Anomaly detection and fault diagnosis of main steam temperature of the thermal power unit based on TGAN-SATCN
Lists
Only you see this
Abstract
A deep learning anomaly detection and fault diagnosis method based on a temporal generative adversarial network (TGAN) and temporal convolutional network (TCN) is proposed to address the problems of imbalanced sample size and insufficient model accuracy in the detection and fault analysis of main steam temperature anomalies. Firstly, to address the issue of limited and imbalanced fault samples, TGAN is used to fully learn the fault sample characteristics and expand the samples. Secondly, the TCN network’s ability to mine temporal data is used for anomaly detection and fault analysis. To improve the learning ability of global feature information, a self-attention mechanism is added to TCN, and a TGAN-SATCN main steam temperature anomaly detection and fault analysis model is proposed to further enhance the model’s accuracy. Simulation experiments prove that compared to the basic TCN, the accuracy and F1 Score of the proposed TGAN-SATCN model have been improved by 7.9% and 4.8%, respectively, and have lower false detection and missed detection rates. It can accurately detect main steam temperature anomalies and diagnose the causes of faults, and has good performance in anomaly detection and fault analysis.
BibTeX
@inproceedings{su2026anomaly,
author = {Guoxin Su and Wenliang Zhang and Hong-Fu Zhang and Long Liu and Ming Su},
title = {{Anomaly detection and fault diagnosis of main steam temperature of the thermal power unit based on TGAN-SATCN}},
booktitle = {Frontiers in Energy Research},
year = {2026},
doi = {10.3389/fenrg.2026.1760638},
}