Analysis on the radiation effects of a charge-coupled device in a space debris detection satellite in orbit

Yudong Li, Lin Wen, Jianyu Huang, Wen Yan, Keke Zhang, Qi GuoNational 2019 · DOI

Abstract

Charge-Coupled Devices (CCDs) are the primary imaging components for satellite-based space debris detection. However, the harsh space radiation environment induces effects that degrade imaging performance. This study analyzes in-orbit data from a space debris detection satellite to quantify transient effects, hot pixel generation, total ionizing dose (TID), and displacement damage. Results indicate that transient effects are primarily caused by high-energy protons within the South Atlantic Anomaly (SAA). In contrast, hot pixels result from displacement damage and accumulate linearly over time, independent of transient bursts. Early in the mission, hot pixel accumulation emerges as the dominant factor affecting detection sensitivity, preceding significant TID or charge transfer efficiency (CTE) degradation.

Introduction

Space-based optical sensors are critical for tracking space debris, yet they operate in a high-radiation environment. High-energy particles can cause temporary "glitches" or permanent physical damage to CCD sensors. While laboratory simulations provide baseline expectations, real-world in-orbit data is essential for accurate risk assessment and maintenance planning. This paper examines the radiation response of a 1024×1024 back-illuminated CCD on a Chinese experimental satellite launched in 2013.

Methodology

The research utilized image sequences captured at 8, 39, 70, and 101 days post-launch. The analysis involved:

  1. Artifact Isolation: Matlab-based processing was used to remove stars, background noise, and actual debris to isolate radiation-induced signals.
  2. Spatial Correlation: Transient events were mapped against the satellite’s orbital position to identify geographical radiation hotspots, specifically the South Atlantic Anomaly (SAA).
  3. Temporal Tracking: The growth of hot pixels—pixels exhibiting abnormally high dark current—was monitored over the 101-day period.
  4. Global Health Metrics: Dummy pixels and star point spread functions (PSF) were analyzed to evaluate cumulative effects like TID and CTE degradation.

Results and Discussion

Transient Effects and the South Atlantic Anomaly

Transient effects appear as random bright spots or streaks in individual frames. The study found a strong correlation between the frequency of these events and the satellite’s passage through the SAA, a region where Earth's radiation belt dips closest to the surface.

Figure 3: Distribution of transient effects across an image sequence, showing a Gaussian-like peak corresponding to the core of the SAA.

As shown in Figure 3, the number of transient effects spikes significantly as the satellite enters the SAA, reaching a peak before returning to baseline levels. These are attributed to transient ionization caused by high-energy protons.

Hot Pixel Accumulation

Unlike transient noise, hot pixels represent permanent displacement damage in the silicon lattice. These pixels maintain high dark current levels across multiple frames and mission phases.

Figure 6: Linear accumulation of hot pixels over the first 101 days in orbit for two different integration times (0.3s and 0.7s).

Figure 6 demonstrates that the number of hot pixels increases linearly with time in orbit. This steady growth suggests that displacement damage occurs continuously, even at relatively low particle fluences. Notably, there was no spatial correlation between transient bursts and new hot pixels, confirming that the two phenomena arise from distinct physical interactions (ionization vs. lattice displacement).

Sensor Health and Detection Performance

During the first 100 days, the CCD's global parameters remained remarkably stable. Analysis of dummy pixels showed no significant shift in operating voltages, and star images maintained their symmetry, indicating that Charge Transfer Efficiency (CTE) had not yet degraded significantly. However, the increasing density of hot pixels poses an immediate threat to detection sensitivity, as they can be mistaken for faint debris or increase the overall noise floor.

Conclusion

This in-orbit analysis confirms that hot pixels are the primary radiation-induced challenge for space debris detection in the early stages of a mission. While transient effects from the SAA cause significant short-term noise, the linear accumulation of hot pixels dictates the long-term degradation of detection performance. These findings provide a data-driven basis for orbital risk assessment and the design of more radiation-resilient space-based imaging systems.

