Analysis of the environmental magnetic noise rejection by using two simple magnetoelectric sensors

Yi Shen, Junqi Gao, Liang Shen, David Gray, J Li, Peter Finkel, D. Viehland, Xin Zhuang, S. Saez, Christophe DolabdjianSensors and Actuators A Physical 2011 · DOI

TL;DR

This paper presents a method for rejecting environmental magnetic noise using two simple magnetoelectric (ME) sensors in a differential configuration. By subtracting the signals from two closely spaced ME sensors, the researchers demonstrate a significant reduction in ambient magnetic noise, paving the way for more sensitive magnetic sensing in unshielded environments.

What Problem Does This Paper Address?

Magnetic sensors are crucial for a wide range of applications, but their performance is often severely hampered by environmental magnetic noise. This noise, originating from sources like power lines, electronic devices, and even natural geomagnetic fluctuations, can easily overwhelm the faint signals that many sensors are designed to detect. While magnetic shielding can mitigate this issue, it's often impractical or impossible in many real-world scenarios, especially for portable or large-scale systems. The challenge, therefore, is to find effective ways to reject this pervasive environmental noise without compromising the sensor's intrinsic sensitivity or requiring bulky shielding. This paper specifically addresses the need for a practical and effective noise rejection technique for magnetoelectric sensors, which offer advantages like room-temperature operation and high sensitivity.

Methods

The core of the proposed method relies on a differential measurement technique using two identical magnetoelectric (ME) sensors. These sensors, described as tri-layer Metglas/PZT/Metglas laminates, are configured in a parallel array with a small baseline (10 cm). The key idea is that environmental magnetic noise, being spatially homogeneous over short distances, will affect both sensors similarly. By subtracting the output signals of the two sensors, this common-mode noise is effectively canceled out.

The experimental setup involved:

  • ME Sensors: Two custom-built ME laminate sensors, each consisting of magnetostrictive Metglas layers coupled to a piezoelectric PZT fiber bundle.
  • Charge Amplifiers (CAs): Each sensor was connected to a battery-operated charge amplifier with a specific transfer function and frequency bandwidth.
  • Data Acquisition: A CR5000 Datalogger was used to record the amplified sensor signals at a 100 Hz sample rate.
  • Signal Processing: MATLAB scripts were employed for post-processing, including calculating the differential signal and analyzing power spectral densities and coherence.

The authors also employed classical signal processing techniques to analyze the noise, including:

  • Power Spectral Density (PSD): To quantify the noise levels of individual sensors and the differential output.
  • Coherence: To assess the degree of correlation between the signals from the two sensors, which is crucial for effective common-mode rejection.

Datasets

Not discussed in the paper. The experiments were conducted in a laboratory environment, and the data generated was specific to the experimental setup and conditions.

Key Insights and Ideas

  • Differential Measurement as a Powerful Noise Rejection Tool: The fundamental insight is that by exploiting the spatial homogeneity of environmental magnetic noise, a simple differential subtraction of signals from two closely spaced sensors can achieve significant noise reduction. This is a well-established concept but its application to ME sensors in this manner is highlighted.
  • Coherence is Key to Rejection Efficiency: The paper emphasizes that the effectiveness of the differential rejection is directly related to the coherence between the two sensor signals. High coherence indicates that the noise is indeed common-mode and can be effectively canceled.
  • Intrinsic Sensor Noise and Discrepancies Limit Rejection: While the differential technique effectively rejects external noise, the ultimate limit of rejection is determined by the intrinsic incoherent noise of each sensor and any discrepancies (e.g., slight differences in gain or phase response) between them.
  • ME Sensors are Promising for Gradiometry: The results suggest that ME sensors, due to their sensitivity and the demonstrated noise rejection capability, are well-suited for developing gradiometers, which are designed to measure spatial gradients of magnetic fields.

Key Results

  • Significant Noise Reduction: The differential configuration achieved an equivalent magnetic noise floor that was approximately 20 times lower than that of individual sensors.
  • Intrinsic Noise Floor: The intrinsic noise floor of the individual ME sensors was measured to be around 20 pT/√Hz in a magnetically shielded environment.
  • Rejection Factor: The system demonstrated a rejection factor of approximately 20 for external coherent noise sources.
  • Coherence: The coherence between the two sensor signals was found to be close to 1 across the measured frequency range, indicating strong correlation of the environmental noise.
  • Phase Shift Impact: A small phase shift between the sensors was identified as a limiting factor in the rejection efficiency, contributing to a residual noise level.

Limitations and Future Work

  • Limitations:
    • The study focused on a laboratory environment and did not consider the full range of real-world environmental disturbances.
  • The rejection efficiency was limited by the intrinsic incoherent noise and phase shift discrepancies between the individual ME sensors.
  • The dynamic range and spatial rejection capabilities were not fully explored.
  • Future Work:
    • Further investigation into optimizing the ME sensors to lower their intrinsic noise and minimize phase shift discrepancies.
  • Characterizing the differential measurement as a gradiometric measurement to define the limits of the current design.
  • Exploring the application of this technique in more complex and challenging environments.
  • Developing more advanced signal processing techniques to further enhance noise rejection.

Summary updated

BibTeX
@inproceedings{shen2011analysis,
  author = {Yi Shen and Junqi Gao and Liang Shen and David Gray and J Li and Peter Finkel and D. Viehland and Xin Zhuang and S. Saez and Christophe Dolabdjian},
  title = {{Analysis of the environmental magnetic noise rejection by using two simple magnetoelectric sensors}},
  booktitle = {Sensors and Actuators A Physical},
  year = {2011},
  doi = {10.1016/j.sna.2011.08.013},
}
Figure