Analysis of the image of pion-emitting sources in source center of mass frame

Yan-Yu Ren, Qichun Feng, Wei‐Ning Zhang, Lei Huo, Jingbo Zhang, Jianli Liu, Guixin TangarXiv 2018 · DOI · arXiv

Abstract

This study presents a refined method for extracting the spatial image of pion-emitting sources in high-energy heavy-ion collisions. By analyzing particle correlations in the Source Center-of-Mass Frame (CMFS) and applying a selective energy-difference cut ($\Delta E < 10$ MeV), the researchers successfully mitigate the "duration effect" that typically blurs such reconstructions. Validation against both toy models and realistic AMPT simulations demonstrates that this technique provides a highly accurate, undistorted physical picture of the source geometry.

Introduction: The Challenge of Source Imaging

In high-energy physics, Hanbury-Brown-Twiss (HBT) interferometry is a vital tool for probing the femtometer-scale "fireballs" created in heavy-ion collisions. Traditionally, source functions $S(r)$ are extracted in the Center-of-Mass Frame of the Pair (CMFP). However, because the CMFP varies for every particle pair, the resulting images are often physically distorted and difficult to interpret.

Moving the analysis to a fixed frame, the Source Center-of-Mass Frame (CMFS), offers a more intuitive physical perspective. The primary obstacle is the "duration effect": the interference term $\Delta E \Delta t$ in the correlation function blurs the spatial image when the emission time difference $\Delta t$ is non-zero.

Methodology: Selective Data Filtering

The authors propose a straightforward solution: building the correlation function using only identical pion pairs with a very small energy difference. By enforcing a cut of $\Delta E < 10$ MeV, the problematic $\Delta E \Delta t$ term becomes negligible. This allows for the use of simplified imaging equations—originally designed for the CMFP—within the fixed CMFS frame. The spatial distribution is then obtained through a model-independent Fourier transform imaging technique.

Results and Discussion

The effectiveness of the energy cut is clearly demonstrated in Figure 4. Without the cut ("all pairs"), the reconstructed source function significantly deviates from the true model source, especially at larger distances. As the energy cut is tightened from 30 MeV to 10 MeV, the reconstruction converges toward the real source function, effectively eliminating the distortion caused by the emission duration.

Figure 4: Comparison of reconstructed source functions with different energy-difference cuts against the true model source. The tighter cut provides a significantly more accurate match.

The method was further validated using the "A Multi-Phase Transport" (AMPT) model for Au+Au collisions at $\sqrt{s_{NN}} = 200$ GeV. As shown in Figure 6, the technique remains robust across different collision geometries, from central ($b=0$ fm) to peripheral ($b=10$ fm) collisions. In all cases, the reconstructed source function (dotted points) closely follows the actual model source (solid line), accurately capturing the physical scale of the emitting region.

Figure 6: Reconstructed source functions for Au+Au collisions at different impact parameters using the AMPT model. The method accurately recovers the source function across varying collision centralities.

A key advantage of the CMFS approach is its reduced sensitivity to the particles' momentum distribution compared to CMFP analysis. Furthermore, the CMFS imaging correctly identifies the physical boundaries of the source, showing the function dropping to zero beyond the actual diameter (approx. 20-25 fm), avoiding the artificial "tails" often seen in traditional methods.

Conclusion and Future Outlook

This selective filtering technique provides a clearer, more physically grounded way to map the space-time structure of particle-emitting sources. While currently focused on one-dimensional spherical approximations, future work will aim to extend this to non-spherical geometries and incorporate corrections for final-state interactions like Coulomb repulsion. Despite the requirement for high-statistics datasets due to the strict energy cut, this method represents a significant step forward in high-energy nuclear imaging.

Summary updated

Abstract

In this paper, we try a method to extract the image of pion-emitting source function in the center-of-mass frame of source (CMFS). We choose the identical pion pairs according to the difference of their energy and use these pion pairs to build the correlation function. The purpose is to reduce the effect of $\triangle E \triangle t$, thus the corresponding imaging result can tend to the real source function. We examine the effect of this method by comparing its results with real source functions extracted from models directly.
BibTeX
@misc{ren2018analysis,
  author = {Yan-Yu Ren and Qichun Feng and Wei‐Ning Zhang and Lei Huo and Jingbo Zhang and Jianli Liu and Guixin Tang},
  title = {{Analysis of the image of pion-emitting sources in source center of mass frame}},
  year = {2018},
  eprint = {1806.05061},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/1806.05061},
}
Figure