization. These electrodes, along with temperature sensors, humidity sensors, and an anode ladder monitoring system (ALS), were embedded in mortar specimens. The mortar specimens were then subjected to a controlled dry-wet cyclic process, where the surface was periodically wetted with a 5% NaCl solution and then dried. The potential response of the Ag/AgCl electrodes was continuously monitored throughout these cycles. Calibration of the Ag/AgCl electrodes was performed in synthetic pore solutions with varying NaCl concentrations. The study also compared the performance of the Ag/AgCl sensors with the ALS.

Datasets

Not discussed in the paper. The study utilizes experimental data generated from the mortar specimens and embedded sensors.

Key Insights and Ideas

  • Dry-wet cycles significantly impact sensor performance: While Ag/AgCl electrodes show a response to chloride ingress, the dry-wet cycles introduce considerable fluctuations in their potential readings, making precise quantitative measurements challenging without temperature correction.
  • Ag/AgCl sensors are more sensitive than ALS: Compared to the anode ladder monitoring system (ALS), the Ag/AgCl electrodes demonstrated higher sensitivity to chloride ion ingress, providing a more nuanced indication of chloride concentration changes.
  • Temperature correction is essential: The study highlights that temperature variations, measured by embedded sensors, significantly influence the Ag/AgCl electrode's potential. Applying temperature correction leads to a reduction in data dispersion and a more reliable estimation of chloride concentration.
  • Depth matters for chloride detection: Chloride concentration generally decreases with depth, and the Ag/AgCl electrodes at shallower depths respond more quickly to chloride ingress. Deeper sensors show a slower response, indicating the localized detection capability of these sensors.
  • Early hydration influences readings: In the initial stages of the experiment, potential fluctuations were observed, attributed to cement hydration and the formation of intermediate compounds like AgOH, which can interfere with accurate chloride measurement.

Key Results

  • Ag/AgCl electrodes exhibited a sensitive response to the ingress of chloride ions into the mortar under dry-wet cycles.
  • The potential trend of the Ag/AgCl electrodes could reflect the variation in chloride ion concentration.
  • The balance potential of the Ag/AgCl electrodes was influenced by the dry-wet cycles.
  • After applying temperature correction, the dispersion in calculated chloride concentration values was reduced.
  • The study suggests that Ag/AgCl electrodes are more sensitive to chloride than the ALS.
  • The ALS indicated that the corrosion risk for most steel bars remained below 10% until around 50 cycles, with A1 initiating corrosion at this point.

Limitations and Future Work

The authors acknowledge that the dry-wet cycles significantly affect the accuracy of the Ag/AgCl electrode test results, leading to marked fluctuations in potential readings. While the general trend of chloride ion concentration can be discerned, precisely quantifying it in real-time under these conditions remains a challenge. The study suggests that the interference from hydration and hydration products needs further consideration for accurate quantitative measurements, especially during the early hydration period. Future work could focus on developing more robust sensor designs or signal processing techniques to mitigate the impact of environmental fluctuations and improve the quantitative accuracy of Ag/AgCl sensors in complex environments. Further investigation into the underlying mechanisms causing the observed fluctuations and the development of methods to compensate for them would be beneficial.