Angular Interpolation in Sparse-View Low-Dose CT Reconstruction: Placement Effects and Data-Consistency Step-Size Scaling

Yitian Tang, Yuncheng Zhang, Hualiang Wang, Zuozhu LiuarXiv 2026

TL;DR

When rebuilding medical CT scans from sparse, noisy X-ray data, simple math—specifically linear interpolation—does a shocking amount of heavy lifting before a neural network even learns a single weight. This paper untangles classical preprocessing from deep learning architecture, revealing that where you plug in that simple interpolation can make or break a complex dual-domain network. Along the way, the authors uncover a clean mathematical scaling rule that keeps physics-based correction steps stable across different image resolutions.

What Problem Does This Paper Address?

To spare patients from excess radiation, doctors can take Computed Tomography (CT) scans using fewer X-ray angles ("sparse-view") and fewer photons per angle ("low-dose"). The catch? Missing angles leave harsh streak artifacts in the final image, while low photon counts inject grainy Poisson noise.

To clean this up, researchers often build dual-domain networks—deep learning pipelines that clean up both the raw X-ray projection data (the sinogram) and the reconstructed 2D slice (the image, typically formed via a classic algorithm called Filtered Back-Projection, or FBP).

Before feeding sparse sinograms into these networks, it’s common to fill in the missing angles using basic linear interpolation. Because adjacent X-ray angles capture smoothly varying views of the same anatomy, this parameter-free guess works remarkably well. However, researchers rarely separate the credit: when a fancy dual-domain network produces a crisp scan, how much of that success comes from the neural architecture, and how much comes from where that basic interpolation was placed in the pipeline? Furthermore, when enforcing physical data consistency (making sure the final image actually matches the X-ray sensor readings), standard step-size normalizations often ignore image grid resolution, risking mathematical instability.

Methods

The authors build a testbed called DC-DuNet (Data-Consistency Dual-Domain Network) and design a controlled $2 \times 2$ ablation study to isolate preprocessing from learning.

Fig. 1. The pipeline. Sinogram refinement, detached FBP and image residual refine- ment precede DCC in attenuation units, using denoised acquired-view projections from the completed sinogram. Independent switches control sinogram initialisation ( 1⃝) and the image residual base ( 2⃝); associated inputs also change in the ablation. The adjoint symbol denotes the approximate backprojector (§2.4).

Their pipeline has three main stages:

  1. Sinogram Refinement: A U-Net predicts a residual correction on top of an initial sinogram. Switch 1 tests initializing this with zero-filling versus angular linear interpolation.
  2. Image Refinement: After converting the sinogram to an image via FBP, a second U-Net predicts image-level corrections on top of a base image. Switch 2 tests using a streaky sparse-view FBP base versus a smoother interpolated-FBP base. (Both networks also use FiLM conditioning so a single trained model can handle varying view counts and radiation doses).
  3. Data-Consistency Correction (DCC): A physics-based gradient step nudges the final image so its simulated projections match the denoised X-ray measurements. Crucially, the authors perform this step in physical attenuation units (rather than rescaled network units) and normalize the step size by both image grid width ($N$) and view count ($K$), rather than just $K$.

Datasets

  • Synthetic Procedural Phantoms: Randomised ellipse phantoms mimicking human abdominal slices ($256 \times 256$ grid, 180 train / 30 validation / 40 test slices), plus a second independently generated synthetic set to test generalization.
  • CHAOS Challenge Dataset: Real human abdominal CT scans (40 slices from 10 patients, plus 13 held-out slices from 10 other patients) resampled and passed through the same simulated parallel-beam X-ray and Poisson noise pipeline to test zero-shot transfer without retraining.