Summary updated

Abstract

电荷耦合器件(CCD)æ˜¯å«æ˜Ÿåº”ç”¨çš„ä¸»æµæˆåƒå™¨ä»¶ï¼Œå ¶å—ç©ºé—´è¾å°„çŽ¯å¢ƒå½±å“æ˜“äº§ç”Ÿè¾å°„æ•ˆåº”ï¼Œå¯¼è‡´å«æ˜Ÿæˆåƒæ€§èƒ½é€€åŒ–ï¼Œå› æ­¤CCDçš„åœ¨è½¨è¾å°„æ•ˆåº”åˆ†æžå¯¹å«æ˜Ÿåœ¨è½¨é£Žé™©è¯„ä¼°ã€åœ¨è½¨ç»´æŠ¤å ·æœ‰é‡è¦æ„ä¹‰ã€‚é’ˆå¯¹ç©ºé—´ç¢Žç‰‡æŽ¢æµ‹è¯•éªŒå«æ˜ŸæˆåƒCCD在轨出现的辐射效应,通过在轨图像数据计算,对辐射作用于CCDå¯¼è‡´çš„çž¬æ—¶æ•ˆåº”ã€çƒ­åƒç´ ã€ç”µç¦»æ€»å‰‚é‡æ•ˆåº”å’Œä½ç§»æŸä¼¤è¿›è¡Œäº†ä¼°ç®—ã€‚åˆ†æžè®¤ä¸ºçž¬æ—¶æ•ˆåº”ä¸»è¦æºäºŽå—å¤§è¥¿æ´‹å¼‚å¸¸åŒºå† é«˜èƒ½è´¨å­å ¥å°„å™¨ä»¶å¯¼è‡´çš„çž¬é—´ç”µç¦»ä½œç”¨ï¼›çƒ­åƒç´ æºäºŽè´¨å­è¾å°„å¯¼è‡´çš„å•ä¸ªåƒç´ ä½ç§»æŸä¼¤ï¼Œä¸”æ•°é‡éšç€åœ¨è½¨æ—¶é—´çš„ç´¯ç§¯ä¸æ–­å¢žåŠ ï¼Œä¸Žçž¬æ—¶æ•ˆåº”æ— æ˜Žæ˜¾çš„ç›¸å ³æ€§ï¼›åœ¨è½¨åˆæœŸç´¯ç§¯çš„ç”µç¦»æ€»å‰‚é‡æ•ˆåº”å’Œä½ç§»æŸä¼¤å¹¶ä¸çªå‡ºï¼›çƒ­åƒç´ æ˜¯å½±å“æŽ¢æµ‹å™¨å ‰ç”µæŽ¢æµ‹æ€§èƒ½çš„ä¸»è¦é—®é¢˜ï¼Œåœ¨è¾ƒä½Žç²’å­æ³¨é‡æ—¶å°±æ¯”è¾ƒæ˜¾è‘—ã€‚ä¸Šè¿°å·¥ä½œä¸ºå«æ˜Ÿåœ¨è½¨é£Žé™©è¯„ä¼°ä¸Žè¿è¡Œç®¡ç†æ”¶é›†äº†æ•°æ®ä¾æ®ï¼Œå¹¶åˆæ­¥å½¢æˆäº†é’ˆå¯¹åœ¨è½¨è¿è¡Œå ‰ç”µæŽ¢æµ‹è½½è·è¾å°„æ•ˆåº”åˆ†æžæ–¹æ³•ï¼Œå¯ä¸ºå¤©åŸºç›®æ ‡æŽ¢æµ‹å«æ˜Ÿæˆåƒå™¨ä»¶çš„åœ¨è½¨è¾å°„æ•ˆåº”åˆ†æžã€æŠ—è¾å°„è®¾è®¡æä¾›å‚è€ƒã€‚
BibTeX
@inproceedings{li2019analysis,
  author = {Yudong LI and Lin WEN and Jianyu HUANG and Wen Yan and Keke Zhang and Qi Guo},
  title = {{Analysis on the radiation effects of a charge-coupled device in a space debris detection satellite in orbit}},
  booktitle = {National},
  year = {2019},
  doi = {10.11834/jrs.20197144},
}
Figure