Angular Dependence of Domain Wall Resistivity in Artificial Magnetic Domain Structures

A. Aziz, S. J. Bending, H. G. Roberts, S. Crampin, P.j. Heard, C. H. MarrowsPhysical 2006 · DOI

TL;DR

This paper presents a novel method for precisely controlling artificial magnetic domain structures in Pt/Co/Pt trilayers to study domain wall resistivity. By fabricating these structures at various angles to the current, the researchers were able to map the angular dependence of domain wall resistivity and confirm theoretical predictions, leading to a better understanding of spin transport in magnetic materials.

What Problem Does This Paper Address?

The study of domain walls in magnetic materials is crucial for advancing spintronics, with applications ranging from fundamental physics to novel logic and data storage devices. However, understanding the intrinsic transport properties of domain walls has been challenging due to the difficulty in isolating them from extrinsic effects. Theoretical models predict different signs and magnitudes for domain wall resistance, and experimental verification has been hampered by the lack of precise control over domain wall orientation and the presence of unwanted scattering mechanisms. This paper aims to overcome these limitations by creating artificial domain structures with precisely controlled geometries and orientations.

Methods

The researchers fabricated artificial magnetic domain structures in perpendicularly magnetized Pt/Co/Pt trilayers using a focused ion beam (Ga-FIB) to locally modify the magnetic anisotropy. This technique allowed them to define domain structures with arbitrary shapes and precise control over the angle of the domain walls relative to the current flow. They employed a Wheatstone bridge geometry for their transport measurements, enabling sensitive detection of resistance changes. To analyze the angular dependence of the domain wall resistivity, they developed a two-dimensional numerical model that accounts for the anisotropic resistivity tensor of the domain wall.

Datasets

Not discussed in the paper.

Key Insights and Ideas

  • Precise Control of Domain Walls: The use of Ga-FIB irradiation on capped Pt/Co/Pt trilayers provides unprecedented control over the creation and orientation of artificial magnetic domain structures, allowing for systematic studies of domain wall properties.
  • Intrinsic Domain Wall Resistivity: By carefully designing their artificial structures, the authors were able to effectively exclude extrinsic effects, enabling them to isolate and study the intrinsic domain wall resistivity.
  • Angular Dependence Explained: The experimental results for the angular dependence of domain wall resistivity are well-described by a resistivity tensor that includes both perpendicular and parallel domain wall resistivities, confirming theoretical predictions.
  • Spin-Dependent Resistivity Ratio: The study provides a quantitative estimate of the ratio of minority to majority spin carrier resistivities ($\rho_\downarrow/\rho_\uparrow \approx 5.5$), which is in good agreement with theoretical band structure calculations for similar materials.

Key Results

  • The magnetoresistance of the artificial domain structures scales linearly with the number of domain walls, confirming their intrinsic origin.
  • The angular dependence of the domain wall resistivity was mapped for angles from 0° to 60° relative to the current flow.
  • The measured domain wall resistivities were found to be $\delta\rho_{CPW} = 23.1 \pm 1.1 \times 10^{-3} \mu\Omega\text{-cm}$ and $\delta\rho_{CIW} = 3.5 \pm 0.7 \times 10^{-3} \mu\Omega\text{-cm}$.
  • The ratio of minority to majority spin carrier resistivities was deduced to be $\rho_\downarrow/\rho_\uparrow \approx 5.5$, which is higher than in bulk Co but consistent with band structure calculations.

Limitations and Future Work

The authors acknowledge that their model assumes a domain wall width of 15 nm, which is taken from previous work. Future work could involve directly measuring this width in their specific structures. They also suggest exploring the enhancement of magnetoresistive effects by fabricating nanoconstrictions within the nanowire or by reducing the wire width/domain width ratio for tilted domains. Further investigations using multiple-terminal "mesoscopic" measurements are proposed to probe transverse resistance within tilted domains and gain deeper insight into domain wall scattering theories. The potential for using domain wall angle as a control parameter in multi-state logic devices based on spin-torque transfer is also highlighted as a promising application.

Summary updated

Abstract

We exploit the ability to precisely control the magnetic domain structure of perpendicularly magnetized Pt/Co/Pt trilayers to fabricate artificial domain wall arrays and study their transport properties. The scaling behavior of this model system confirms the intrinsic domain wall origin of the magnetoresistance, and systematic studies using domains patterned at various angles to the current flow are excellently described by an angular-dependent resistivity tensor containing perpendicular and parallel domain wall resistivities. We find that the latter are fully consistent with Levy-Zhang theory, which allows us to estimate the ratio of minority to majority spin carrier resistivities, rho downward arrow/rho upward arrow approximately 5.5, in good agreement with thin film band structure calculations.
BibTeX
@inproceedings{aziz2006angular,
  author = {A. Aziz and S. J. Bending and H. G. Roberts and S. Crampin and P.J. Heard and C. H. Marrows},
  title = {{Angular Dependence of Domain Wall Resistivity in Artificial Magnetic Domain Structures}},
  booktitle = {Physical},
  year = {2006},
  doi = {10.1103/physrevlett.97.206602},
}

Loading related content...