Key Insights and Ideas

  • Interpolation is a double-edged sword depending on placement: Initializing the sinogram branch with linear interpolation gives a massive boost. Doing the exact same thing for the image residual base actually hurts final performance!
  • Training schedules can fool you: Early in training, using an interpolated image base looks like the winning strategy. However, the training curves cross before epoch 9—meaning impatient hyperparameter sweeps could easily lock in the worse configuration.
  • Simpler is sometimes better: When given the exact same interpolated image base, a smaller, image-only U-Net (with 25% fewer parameters) consistently beats the full dual-domain DC-DuNet. Dual-domain complexity only pays off when paired with the right initialization at very sparse angles.
  • Grid size hides in projection math: Standard practice normalizes data-consistency steps by the number of views ($K$). By running power iteration on their projection/backprojection operators, the authors show the true dominant gain scales as $\approx 0.85 NK$. Ignoring grid width $N$ means a step size tuned on $64 \times 64$ images can blow up when applied to $256 \times 256$ images.

Key Results

  • Free lunches from classical math: Without a single learned parameter, linear interpolation cuts noise-free missing-view sinogram error by 99.7% (at 60 views) compared to zero-filling, and boosts FBP image PSNR by 4.65 dB.
  • Opposite placement effects: At 60 views and 10% dose after 20 epochs, sinogram interpolation adds +1.98 dB PSNR, whereas using an interpolated image base subtracts 2.16 dB.
  • Architecture showdowns: Combining the winning sinogram initialization with a sparse FBP image base allows DC-DuNet to beat the image-only U-Net by 0.96 dB on synthetic test data (and 1.28 dB on independent synthetic slices) at 60 views. At 120+ views, however, the simpler Image-UNet takes the lead.
Visual comparison of synthetic CT reconstructions and signed error maps across methods at 60 views and 10% dose.
  • Zero-shot real anatomy transfer: Applied to held-out CHAOS patient scans without retraining, the sinogram-initialized DC-DuNet retains a modest but consistent +0.12 dB edge (winning 13/13 slices), while the penalty for the interpolated image base vanishes to 0.00 dB.
  • Step-size stability: Using $NK$ normalization keeps PSNR stable within 0.47 dB across grid sizes ($N = 64, 128, 256$) for step weights $\lambda \in [0.1, 2.0]$, whereas pushing $\lambda$ from 2 to 3 (crossing the theoretical stability limit of $2 / 0.85 \approx 2.35$) causes an immediate 2.21 dB drop.

Limitations and Future Work

The experiments rely on 2D parallel-beam geometry, synthetic training phantoms, simulated photon noise (excluding electronic read noise and detector blur), and a fixed 20-epoch schedule with a single training seed per configuration. Future work should test whether these configuration rankings hold up under longer training schedules, multiple random seeds, real clinical raw projections, and 3D cone-beam or helical CT geometries.

Summary updated

Abstract

Dual-domain networks combine projection and image processing for sparse-view low-dose computed tomography (CT). We quantify the contribution of angular interpolation before learning and distinguish its roles in sinogram initialisation and the image residual base. On synthetic parallel-beam data, parameter-free interpolation reduces noise-free missing-view mean absolute error by 99.7% relative to zero filling at 60 views. Full-view filtered back-projection (FBP) of the jointly learned completed sinogram adds 1.27 dB of peak signal-to-noise ratio (PSNR) over interpolated FBP. In a data-consistency dual-domain network (DC-DuNet), a 2x2 configuration ablation controls branch width, depth and training schedule while varying these placements and their associated input channels. After 20 epochs, the PSNR contrasts are +1.98 dB for sinogram initialisation and -2.16 dB for the interpolated image base; the image-base ranking also reverses during training. The sinogram-initialised variant exceeds an image-only U-Net by 0.96 dB at 60 views and 10% dose, and by 1.28 dB on independently generated synthetic data. The U-Net leads at higher view counts and with a shared interpolated image base. Without retraining, the variant retains a 0.12 dB advantage on held-out CHAOS abdominal CT under simulated degradation; the image-base contrast rounds to zero. The implemented projection/backprojection pair has empirical dominant gain of approximately 0.85NK, where N is image-grid width and K acquired view count. These results distinguish interpolation placement from network architecture and support NK normalisation for step calibration.